Hasselblad 10026 service manual Circuit board 22575 *22882, Front bayonet plate

Page 10

3:2

Camera body 503CW

Disassembly

Circuit board (22575) *22882

CAUTION! When handling the circuit board a grounded bench mat and a wrist strap must be used to prevent ESD damage.

Lift the chassis connector out of the hole in which it is seated in the left hand wall. Remove the two screws (820325) that secure the photodiode. Gently ease the photodiode through the hole in the left wall.

Remove the two screws (820011) and the grounding attachment (22453). Remove the screw (820011) and the cable holder (12453). Remove the two screws (820015) and separate the circuit board from the chassis.

Finally, remove the insulating plate (22746).

* Note! The circuit board (22882) is fixed to the wall by an

 

insulating double-sided tape, screws and attachment.

Fig. 3

Fig. 3.

 

Front bayonet plate (30777)

Disconnect the spring (814512) from the push rod (22369). Remove the release bar (30375) by gently lifting it with a screwdriver so that it is freed from the front gear wheel and then easing it forward.

Remove the front bayonet plate (30777) by removing two screws (820015) in each of the right and left sides, two (821017) in the view finder screen frame and two (823655) in the bottom plate. Carefully draw the front plate forward. Fig. 4.

Note! The drive spring should be held when the gear wheel is released to prevent damage to the drive spring by releasing the tension too quickly.

821017

820015

823655

Fig. 4

Rear plate (30300) (including auxiliary shutter)

Disconnect the arm (22781) secured to the mirror frame by a clip (817115). Remove the washer (810649) underneath the arm. Remove two screws (821017) on top of the focusing screen frame and six (820015) then partly withdraw the rear plate. When partly removed, disconnect both the upper and lower connecting rods. The rear plate can now be removed completely.

Fig. 5.

Fig. 5

Revision 2

May 2000

Image 10
Contents Victor Hasselblad AB Göteborg SwedenContents list Camera body 503CW Fitted with wrong spacers 503C/M and 503CX Updated pages 503CXiSignal arm shortened 501C and 503CXi Flash metering circuit redesigned 503CX04/01 New CD-ROM Version General description Camera typeRelease sequence Tool No Description Tools Used forTool No Description Used for Camera shell Front bayonet plate Circuit board 22575 *22882Rear plate 30300 including auxiliary shutter Right hand wall Focusing screen frameMechanism plate Gear housing Reassembly 816802 Fitting the mechanism plate to the right hand wall 821631 13108 814827 13355 13280 13362 Rear plate Front plate Perform the necessary adjustment as described in sectionIntermediate gear Adjustment Adjustment of the front key’s angular position Focal lengthAngle 15-16 o with the bayonet plate tool 904644 pushed Adjustment of the release mechanism 15 mm Adjustment of the release sequence Fitting the damping ring Adjustment Fitting the camera body into the shell Fitting the Circuit board 22575 *22882Final checks 510 Camera body 503CW 511 Camera body 503CW 512 Camera body 503CW 513 Camera body 503CW Front plate reassembly Front gearFront bayonet plate Exchanging the mirror Exchanging the auxiliary shutterShim washers Revision May Pos Pcs Spare Description Remark May Camera body 503CW Camera body 503CW Camera body 503CW September Camera body 503CW Camera body 503CW Camera body 503CW Camera body 503CW Camera body 503CW October May Camera body 503CW Camera body 503CW 151 Spare parts not listed are the same as for 503CW 152 152 153 153 154 154 155 Coupling Crank support 161 Pos Pcs No Spare Part No Description Remark 162 Pos Pcs Spare Description Remark 163 163 171 171 172 172 173 173 174 174 175 175 181 181 182 182 183 183 184 184 185 January 191 October 192 192 193 193