JVC GY-DV5001 manual Indications on the LCD Monitor and in the Viewfinder Cont’d

Page 22

2. CONTROLS, INDICATORS AND CONNECTORS

2-6 Indications on the LCD Monitor and in the Viewfinder (Cont’d)

Status 1

In addition to the information on the Status 0 screen, this screen displays the following items.

No.

Item

 

 

Contents

 

 

 

 

 

 

0

Time Code (TC)/User’s Bits (UB) indication

Indicates the time code (h:m:s:frame) or user’s bits data.

 

 

 

(Example) Time code

TC 00 : 00 : 00 : 00

 

 

 

 

 

User’s bits

UB FF EE DD 20

 

 

 

 

Whether or not to display this item is set with the TC/UB item on the LCD/

 

 

VF (2/2) menu screen. Whether the time code or user’s bits should be

 

 

shown is selected with the COUNTER switch inside the side cover.

A

Remaining tape indication

Remaining tape indication (displayed in 1-minute steps)

 

 

 

This indicator blinks when remaining tape time is equivalent to less than 3

 

 

minutes.

 

 

 

 

 

Whether or not to display this item is set with the TAPE REMAIN item on

 

 

the LCD/VF (2/2) menu screen.

 

 

 

 

* When inserting a brand-new tape, the remaining tape time is not indicated.

 

 

When the tape has been run, the indication will appear.

 

 

 

* The remaining tape indication is to be regarded only as a guide.

 

 

* When the unit is used at low temperatures, it may take a while before the

 

 

indication of the remaining tape time appears.

 

 

 

 

 

B

Audio sampling frequency indication

32 K : Indicated when the AUDIO MODE item on the AUDIO menu screen

 

 

 

is set to 32 K. (Audio is recorded with 12-bit, 32 kHz sampling.)

 

 

48 K : Indicated when the AUDIO MODE item on the AUDIO menu screen

 

 

 

is set to 48 K. (Audio is recorded with 16-bit, 48 kHz sampling.)

C

Audio level meter indication

Displays the CH-1, CH-2 audio level meters.

 

 

 

 

Whether or not to display this item is set with the AUDIO item on the LCD/

 

 

VF (2/2) menu.

 

 

 

 

 

 

 

 

D

VTR mode indication

STBY

: In record standby mode (record-pause mode)

 

 

 

REC

: During recording

 

 

 

 

ED.FWD : Edit search in forward direction

 

 

 

 

ED.REV : Edit search in reverse direction

 

 

 

 

PLAY

: During playback

 

 

 

 

FF

: During fast forward

 

 

 

 

REW

: During rewind

 

 

 

 

STL

: During still picture playback mode

 

 

 

 

BSRH

: During blank search

 

 

 

 

FWD

: During playback in forward direction (FWD1: About 5 speed,

 

 

 

FWD2: About 10 speed, FWD3: About 20 speed)

 

 

 

REV

: During playback in reverse direction (REV1: About 5 speed,

 

 

 

REV2: About 10 speed, REV3: About 20 speed)

 

 

 

STOP

: Stop mode (Tape protect mode)

 

 

 

 

EJECT

: Cassette being ejected

 

 

 

 

– – –

: No tape loaded

 

 

E

Iris indicator display

: Iris set higher than normal

 

 

 

 

: Iris set to normal

 

 

 

 

 

: Iris set lower than normal

 

 

F

Iris F-value indication

Indicates the F-number of the connected lens.

 

 

 

 

OPEN, F2, F2.8, F4, F5.6, F8, F11, F16, CLOSE

 

 

 

 

It is not displayed when the lens is removed. For some lenses, no display

 

 

appears.

 

 

 

 

 

The indication can be switched ON/OFF with the F.NO/IRIS IND. item on

 

 

the LCD/VF (1/2) menu screen.

 

 

 

 

 

 

 

G

Filter position indication

Indicates the current filter position

 

 

 

 

FIL1, FIL2, FIL3, FIL4

 

 

 

 

 

The indication can be switched ON/OFF with the FILTER item on the LCD/

 

 

VF (1/2) menu screen.

 

 

 

 

 

 

H

Standard audio level indication

The level at which audio is recorded on the tape is indicated by “”.

 

 

–20dB, –12dB

 

–20dB –12dB

 

 

See “AUDIO REF. LEVEL” on page 74.

 

 

 

 

CH 1

■ ■

 

 

 

 

 

CH 1 ■ ■■ ■ ■ – – – +

 

 

 

 

CH 2 ■ ■■ ■ ■ – – – +

 

 

 

 

 

 

 

E-22

Image 22
Contents GY-DV5001MANUEL D’INSTRUCTIONS Instrucciones Istruzioni LWT0074-001C-HPort Cable Length DV signal input is possible with the GY-DV5001EThese instructions are for the GY-DV5000E and GY-DV5001E Rating plate serial number plate is on the top frame Main Features AC Operation Battery Pack Operation Optional Main FeaturesConnecting a Video Component with DV Connector 11-11Precautions for Proper Use IntroductionHead cleaner Tape guides & rollers Routine and Periodical MaintenancePrecautions for Use of Head Cleaning Tape Time managementVideocassette to be Used Battery Pack to be UsedUse JVC’s videocassette tapes marked with the or Symbol For recording and storing videotapes in the best conditionSmear and Blooming Characteristic CCD PhenomenaCondensation Moire or AliasingCONTROLS, Indicators and Connectors Front SectionLens mounting ring/Lens lock lever Auto WHITE/ACCU Focus switchFilter Colour temperature conversion filter control knob White BalanceRight Side Section VTR VTR mode indicator Black Black stretch/black compression switchCAM Camera mode indicator Power Power ON/OFF switchRight Side Section Cont’d # Counter Counter display switch CH-1/CH-2 Audio Input CH-1/CH-2 audio input selector switch@ Monitor Select Audio monitor selector switch $ TC GENE. Time code generator setting switchC OUT Y/C output connector 4-pin Monitor OUT Monitor output connector BNCCH1/CH2 Line OUT CH1/CH2 line output connector RCA Left Side SectionTop Section Rear Section Battery holder lock release knob DV connectorBattery holder Breaker Breaker buttonIndications on the LCD Monitor and in the Viewfinder Camera mode Example of displayVTR mode Example of display Status ScreensStatus Screens in the Camera Mode Indications on the LCD Monitor and in the Viewfinder Cont’d Status Screen in VTR Mode Magnified Status Indications on the LCD Monitor Ntsc Inhibit Cleaning TapeHead Cleaning Required REC InhibitMenu Setting Screen Auto White Balance Indication Camera mode onlySafety Zone Indication Camera mode only TOP Menu screen Camera modeZoom Lens Optional S14 x 7.3B12U1.5-Inch Viewfinder Optional VF-P115BBasic System Connections and Adjustments Basic SystemPin Hole Attaching the Zoom LensAttaching the Viewfinder ViewfinderAttaching the Microphone Provided Attaching the Microphone Using KA-A50UAttaching the Microphone Optional Tripod mounting holes Front mount clip Safety lever Lock leverAttaching the Tripod Base Provided Front base mountFlat shape type battery pack Anton-Bauer battery pack Power SupplyBattery Pack Operation Optional AC OperationBattery Pack Operation Optional Cont’d Using a Flat Shape Type Battery Pack optionalAttaching the Battery Pack Using an Anton-Bauer Battery PackDetaching the Battery Pack Recharging Operating Time with Battery PackBattery Pack Continuous Operating Time at 25 ˚C SonyMode Operation Turning the Power onTurning the Power OFF PreparationsREC Save Cassette Loading and UnloadingLoading the Cassette VTROpen knob Unloading the CassetteCassette cover Eject button Opening the LCD monitor Adjusting the LCD monitorViewing the LCD Monitor Changing the orientation and angle of the LCD monitorDial Setting, Displaying and Recording the Date and TimeSetting the Date and Time MenuSetting, Displaying and Recording the Date and Time Cont’d Clock Adjust menu screen Date Year/Month/DayDisplaying the Time and Date on the Screen Recording the Date and Time DataHow to charge Charging the Built-in BatteryAC outlet AA-P250 DC cable Filter Camera SettingsScreen Size 43/LETTER Mode Selection Suitable LocationAdjust the position and angle of the viewfinder Viewfinder AdjustmentExternal Monitor Adjustment Colour video monitorBack Focus Adjustment Accu Focus can also be used in the above stepWhite Balance Adjustment Line Audio Input Signal SelectionMIC Auto mode is selected in the Full Auto shooting mode Recording Level AdjustmentUsing the audio input level control on the front section Monitor Select switch Monitoring Audio during RecordingShooting Operation Basic Recording OperationAbout the Quick REC Start Mode When it is required to unload the videocassetteWhen the power should be turned off Tally lampScreen indications during Edit Search Searching for Recorded Scenes Edit SearchEdit Search Searching the tape in forward directionIf the Record-Standby Mode Continues Setting the time before the tape protection mode is EngagedHeader REC Function Header REC menu screen contentsDescription Executing the Header REC Function How to set the Header REC menu screenDuring Header REC Colour bar signal of the built-in signal generator Output switchRecording the Colour Bars Power switch Mode switch Playback ModePlayback Procedure Display of time codeSearch Fast-Forward, RewindBlank Search Outputting CH-3, CH-4 Channel Audio SettingVTR indicator Shutter dial Status button TOP Menu screenConnecting a Video Component with DV Connector Using External ComponentsDV connector DV cable VC-VDV204 4P-4P, VC-VDV206 4P- 6P Date and time data SettingsOperation Connections Data transmitted from the playback unit is recordedTime Code Operation Presetting and Recording of Time CodeTC GENE. switch Displaying Time CodeZero-resetting the Time Code or User’s Bit Data Time code hour, min, sec, frameReproducing Time Codes Set the TC Gene switch inside the cover on the side toTC Gene switch Regen11-1Menu Screen Configuration Menu ScreensShutter STA 11-2Setting Menu ScreensStatus button Termenu dial Cursor Menu screenResetting the Menu Settings to the Factory Settings Storing Setting ValuesReading Out a Menu Settings File 11-3FILE Manage Menu Screen11-4TOP Menu Screen 11-5CAMERA Operation Menu Screen 11-6CAMERA Process Menu Screen 11-8SKIN Color Adjust Screen 11-7ADVANCED Process Screen11-9AUDIO Menu Screen 11-10 LCD/VF Menu Screen 11-10 LCD/VF Menu Screen Cont’d 11-11 TC/UB/CLOCK Menu Screen Header REC Menu Screen TIME/DATE Menu Screen Others Menu Screen Type Alarm VRBattery FrontWHT.BAL switch Features of the Camera SectionSetting procedure Full-Time Auto White Balance FAWManual adjustment Iris Brightness AdjustmentAutomatic adjustment Temporary auto iris adjustmentShutter STA TER Adjusting the Shutter SpeedOperation Set the Shutter item on the Camera Operation menu screenBand Video monitor Shooting the Screen Image on a Computer Monitor Variable Scan V.SCAN Basic operationSwitch Position Factory-Set Gain Gain Sensitivity AdjustmentGain switch Relationship between gain, iris and shutterSwitch Setup According to Illumination and Subject Automatic Setting ContentsDetection How to Use Skin DetailSetting the Color and Range of the Skin Detail Function AreaStatus Using the Skin Detail FunctionDisplay Screen indications on the LCD monitor and in the Viewfinder Alarm Indications and ActionsOthers Indication Condition RemedyBlinking Pattern Remaining Battery/Tape Error Code Error Details GY-DV5000 Operation RemedyTally lamp Alarm Sound Alarm Indications and Actions Cont’dCamera to operate REC/ALARM lamp Battery lamp Viewfinder Warning LampsTape. See Precautions for Use of Head Cleaning Tape on TroubleshootingSymptoms Remedy TypeOthers 2/2 menu screen Hour Meter DisplayShutter dial Status button Accumulated drum running timeSpecifications Viewfinder VF-P115B, VF-P116 Power zoom lens Specifications Cont’dExternal Dimensions unit mm YH16 ⋅ 7K12U, YH19 ⋅ 6.7K12U CanonGY-DV5000/GY-DV5001 DV Camcorder