How to adjust

Flange back adjustment (for zoom lens)

The adjustment is to adjust the focus in all the range from the maximum zoom to the widest angle of the zoom lens.

Shoot a dark object to open the iris.

Adjust the distance from the object to 6.6 ft. (2 m) at least, then loosen the flange back fixing knob of the lens.

Set the lens to the maximum zoom and adjust the focus by turning the focus ring.

Set the lens to the widest angle and adjust the focus by turning the flange back adjust ring.

Repeat adjusting the focus ring and flange back adjust ring until the focus is adjusted within the zooming range.

After finishing the adjustment, tighten the flange back fixing knob.

ENGLISH

Focus ring

Flange back fixing knob

Flange back adjust ring

Lens iris gain volume adjustment

Iris gain adjust hole (G or S) is provided at front of the lens housing. Adjust the iris according to the following procedure by using a screwdriver.

Set the iris select switch of the lens to A “AUTO” side.

Turn the iris gain adjust volume to maximize the gain in such extent that no hunting takes place.

*When CAM is selected as the IRIS MODE setting on the camera menu, IRIS gain on the menu can be used to make adjustments.

Iris gain adjust volume

Auto iris power zoom lens

- 16 (E) -

Image 17
Contents Multi Purpose Camera AK-HC1500GFCC Note English VersionEnglish Important Safety Instructions For business users in the European Union Accessories ContentsIntroduction Characteristics Cooling fan Precautions for useBottom view Rear view Front viewMajor operating controls and their functions  HD SDI output connector HD SDI OUT  Tally output connector Tally OUT Iris control cable to Iris connector How to set the lensConfiguration example 1 Connection of camera controller How to set up the systemConfiguration example 2 High-Speed P/T system Adjust the white balance Operation procedureAdjust the black balance Start shootingFlange back adjustment for zoom lens How to adjustLens iris gain volume adjustment Auto iris power zoom lensColor temperature and white balance adjustment reference White balance adjustmentGen-lock adjustment Black balance adjustmentHow to display the menus Setting of menu items Using AK-HRP150G camera controller TOP menuBlack Shading  Maintenance menuDetection READY, Active Correctdig OFF, onGamma PEDESTAL, GammaBlack Gamma OFF, on Gamma OFF, onDRS OFF, on Cine Gamma Select Video REC, Film RECFlare OFF, on FlareFlare 000 to Knee Point KNEE, White Clip80.00% to 107.00% Video Menu 30% to 90% Film MENU/VIDEO REC Knee Point -25.00% to +25.00%White Clip LVL 90% to 109% Knee Point 80.00% to 107.00%Knee Level 100% to 109% Knee OFF, MANUAL, Auto B GainWhite Clip OFF, on High Color OFF, onKnee Aperture OFF, on DetailDetail OFF, on Detail Source Slim Detail OFF, onSkin GET OFF, on Skin Tone DetailSkin Tone DTL OFF, on GAIN, Auto Iris Iris Mode LENS, CAMIris Level 0 to Iris PEAK/AVE 0 toSuper Gain Mode S.GAIN1, S.GAIN2, S.GAIN3PED Offset -200 to +200 Peak Frequency 0 to35 to 0.75 DRS OFF -10 to +10 DRS on Frame Rate 60 to Frame ModeFrame Rate Range 60-6 Matrix Table A, B MatrixColor Correction Mode  Setting menuGain Select LOW, MID, HIGH, S.GAIN1 toColor Correction OFF, on Matrix Table OFF, A, BDigital Extender OFF, on BAR SELStatus OFF, on FormatAWB Active AWB OKOUT Range RGB ABB OKMenu on BAR OFF, on FAN OFF, AUTO, onSynchro Scan ShutterShutter Speed PIX Defect GEN-LOCKGEN-LOCK Input BNC, Dsub Auto DetectionProtocol 1 to Protocol Camera ID menu  File Operation menu Mode LOAD/STORELOAD/STORE from Execute Time Code menu ResetPreset Menu list 47 E 48 E Unit inch mm AppearanceInput/output signal SpecificationsControl cable for information camera Appendix