Major operating controls and their functions
Tally output connector [TALLY OUT]
The R tally and G tally signals are output from this connector.
These signals take effect when the optional card for studio applications has been inserted.
Pin No. | Signal |
1 | GND |
2 | R_TALLY_OUT |
3 | G_TALLY_OUT |
4 | +12 V (500 mA Max) |
IRIS connector [IRIS]
Used to connect the IRIS control cables of the lens.
Pin No. | Signal | Pin No. | Signal |
1 | Return control | 7 | Iris follow |
2 | 8 | Iris auto selection | |
3 | UNREG GND | 9 | — |
4 | Iris manual selection | 10 | Zoom position information |
5 | Iris control | 11 | Focus position information |
6 | UNREG 12 V | 12 | NC |
Zoom/Focus connector [ZOOM/FOCUS]
Used to connect the zoom/focus control cables of lens.
Pin No. | Signal | Pin No. | Signal |
1 | Focus control selection | 7 | COM |
2 | Zoom control selection | 8 | Focus control |
3 | GND | 9 | Zoom control |
4 | Forcible iris closing | 10 | Iris control selection |
5 | Iris control | 11 | COM +Voltage |
6 | +Voltage | 12 | COM |
Operate indicator
Green LED lamp lights to indicate that the specified DC power is supplied to the DC 12 V input connector .
When the video format is changed, the operate LED flashes twice when the format is 720/60p and once with any other format.
DC 12 V input connector [DC12V IN]
12 V DC is supplied through the optional DC power supply cable
- 11 (E) -