Axis Communications Q6034 user manual Image Settings, Go to Video & Audio Overlay Image

Page 20

AXIS Q6034 PTZ Dome Network Camera

Video and Audio

Image Settings

Autofocus enabled - Automatic focusing is enabled by default. If the focus position is changed manually using the focus bar, autofocus will be disabled even if enabled here. In this case, use the PTZ control panel to enable autofocus, see PTZ Controls, on page 11. If required, the focus control can be disabled under PTZ > Advanced > Controls.

Image freeze on PTZ - Select All movements to freeze the image while the camera is moving during a pan, tilt or zoom operation. Once the camera reaches its new position, the view from that position is shown. Presets freezes the image only when the camera moves between preset positions.

Overlay

Overlays are used to provide extra information, for example for forensic video analysis or during product installation and configuration. Overlays are superimposed over the video stream.

An overlay text can display the current date and time, or a text string. When using a text string, modifiers can be used to display information such as the current bit rate or the current frame rate. For information about available modifiers, see File Naming &

Date/Time Formats in the online help .

To enable overlays:

1.Go to Video & Audio > Video Stream and select the Image tab.

2.To include an overlay image, select Include overlay image at the coordinates. The overlay image must first be uploaded to the Axis product, see Overlay Image.

3.To include date and time, select Include date and Include time.

4.To include a text string, select Include text and enter the text in the field. Modifiers can be used, see File Naming &

Date/Time Formats in the online help .

5.Select the text color, the text background color and the position of the overlay.

6.Click Save.

To modify the date and time format, go to System Options > Date & Time. See Date & Time, on page 42.

Overlay Image

An overlay image is a static image superimposed over the video stream. The image, for example company logo, is used to provide extra information or to mask a part of the image.

Since it is static, the position and size of an overlay image will remain the same regardless of resolution and Pan/Tilt/Zoom movements. To set up a dynamic mask, which will always mask the specified part of monitored area, see Privacy Mask.

To use an overlay image, the image must first be uploaded to the Axis product:

1.Go to Video & Audio > Overlay Image.

2.Click Browse and browse to the file.

3.Click Upload.

4.Select the image to use from the Use overlay image list.

5.Click Save.

To display the overlay image:

1.Go to Video & Audio > Video Stream and select the Image tab.

2.Under Overlay Settings, select Include overlay image at the coordinates and enter the X and Y coordinates.

20

Image 20
Contents Axis Q6034 PTZ Dome Network Camera Safety About this DocumentLiability Intellectual Property RightsLearn More Table of Contents Axis Q6034 PTZ Dome Network CameraSymptoms, Possible Causes and Remedial Actions Connectors Hardware OverviewHardware Overview For technical specifications, seeColor Indication LED IndicatorsMidspan LED Indicators Accessing the Product Accessing the ProductAccess from a Browser Start a browser Internet Explorer, Firefox, SafariAccess from the Internet Set the Root PasswordNetwork TCP/IP Advanced Click Create self-signed certificateAxis Media Control viewer toolbar Live ViewControls on the Live View PTZ Controls AMC Audio ControlsAxis Q6034 PTZ Dome Network Camera How to Stream H.264 Media StreamsMedia Streams Axis Media Control AMCAlternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAccessing Audio Streams Java applet supports simplex audio with G.711 encodingBasic Setup Setting Up the ProductSetting Up the Product Video and Audio Video and AudioVideo Stream Pixel CounterClick Save to apply the new settings Stream ProfilesImage 264Camera Settings Exposure SettingsImage Appearance White BalanceImage Settings OverlayOverlay Image Go to Video & Audio Video Stream and select the Image tabAudio Settings Privacy MaskAudio Modes Audio InputG711 G726 Audio ClipsAudio Output Axis Q6034 PTZ Dome Network Camera Live View Config Default Viewer for BrowsersLive View Config Viewer Settings Go to Setup Live View ConfigUser Defined Links Output ButtonsAxis Q6034 PTZ Dome Network Camera Preset Positions PTZ Pan Tilt ZoomPTZ Pan Tilt Zoom AutotrackingMax Limits ConfigurationExclude Areas Gatekeeper Guard TourOsdi Zones AdvancedTour Recording LimitsControls Operator Same as administrator but with lower priorityControl Queue Set Up Motion Detection Windows DetectorsDetectors Motion DetectionAudio Detection Motion Detection ParametersApplications ApplicationsEvents EventsSetting Up an Action Rule Convert Event Types to Action RulesPTZ Control Go to Events Action Rules and click AddRecipients SchedulesRecipient Use with action Go to Events Recipients and click AddRecurrences Go to Events Recurrences and click AddRecordings RecordingsRecording List Continuous RecordingAxis Q6034 PTZ Dome Network Camera System Options System OptionsSecurity UsersAudio Support Date & TimeIeee Basic TCP/IP Settings NetworkIPv4 Address Configuration IPv6 Address ConfigurationAdvanced TCP/IP Settings Link-Local IPv4 Address NAT traversal port mapping for IPv4QoS Quality of Service Smtp emailStorage UPnPTMRTP/H.264 BonjourPorts & Devices Network SharePorts Go to System Options Storage Click Network ShareMaintenance SupportReset to Factory Default Settings ScriptingFile Upload Plain Config192.168.0.90 Troubleshooting TroubleshootingEmergency Recovery Procedure Checking the FirmwareProduct cannot be accessed from a browser Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product is accessible locally but not externally Problems with the H.264 formatVideo and image problems, general Setup Video & Audio Camera SettingsNo images displayed on web Overlay image is not displayedProblems uploading files SettingsStorage and disk management problems Motion Detection triggers unexpectedlyTechnical Specifications Technical SpecificationsInstallation aid MaintenancePower ConnectorsMulti-Connector Cable sold separately Function Pin Specifications To +40 V DCMax voltage = +40 V DC With the load, for protection against voltage transientsPerformance Considerations Connection diagramDC power input Axis Q6034 PTZ Dome Network Camera M1.6