Axis Communications Q6034 Function Pin Specifications, To +40 V DC, Max voltage = +40 V DC

Page 60

AXIS Q6034 PTZ Dome Network Camera

Technical Specifications

Function

Pin

Notes

Specifications

 

 

 

 

GND

1

Ground

 

 

 

 

 

3.3 V DC Power

2

Can be used to power auxiliary equipment.

Max load = 250 mA

 

 

Note: This pin can only be used as power out.

 

 

 

 

 

Configurable

3–6

Digital input — Connect to GND to activate, or leave floating

0 to +40 V DC

(Input or Output)

 

(unconnected) to deactivate.

 

 

 

Digital output — Internal connection to ground when

Max load =100 mA

 

 

activated, floating (unconnected) when deactivated. If used

Max voltage = +40 V DC

 

 

with an external relay, a diode must be connected in parallel

 

 

 

with the load, for protection against voltage transients.

 

 

 

 

 

60

Image 60
Contents Axis Q6034 PTZ Dome Network Camera Safety About this DocumentLiability Intellectual Property RightsLearn More Table of Contents Axis Q6034 PTZ Dome Network CameraSymptoms, Possible Causes and Remedial Actions Connectors Hardware OverviewHardware Overview For technical specifications, seeLED Indicators Midspan LED IndicatorsColor Indication Accessing the Product Accessing the ProductAccess from a Browser Start a browser Internet Explorer, Firefox, SafariAccess from the Internet Set the Root PasswordNetwork TCP/IP Advanced Click Create self-signed certificateLive View Controls on the Live ViewAxis Media Control viewer toolbar PTZ Controls AMC Audio ControlsAxis Q6034 PTZ Dome Network Camera How to Stream H.264 Media StreamsMedia Streams Axis Media Control AMCAlternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAccessing Audio Streams Java applet supports simplex audio with G.711 encodingSetting Up the Product Setting Up the ProductBasic Setup Video and Audio Video and AudioVideo Stream Pixel CounterClick Save to apply the new settings Stream ProfilesImage 264Camera Settings Exposure SettingsImage Appearance White BalanceImage Settings OverlayOverlay Image Go to Video & Audio Video Stream and select the Image tabAudio Settings Privacy MaskAudio Modes Audio InputAudio Clips Audio OutputG711 G726 Axis Q6034 PTZ Dome Network Camera Default Viewer for Browsers Live View ConfigLive View Config Viewer Settings Go to Setup Live View ConfigUser Defined Links Output ButtonsAxis Q6034 PTZ Dome Network Camera Preset Positions PTZ Pan Tilt ZoomPTZ Pan Tilt Zoom AutotrackingConfiguration Exclude AreasMax Limits Gatekeeper Guard TourOsdi Zones AdvancedTour Recording LimitsOperator Same as administrator but with lower priority Control QueueControls Set Up Motion Detection Windows DetectorsDetectors Motion DetectionAudio Detection Motion Detection ParametersApplications ApplicationsEvents EventsSetting Up an Action Rule Convert Event Types to Action RulesPTZ Control Go to Events Action Rules and click AddRecipients SchedulesRecipient Use with action Go to Events Recipients and click AddRecurrences Go to Events Recurrences and click AddRecordings RecordingsRecording List Continuous RecordingAxis Q6034 PTZ Dome Network Camera System Options System OptionsSecurity UsersDate & Time IeeeAudio Support Basic TCP/IP Settings NetworkIPv4 Address Configuration IPv6 Address ConfigurationAdvanced TCP/IP Settings Link-Local IPv4 Address NAT traversal port mapping for IPv4QoS Quality of Service Smtp emailStorage UPnPTMRTP/H.264 BonjourPorts & Devices Network SharePorts Go to System Options Storage Click Network ShareMaintenance SupportReset to Factory Default Settings ScriptingFile Upload Plain Config192.168.0.90 Troubleshooting TroubleshootingEmergency Recovery Procedure Checking the FirmwareSymptoms, Possible Causes and Remedial Actions Problems setting the IP addressProduct cannot be accessed from a browser Product is accessible locally but not externally Problems with the H.264 formatVideo and image problems, general Setup Video & Audio Camera SettingsNo images displayed on web Overlay image is not displayedProblems uploading files SettingsStorage and disk management problems Motion Detection triggers unexpectedlyTechnical Specifications Technical SpecificationsInstallation aid MaintenancePower ConnectorsMulti-Connector Cable sold separately Function Pin Specifications To +40 V DCMax voltage = +40 V DC With the load, for protection against voltage transientsConnection diagram DC power inputPerformance Considerations Axis Q6034 PTZ Dome Network Camera M1.6