Axis Communications Understanding and Configuring OSDI Zones in Your Axis Camera

Page 30

AXIS Q6034 PTZ Dome Network Camera

PTZ (Pan Tilt Zoom)

For more information see the online help .

Tour Recording

The guard tour function in this product includes tour recording, which allows recording of a custom tour using an input device such as a joystick, mouse, keyboard or through the VAPIX® Application Programming Interface (API). A recorded tour displays the video stream of the recorded sequence of Pan/Tilt/Zoom movements, including their variable speeds and lengths.

To add a recorded tour:

1.Go to PTZ > Guard Tour and click Add.

2.Select Create a record tour and click OK.

3.Enter a descriptive name.

4.Specify the pause length between runs.

5.Click to start recording the Pan/Tilt/Zoom movements.

6.When satisfied, click.

7.Click OK.

Note

Only the name of the recorded tour and pause between runs can be modified. Starting a new recording will overwrite the existing guard tour.

The recorded tour can be activated from the Live View and Guard Tour pages or through events. For more information see

the online help .

OSDI Zones

On-Screen Direction Indicator (OSDI) zones can be included in the overlay text (see Overlay, on page 20) to aid the user to navigate the Axis product. Each OSDI zone is set up with coordinates and a descriptive name.

OSDI zones are set up under PTZ > OSDI Zones. The Axis product uses the coordinates of the center of the view to set the lower left and upper right zone areas. First navigate to where you would like the lowermost left point of the OSDI zone to be located. Click Get to set the coordinates. Proceed to where the upper right point of zone should be located and click Get. Give the zone a descriptive name and click OK.

To include the name of the OSDI zone in the overlay text, go to Video & Audio < Video Stream < Overlay Settings. Check the Include text box and enter the modifier #L in the field. For more information about modifiers, see File Naming & Date/Time

Formats in the online help .

Advanced

Limits

Define the pan, tilt, zoom and focus limits for the Axis product. Movements to the left and right, up and down, can be restricted to narrow the area under surveillance.

Configure the near focus limit to avoid focusing on objects too close to the camera lens.

When Enable E-flipis selected, as it tilts down and continues to pan backwards, the Axis product will automatically correct the view and flip it 180 degrees. The left limit must be set to –180 degrees and the right limit to 180 degrees for e-flip to work.

Move speed sets the speed of the camera’s pan and tilt movements. The default setting is maximum speed.

30

Image 30
Contents Axis Q6034 PTZ Dome Network Camera Liability SafetyAbout this Document Intellectual Property RightsLearn More Table of Contents Axis Q6034 PTZ Dome Network CameraSymptoms, Possible Causes and Remedial Actions Hardware Overview ConnectorsHardware Overview For technical specifications, seeLED Indicators Midspan LED IndicatorsColor Indication Access from a Browser Accessing the ProductAccessing the Product Start a browser Internet Explorer, Firefox, SafariNetwork TCP/IP Advanced Access from the InternetSet the Root Password Click Create self-signed certificateLive View Controls on the Live ViewAxis Media Control viewer toolbar PTZ Controls AMC Audio ControlsAxis Q6034 PTZ Dome Network Camera Media Streams How to Stream H.264Media Streams Axis Media Control AMCAlternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAccessing Audio Streams Java applet supports simplex audio with G.711 encodingSetting Up the Product Setting Up the ProductBasic Setup Video Stream Video and AudioVideo and Audio Pixel CounterImage Click Save to apply the new settingsStream Profiles 264Image Appearance Camera SettingsExposure Settings White BalanceOverlay Image Image SettingsOverlay Go to Video & Audio Video Stream and select the Image tabAudio Modes Audio SettingsPrivacy Mask Audio InputAudio Clips Audio OutputG711 G726 Axis Q6034 PTZ Dome Network Camera Default Viewer for Browsers Live View ConfigLive View Config User Defined Links Viewer SettingsGo to Setup Live View Config Output ButtonsAxis Q6034 PTZ Dome Network Camera PTZ Pan Tilt Zoom Preset PositionsPTZ Pan Tilt Zoom AutotrackingConfiguration Exclude AreasMax Limits Gatekeeper Guard TourTour Recording Osdi ZonesAdvanced LimitsOperator Same as administrator but with lower priority Control QueueControls Detectors Set Up Motion Detection WindowsDetectors Motion DetectionAudio Detection Motion Detection ParametersApplications ApplicationsEvents EventsPTZ Control Setting Up an Action RuleConvert Event Types to Action Rules Go to Events Action Rules and click AddRecipient Use with action RecipientsSchedules Go to Events Recipients and click AddRecurrences Go to Events Recurrences and click AddRecording List RecordingsRecordings Continuous RecordingAxis Q6034 PTZ Dome Network Camera Security System OptionsSystem Options UsersDate & Time IeeeAudio Support IPv4 Address Configuration Basic TCP/IP SettingsNetwork IPv6 Address ConfigurationAdvanced TCP/IP Settings Link-Local IPv4 Address NAT traversal port mapping for IPv4QoS Quality of Service Smtp emailRTP/H.264 StorageUPnPTM BonjourPorts Ports & DevicesNetwork Share Go to System Options Storage Click Network ShareMaintenance SupportFile Upload Reset to Factory Default SettingsScripting Plain Config192.168.0.90 Emergency Recovery Procedure TroubleshootingTroubleshooting Checking the FirmwareSymptoms, Possible Causes and Remedial Actions Problems setting the IP addressProduct cannot be accessed from a browser Product is accessible locally but not externally Problems with the H.264 formatNo images displayed on web Video and image problems, generalSetup Video & Audio Camera Settings Overlay image is not displayedStorage and disk management problems Problems uploading filesSettings Motion Detection triggers unexpectedlyTechnical Specifications Technical SpecificationsPower Installation aidMaintenance ConnectorsMulti-Connector Cable sold separately Max voltage = +40 V DC Function Pin SpecificationsTo +40 V DC With the load, for protection against voltage transientsConnection diagram DC power inputPerformance Considerations Axis Q6034 PTZ Dome Network Camera M1.6