Bosch Appliances VEZ-400 user manual Important notices

Page 7

VEZ-400 Mini PTZ Dome

Safety en 7

 

 

1.3Important notices

CAUTION!

1.A regulated 24 VAC, 43W power supply is recommended for use with this camera for the best picture and the most stable operation. An unregulated power supply can cause damage to the camera. When unregulated power supply is applied, product warranty will be void.

2.Bosch recommends using the camera with a monitor that has a CCTV-quality 75 Ohm video impedance level. If your monitor is switched to high impedance, please adjust accordingly.

3.Do not attempt to disassemble the camera to gain access to the internal components. Refer servicing to your dealer or to qualified service personnel.

4.Never face the camera towards the sun or any bright or reflective light. This may cause smear on the picture and possible damage to the CCD.

5.Do not remove the serial sticker for the warranty service.

All-pole power switch - Incorporate an all-pole power switch, with a contact separation of at least 3 mm in each pole, into the electrical installation of the building. If it is needed to open the housing for servicing and/or other activities, use this all-pole switch as the main disconnect device for switching off the voltage to the unit.

Camera grounding - For mounting the camera in potentially damp environments, ensure to ground the system using the ground connection of the power supply connector (see section: Connecting external power supply).

Camera lens - An assembled camera lens in the outdoor housing must comply and be tested in accordance with UL/ IEC60065. Any output or signal lines from the camera must be SELV or Limited Power Source. For safety reasons, the environmental specification of the camera lens assembly must be within the environmental specification of -10 °C (14 °F) to 50 °C (122 °F).

Bosch Security Systems, Inc.

User Manual

F.01U.252.635 2.0 2011.09

Image 7
Contents VEZ-400 Mini PTZ Dome Page Table of Contents WDR/DNR Safety precautions SafetyImportant safety instructions Important notices Coax grounding Rack mount FCC & Ices Information FCC & Ices complianceModèles utilisés aux États-Unis et au Canada uniquement Informations FCC et IcesEn Safety VEZ-400 Mini PTZ Dome Disclaimer Bosch noticesTrademarks CopyrightMore information Description FeaturesUnpacking Parts ListQty Description Additional Tools Required AccessoriesModel Number Description Drawing Installation Overview Number Description Installing a Surface MountEn Installing a Surface Mount VEZ-400 Mini PTZ Dome VEZ-400 Mini PTZ Dome Installing a Surface Mount en Connection RS-485 Connections Typical wiring configurationTRX Number Signal ColorVideo Connection Alarm ConnectionsAWG Camera Settings Power Connections16AWG SW301 Rotary switch SW303 Dip switches SW302 Rotary switch No3 No4 Baud Rate bps Setting the address ID of the cameraSetting the protocol of the camera No1 No2 ProtocolCAM Test ...PASS On-Screen Display OSD MenuBasic Navigation and Common Actions VEZ-400 Mini PTZ DomeKEY Command ActionMain Menu Choices Description System SetupMain Menu Main MenuMenu Description Editing TitlesTitle System Information System Setup MenuSystem Setup Clearing Saved FunctionsSystem Information RebootReboot InitializeALL CAM Preset Tour Pattern Scan ETC Save Back PasswordInitialize Display Setup Display SetupOSD Setup PasswordPrivacy Zone OSD SetupPrivacy Zone Setup Select Privacy ZONE. The screen Privacy Zone Setup appearsPRIVACY.## Edit Display Width Height Clear Save Back Change Mirror Save Back Image SetupImage Setup Motion/Face DetectionOSD MD/FD Sensitivity Alarm Atime Save BackLanguage MOTION/FACE DetectionFocus/Zoom Camera SetupCamera Setup Select FOCUS/ZOOM. The screen FOCUS/ZOOM Setup appearsFOCUS/ZOOM Setup WB SetupFocus Zoom SPD Save Back WB Setup AE SetupMode Gain B Gain Save Back AE Mode Full Auto Manual 4 D/N SetupAE Setup Mode Shut AGC Gain AGC MAX DSS Bright Save BackAdvanced SetupDAY/NIGHT Detect Dtime Save Back Sharpness Backlight Save Select ADVANCED. The screen Advanced Setup appearsAdvanced Setup 6 WDR/DNRGeneral Setup Motion Setup Home Action Calibration Exit Dome Motion SetupWDR Setup WDR Level DNR Setup DNR Level Save Back Dome Motion SetupGeneral Setup General SetupMotion Setup Select General SETUP. The screen General Setup appearsProp PAN/TILT Auto Flip Over Tilt Save Back Select Motion SETUP. The screen Motion Setup appearsMotion Setup Home ActionHome Action Setup Select Home ACTION. The screen Home Action Setup appearsAction Number Time Mode Save Back Calibration Select CALIBRATION. The screen Calibration Setup appearsCalibration Setup Auto CAL Error MSG Disp Calibration Save BackPreset Setup Preset SetupEdit Title Time Clear Save Back Pattern Setup Pattern SetupTour Setup Tour SetupTOUR1 Preset only Save Back Change ID Change ACT Clear ID Scan Setup Scan SetupEdit Speed Dtime Direction Mode Clear Save Back Alarm Setup Alarm SetupOUT Priority Action Number Atime Save Back SET/CLEAR Problem Solution TroubleshootingVEZ-400 Mini PTZ Dome Troubleshooting en DNR Technical SpecificationsCamera Module WDRMechanical NC/NOEnvironment Dimensions Camera DimensionsBosch Protocol Preset Key Example NumberEn Bosch Protocol VEZ-400 Mini PTZ Dome Pelco Protocol Preset Key Operation Example NumberEn Pelco Protocol VEZ-400 Mini PTZ Dome Page Bosch Security Systems, Inc