Bosch Appliances VEZ-400 user manual Rack mount

Page 9

VEZ-400 Mini PTZ Dome

Safety en 9

 

 

Environmental statement - Bosch has a strong commitment towards the environment. This unit has been designed to respect the environment as much as possible. Electrostatic-sensitive device - Use proper CMOS/MOS-FET handling precautions to avoid electrostatic discharge.

NOTE: Wear required grounded wrist straps and observe proper ESD safety precautions when handling the electrostatic- sensitive printed circuit boards.

Fuse rating - For protection of the device, the branch circuit protection must be secured with a maximum fuse rating of 16A. This must be in accordance with NEC800 (CEC Section 60). Moving - Disconnect the power before moving the unit. Move the unit with care. Excessive force or shock may damage the unit and the hard disk drives.

Outdoor signals - The installation for outdoor signals, especially regarding clearance from power and lightning conductors and transient protection, must be in accordance with NEC725 and NEC800 (CEC Rule 16-224and CEC Section 60).

Permanently connected equipment - Incorporate a readily- accessible disconnect device in the building installation wiring. Pluggable equipment - Install the socket outlet near the equipment so that it is easily accessible.

Power resupply - If the unit is forced to power down due to exceeding the specified operating temperatures, disconnect the power cord, wait for at least 30 seconds, and then reconnect the power cord.

Power lines: Do not locate the camera near overhead power lines, power circuits, or electrical lights, nor where it may contact such power lines, circuits, or lights.

Rack mount

Ventilation - Do not place this unit in a built-in installation or rack without proper ventilation or adhering to the manufacturer’s instructions. The equipment must not exceed its maximum operating temperature requirements.

Mechanical loading - Properly mount the equipment in a rack to prevent a hazardous condition due to uneven mechanical loading.

Bosch Security Systems, Inc.

User Manual

F.01U.252.635 2.0 2011.09

Image 9
Contents VEZ-400 Mini PTZ Dome Page Table of Contents WDR/DNR Safety precautions SafetyImportant safety instructions Important notices Coax grounding Rack mount FCC & Ices Information FCC & Ices complianceModèles utilisés aux États-Unis et au Canada uniquement Informations FCC et IcesEn Safety VEZ-400 Mini PTZ Dome Disclaimer Bosch noticesCopyright TrademarksMore information Description FeaturesParts List UnpackingQty Description Accessories Additional Tools RequiredModel Number Description Drawing Installation Overview Number Description Installing a Surface MountEn Installing a Surface Mount VEZ-400 Mini PTZ Dome VEZ-400 Mini PTZ Dome Installing a Surface Mount en Connection RS-485 Connections Typical wiring configurationTRX Number Signal ColorAlarm Connections Video ConnectionAWG Power Connections Camera Settings16AWG SW301 Rotary switch SW303 Dip switches SW302 Rotary switch Setting the protocol of the camera Setting the address ID of the cameraNo1 No2 Protocol No3 No4 Baud Rate bpsBasic Navigation and Common Actions On-Screen Display OSD MenuVEZ-400 Mini PTZ Dome CAM Test ...PASSKEY Command ActionMain Menu System SetupMain Menu Main Menu Choices DescriptionEditing Titles Menu DescriptionTitle System Setup System Setup MenuClearing Saved Functions System InformationReboot RebootInitialize System InformationPassword ALL CAM Preset Tour Pattern Scan ETC Save BackInitialize OSD Setup Display SetupPassword Display SetupPrivacy Zone OSD SetupSelect Privacy ZONE. The screen Privacy Zone Setup appears Privacy Zone SetupPRIVACY.## Edit Display Width Height Clear Save Back Change Image Setup Image SetupMotion/Face Detection Mirror Save BackLanguage MD/FD Sensitivity Alarm Atime Save BackMOTION/FACE Detection OSDCamera Setup Camera SetupSelect FOCUS/ZOOM. The screen FOCUS/ZOOM Setup appears Focus/ZoomWB Setup FOCUS/ZOOM SetupFocus Zoom SPD Save Back AE Setup WB SetupMode Gain B Gain Save Back AE Setup 4 D/N SetupMode Shut AGC Gain AGC MAX DSS Bright Save Back AE Mode Full Auto ManualSetup AdvancedDAY/NIGHT Detect Dtime Save Back Advanced Setup Select ADVANCED. The screen Advanced Setup appears6 WDR/DNR Sharpness Backlight SaveWDR Setup WDR Level DNR Setup DNR Level Save Back Dome Motion SetupDome Motion Setup General Setup Motion Setup Home Action Calibration ExitMotion Setup General SetupSelect General SETUP. The screen General Setup appears General SetupMotion Setup Select Motion SETUP. The screen Motion Setup appearsHome Action Prop PAN/TILT Auto Flip Over Tilt Save BackSelect Home ACTION. The screen Home Action Setup appears Home Action SetupAction Number Time Mode Save Back Calibration Setup Select CALIBRATION. The screen Calibration Setup appearsAuto CAL Error MSG Disp Calibration Save Back CalibrationPreset Setup Preset SetupEdit Title Time Clear Save Back Pattern Setup Pattern SetupTour Setup Tour SetupTOUR1 Preset only Save Back Change ID Change ACT Clear ID Scan Setup Scan SetupEdit Speed Dtime Direction Mode Clear Save Back Alarm Setup Alarm SetupOUT Priority Action Number Atime Save Back SET/CLEAR Problem Solution TroubleshootingVEZ-400 Mini PTZ Dome Troubleshooting en Camera Module Technical SpecificationsWDR DNRNC/NO MechanicalEnvironment Dimensions Camera DimensionsBosch Protocol Preset Key Example NumberEn Bosch Protocol VEZ-400 Mini PTZ Dome Pelco Protocol Preset Key Operation Example NumberEn Pelco Protocol VEZ-400 Mini PTZ Dome Page Bosch Security Systems, Inc