Bosch Appliances VOT-320 manual Pan/tilt connection, Alarm inputs, Relay outputs

Page 20

20 en Installation

VOT-320

 

 

Pan/tilt connection

The pan/tilt connections are used to control a suitable Bosch pan/tilt.

Other pan/tilts may be controlled via the serial interface (see Section Data interface, page 19). The connections are located on the two 5-pin terminal blocks (see Section 8.8 Terminal blocks, page 99).

NOTICE!

The release letter for the current firmware version includes a list of compatible Bosch pan/ tilts.

CAUTION!

Please take note of the appropriate documentation when installing and operating the unit to be controlled.

The documentation contains important safety instructions and information about permitted uses.

Alarm inputs

The VOT-320 has two alarm inputs on the lower 6-pin terminal block (see Section 8.8 Terminal blocks, page 99). The alarm inputs are used to connect to external alarm devices such as door contacts or sensors. With the appropriate configuration, an alarm sensor can automatically connect the VOT-320 to a remote location, for example.

A zero potential closing contact or switch can be used as the actuator.

NOTICE!

If possible, use a bounce-free contact system as the actuator.

Connect the lines to the appropriate terminals on the lower 6-pin terminal block (IN1 and IN2) and check that the connection is secure.

Relay outputs

The VOT-320 has two relay outputs for switching external units such as lamps or alarm sirens. You can operate these relay outputs manually while there is an active connection to the VOT-320. The outputs can also be configured to automatically activate sirens or other alarm units in response to an alarm signal. The relay outputs are also located on the lower 6-pin terminal block (see Section 8.8 Terminal blocks, page 99).

CAUTION!

A maximum load of 30 Vp-p(SELV) and 200 mA may be applied to the relay contacts.

Connect the lines to the appropriate terminals on the lower 6-pin terminal block (R1 and R2) and check that the connection is secure.

DOC V4.5 2010.09

Installation and Operating Manual

Bosch Sicherheitssysteme GmbH

Image 20
Contents VOT-320 Page Table of Contents Appendix Maintenance and upgradesOperation Glossary 106 Index 111 Specifications 104Camera 104 Detector Protocols/standards 105 Preface About this manualConventions in this manual Intended useEU Directives Rating plateElectric shock hazard Safety informationInstallation and operation 3Maintenance and repair Product description Parts includedAdditional configuration requirements System requirementsGeneral requirements Additional operational requirementsOverview of functions Remote control Tamper detection and video content analysisBackup SnapshotsSummary HttpsControls and displays on the camera module Connections on the camera module 2Mounting 4Installation 1Preparations En Installation 3Connections NetworkPin EIA/TIA-568-A EIA/TIA-568-B Data interfaceRelay outputs Alarm inputsPan/tilt connection SD slot 4Power on/power offPower supply Adjusting the lens only Wfov lenses Final assembly7Setup using Bosch Video Client Installing the programAdditional parameters Configuration using a Web browser 1ConnectingInstalling Mpeg ActiveX System requirementsEstablishing the connection Maximum number of connectionsProtected network Configuration menuProtected camera Making changes Starting configurationNavigation Camera name Basic Mode Device AccessPassword Basic Mode Date/Time Confirm passwordDevice date / Device time / Device time zone Time server IP addressBasic Mode Network IP addressSubnet mask Gateway addressBasic Mode Encoder Basic Mode Recording Basic Mode System OverviewInitiator extension Advanced Mode IdentificationCamera ID Advanced Mode Password Advanced Mode Date/Time Date formatDevice date / Device time Device time zoneTime stamping Advanced Mode Display StampingCamera name stamping Advanced Mode Appearance Advanced Mode Livepage Functions Advanced Mode Logging File for system log Advanced Mode Picture SettingsAdvanced Mode Encoder Profile Maximum bit rate Profile nameTarget bit rate Video resolution Expert SettingsDefault Encoding intervalMP SD Advanced Mode Encoder Streams264 BP+ bit-rate-limited Property Jpeg streamMax. frame rate Picture qualityAdvanced Mode Storage Management Device managerActivating and configuring storage media Recording mediaISCSI Media Local MediaFormatting storage media Deactivating storage mediaAdvanced Mode Recording Profiles Stream profile settingsSettings for selected streams Pre-alarm timePost-alarm time Alarm streamAdvanced Mode Retention Time Alarm input / Motion/Audio alarm / Video loss alarmVirtual alarm Export to FTPAdvanced Mode Recording Scheduler Holidays Deleting holidaysTime periods Activating the recordingCannot change any of these settings Advanced Mode Recording StatusAdvanced Mode Alarm Connections Connect on alarm Destination passwordNumber of destination IP address Destination IP addressRemote port Video outputDecoder SSL encryptionAdvanced Mode VCA Advanced Mode VCA profiles VCA configuration Alarm statusAggregation time s Analysis typeMotion detector MOTION+ only Sensitivity MOTION+ onlyMinimum object size MOTION+ only Debounce time 1 s MOTION+ onlyAdvanced Mode VCA Scheduled Scene too noisyHolidays Advanced Mode VCA Event triggered TriggerAdvanced Mode Alarm E-Mail Format Standard with JpegAttach Jpeg from camera Destination addressAdvanced Mode Alarm Task Editor Advanced Mode Alarm Inputs Advanced Mode RelayYou can configure the alarm inputs of the VOT-320 Alarm inputOperating mode Video alarmMotion alarm Idle stateAdvanced Mode COM1 Advanced Mode Network Http browser port Automatic IP assignmentDNS server address Interface mode ETH Enable DynDNSHttps browser port RCP+ portEnter the password you registered at DynDNS.org here User nameEnter the user name you registered at DynDNS.org here Force registration nowAdvanced Mode Advanced SnmpAuthentication Snmp host address / 2. Snmp host addressSnmp traps IdentityMulticast Address Advanced Mode MulticastEnable Advanced Mode FTP Posting Advanced Mode Encryption Advanced Mode MaintenanceDownload ConfigurationUpload SSL certificate Advanced Mode LicensesMaintenance log Advanced Mode System Overview Function test Operation Operation with Microsoft Internet ExplorerVOT-320 Operation en Display stamping 2The LivepageImage selection View Control System Log / Event Log Digital I/OTriggering relay Image resolution Saving snapshotsRecording video sequences Running recording programExporting recordings RecordingsSelecting recordings Slide controls Controlling a playbackButtons Bookmarks ConnectingHardware connections between video servers Closing the connection with a terminal program Connecting on alarmConnecting with a terminal program 8Operation using software decoders Camera reset Maintenance and upgradesTesting the network connection 3Fuse replacement RepairsTransfer and disposal Export limitationsGeneral malfunctions 1Troubleshooting8Appendix Connect LED Firmware upload failed Repeat firmware upload Flashes redMalfunctions with iSCSI connections 4LEDsConnect opening a Link and ACT opening B7Serial interface 5Processor loadNetwork connection Power supply upper 2-pin terminal block Terminal blocksWindow defroster lower 2-pin terminal block PT control upper and lower 5-pin terminal blocksPin No Contact RS-232 mode RS-422 mode RS-485 mode Serial interface upper 6-pin terminal blockConfiguring the terminal Command inputsCommunication with terminal program Data terminalReboot Assigning an IP addressCopyrights Detector SpecificationsCamera 3Protocols/standards NtscGlossary Gbic GOPHttp IcmpLAN LUNMAC MIBRTP RtspSFP SniaWAN See Wide Area NetworkWfov Wide Field Of View, see FOVIndex EpromRadius VOT-320 Index en En Index Page Bosch Sicherheitssysteme GmbH