Proper password protection is only guaranteed when all higher authorization levels are also protected with a password. If a live password is assigned, for example, a service and a user password must also be set. When assigning passwords, you should therefore always start from the highest authorization level, service, and use different passwords.

Confirm password

In each case, enter the new password a second time to eliminate typing mistakes.

5.4

Basic Mode: Date/Time

Device date / Device time / Device time zone

If there are multiple devices operating in your system or network, it is important to synchronize their internal clocks. For example, it is only possible to identify and correctly evaluate simultaneous recordings when all units are operating on the same time. If necessary, you can synchronize the camera with your computer's system settings.

Click the Sync to PC button to copy your computer's system time to the VOT-320.

Time server IP address

The VOT-320 can receive the time signal from a time server using various time server protocols, and then use it to set the internal clock. The camera polls the time signal automatically once every minute.

Enter the IP address of a time server here.

Time server type

Select the protocol that is supported by the selected time server. Preferably, you should select SNTP server as the protocol. This supports a high level of accuracy and is required for special applications and subsequent function extensions.

Select Time server for a time server that works with the protocol RFC 868.

Bosch Sicherheitssysteme GmbH

Installation and Operating Manual

DOC V4.5 2010.09

Image 29
Contents VOT-320 Page Table of Contents Appendix Maintenance and upgradesOperation Glossary 106 Index 111 Specifications 104Camera 104 Detector Protocols/standards 105 About this manual PrefaceConventions in this manual Intended useRating plate EU DirectivesElectric shock hazard Safety informationInstallation and operation 3Maintenance and repair Parts included Product descriptionSystem requirements Additional configuration requirementsGeneral requirements Additional operational requirementsOverview of functions Tamper detection and video content analysis Remote controlBackup SnapshotsHttps SummaryControls and displays on the camera module Connections on the camera module 2Mounting 4Installation1Preparations En Installation Network 3ConnectionsPin EIA/TIA-568-A EIA/TIA-568-B Data interfaceRelay outputs Alarm inputsPan/tilt connection SD slot 4Power on/power offPower supply Final assembly Adjusting the lens only Wfov lenses7Setup using Bosch Video Client Installing the programAdditional parameters 1Connecting Configuration using a Web browserInstalling Mpeg ActiveX System requirementsMaximum number of connections Establishing the connectionProtected network Configuration menuProtected camera Making changes Starting configurationNavigation Camera name Basic Mode Device AccessPassword Confirm password Basic Mode Date/TimeDevice date / Device time / Device time zone Time server IP addressIP address Basic Mode NetworkSubnet mask Gateway addressBasic Mode Encoder Basic Mode System Overview Basic Mode RecordingInitiator extension Advanced Mode IdentificationCamera ID Advanced Mode Password Date format Advanced Mode Date/TimeDevice date / Device time Device time zoneTime stamping Advanced Mode Display StampingCamera name stamping Advanced Mode Appearance Advanced Mode Livepage Functions Advanced Mode Logging File for system log Advanced Mode Picture SettingsAdvanced Mode Encoder Profile Maximum bit rate Profile nameTarget bit rate Expert Settings Video resolutionDefault Encoding intervalMP SD Advanced Mode Encoder Streams264 BP+ bit-rate-limited Jpeg stream PropertyMax. frame rate Picture qualityDevice manager Advanced Mode Storage ManagementRecording media Activating and configuring storage mediaISCSI Media Local MediaDeactivating storage media Formatting storage mediaStream profile settings Advanced Mode Recording ProfilesPre-alarm time Settings for selected streamsPost-alarm time Alarm streamAlarm input / Motion/Audio alarm / Video loss alarm Advanced Mode Retention TimeVirtual alarm Export to FTPAdvanced Mode Recording Scheduler Deleting holidays HolidaysTime periods Activating the recordingCannot change any of these settings Advanced Mode Recording StatusAdvanced Mode Alarm Connections Destination password Connect on alarmNumber of destination IP address Destination IP addressVideo output Remote portDecoder SSL encryptionAdvanced Mode VCA Advanced Mode VCA profiles Alarm status VCA configurationAggregation time s Analysis typeSensitivity MOTION+ only Motion detector MOTION+ onlyMinimum object size MOTION+ only Debounce time 1 s MOTION+ onlyScene too noisy Advanced Mode VCA ScheduledHolidays Trigger Advanced Mode VCA Event triggeredAdvanced Mode Alarm E-Mail Standard with Jpeg FormatAttach Jpeg from camera Destination addressAdvanced Mode Alarm Task Editor Advanced Mode Relay Advanced Mode Alarm InputsYou can configure the alarm inputs of the VOT-320 Alarm inputVideo alarm Operating modeMotion alarm Idle stateAdvanced Mode COM1 Advanced Mode Network Http browser port Automatic IP assignmentDNS server address Enable DynDNS Interface mode ETHHttps browser port RCP+ portUser name Enter the password you registered at DynDNS.org hereEnter the user name you registered at DynDNS.org here Force registration nowSnmp Advanced Mode AdvancedSnmp host address / 2. Snmp host address AuthenticationSnmp traps IdentityMulticast Address Advanced Mode MulticastEnable Advanced Mode FTP Posting Advanced Mode Maintenance Advanced Mode EncryptionDownload ConfigurationUpload SSL certificate Advanced Mode LicensesMaintenance log Advanced Mode System Overview Function test Operation with Microsoft Internet Explorer OperationVOT-320 Operation en Display stamping 2The LivepageImage selection View Control System Log / Event Log Digital I/OTriggering relay Saving snapshots Image resolutionRecording video sequences Running recording programExporting recordings RecordingsSelecting recordings Slide controls Controlling a playbackButtons Bookmarks ConnectingHardware connections between video servers Closing the connection with a terminal program Connecting on alarmConnecting with a terminal program 8Operation using software decoders Camera reset Maintenance and upgradesTesting the network connection Repairs 3Fuse replacementTransfer and disposal Export limitationsGeneral malfunctions 1Troubleshooting8Appendix Firmware upload failed Repeat firmware upload Flashes red Connect LED4LEDs Malfunctions with iSCSI connectionsConnect opening a Link and ACT opening B7Serial interface 5Processor loadNetwork connection Terminal blocks Power supply upper 2-pin terminal blockWindow defroster lower 2-pin terminal block PT control upper and lower 5-pin terminal blocksSerial interface upper 6-pin terminal block Pin No Contact RS-232 mode RS-422 mode RS-485 modeCommand inputs Configuring the terminalCommunication with terminal program Data terminalAssigning an IP address RebootCopyrights Detector SpecificationsCamera Ntsc 3Protocols/standardsGlossary GOP GbicHttp IcmpLUN LANMAC MIBRtsp RTPSFP SniaSee Wide Area Network WANWfov Wide Field Of View, see FOVEprom IndexRadius VOT-320 Index en En Index Page Bosch Sicherheitssysteme GmbH