8.8 | Terminal blocks |
The
–
–
–
Power supply (upper 2-pin terminal block)
Connect the power supply to the upper
Window defroster (lower 2-pin terminal block)
The window defroster by default is connected to the lower
PT control (upper and lower 5-pin terminal blocks)
Pan/tilts are connected to the
Row | Pin No. | Contact | Function |
|
|
|
|
U | 1 | Pan Right | Panning to the right |
|
|
|
|
U | 2 | Pan Left | Panning to the left |
|
|
|
|
U | 3 | P/T Common | Return path for P/T motors |
|
|
|
|
U | 4 | Pan Position | Analog feedback on position |
|
|
|
|
U | 5 | Tilt Position | Analog feedback on position |
|
|
|
|
L | 1 | Tilt Up | Tilting up |
|
|
|
|
L | 2 | Tilt Down | Tilting down |
|
|
|
|
L | 3 | P/T Common | Return path for P/T motors |
|
|
|
|
L | 4 | PP Return | Supply for analog feedback of position |
|
|
|
|
L | 5 | PP Supply (+) | Supply for analog feedback of position |
|
|
|
|
Bosch LTC 9418/11 and LTC 9418/21 are recommended as pan/tilts. For additional information and wiring diagrams refer to the corresponding manuals.
CAUTION!
Please take note of the appropriate documentation when installing and operating the unit to be controlled.
The documentation contains important safety instructions and information about permitted uses.
Bosch Sicherheitssysteme GmbH | Installation and Operating Manual | DOC V4.5 2010.09 |