Bosch Appliances VOT-320 manual Profile name, Target bit rate, Maximum bit rate

Page 41

VOT-320

Configuration using a Web browser en 41

 

 

Pre-programmed profiles are available, each giving priority to different perspectives. Below is a brief description of the factory default settings for the encoder profiles.

High quality 1

For high bandwidth connections with IBBP GOP structure

High quality 2

For high bandwidth connections with IP GOP structure

Low bandwidth

For low bandwidth connections with lP GOP structure

DSL

For DSL connections with 500 kbps

ISDN (2B)

For ISDN connections via two B-channels

ISDN (1B)

For ISDN connections via one B-channel

MODEM

For analog modem connections with 20 kbps

GSM

For GSM connections at 9,600 baud

CAUTION!

Change the profiles only once you are fully familiar with all the configuration options. In the default setting, Stream 1 is transmitted for alarm connections and automatic connections. Bear this fact in mind when assigning the profile.

NOTICE!

All parameters combine to make up a profile and are dependent on one another. If you enter a setting that is outside the permitted range for a particular parameter, the nearest permitted value will be substituted when the settings are saved.

Profile name

You can enter a new name for the profile. The name is then displayed in the Non-recording profile list field on the Encoder Streams page in the lists of selectable profiles.

CAUTION!

Do not use any special characters, for example &, in the name.

Special characters are not supported by the system's internal management.

Target bit rate

You can limit the bit rate for the VOT-320 to optimize utilization of the bandwidth in your network. The target bit rate should be set according to the desired picture quality for typical scenes with no excessive motion.

For complex images or frequent changes of image content due to frequent movements, this limit can be temporarily exceeded up to the value entered in the Maximum bit rate field.

Maximum bit rate

This maximum bit rate is not exceeded under any circumstances. Depending on the video quality settings for the I and P-frames, this fact can result in individual images being skipped. The value entered here must be at least 10% higher than the value entered in the Target bit rate field. If the value entered here is too low, it will automatically be adjusted.

Bosch Sicherheitssysteme GmbH

Installation and Operating Manual

DOC V4.5 2010.09

Image 41
Contents VOT-320 Page Table of Contents Appendix Maintenance and upgradesOperation Glossary 106 Index 111 Specifications 104Camera 104 Detector Protocols/standards 105 About this manual PrefaceConventions in this manual Intended useRating plate EU DirectivesElectric shock hazard Safety informationInstallation and operation 3Maintenance and repair Parts included Product descriptionSystem requirements Additional configuration requirementsGeneral requirements Additional operational requirementsOverview of functions Tamper detection and video content analysis Remote controlBackup SnapshotsHttps SummaryControls and displays on the camera module Connections on the camera module 2Mounting 4Installation1Preparations En Installation Network 3ConnectionsPin EIA/TIA-568-A EIA/TIA-568-B Data interfaceRelay outputs Alarm inputsPan/tilt connection SD slot 4Power on/power offPower supply Final assembly Adjusting the lens only Wfov lenses7Setup using Bosch Video Client Installing the programAdditional parameters 1Connecting Configuration using a Web browserInstalling Mpeg ActiveX System requirementsMaximum number of connections Establishing the connectionProtected network Configuration menuProtected camera Making changes Starting configurationNavigation Camera name Basic Mode Device AccessPassword Confirm password Basic Mode Date/TimeDevice date / Device time / Device time zone Time server IP addressIP address Basic Mode NetworkSubnet mask Gateway addressBasic Mode Encoder Basic Mode System Overview Basic Mode RecordingInitiator extension Advanced Mode IdentificationCamera ID Advanced Mode Password Date format Advanced Mode Date/TimeDevice date / Device time Device time zoneTime stamping Advanced Mode Display StampingCamera name stamping Advanced Mode Appearance Advanced Mode Livepage Functions Advanced Mode Logging File for system log Advanced Mode Picture SettingsAdvanced Mode Encoder Profile Maximum bit rate Profile nameTarget bit rate Expert Settings Video resolutionDefault Encoding intervalMP SD Advanced Mode Encoder Streams264 BP+ bit-rate-limited Jpeg stream PropertyMax. frame rate Picture qualityDevice manager Advanced Mode Storage ManagementRecording media Activating and configuring storage mediaISCSI Media Local MediaDeactivating storage media Formatting storage mediaStream profile settings Advanced Mode Recording ProfilesPre-alarm time Settings for selected streamsPost-alarm time Alarm streamAlarm input / Motion/Audio alarm / Video loss alarm Advanced Mode Retention TimeVirtual alarm Export to FTPAdvanced Mode Recording Scheduler Deleting holidays HolidaysTime periods Activating the recordingCannot change any of these settings Advanced Mode Recording StatusAdvanced Mode Alarm Connections Destination password Connect on alarmNumber of destination IP address Destination IP addressVideo output Remote portDecoder SSL encryptionAdvanced Mode VCA Advanced Mode VCA profiles Alarm status VCA configurationAggregation time s Analysis typeSensitivity MOTION+ only Motion detector MOTION+ onlyMinimum object size MOTION+ only Debounce time 1 s MOTION+ onlyScene too noisy Advanced Mode VCA ScheduledHolidays Trigger Advanced Mode VCA Event triggeredAdvanced Mode Alarm E-Mail Standard with Jpeg FormatAttach Jpeg from camera Destination addressAdvanced Mode Alarm Task Editor Advanced Mode Relay Advanced Mode Alarm InputsYou can configure the alarm inputs of the VOT-320 Alarm inputVideo alarm Operating modeMotion alarm Idle stateAdvanced Mode COM1 Advanced Mode Network Http browser port Automatic IP assignmentDNS server address Enable DynDNS Interface mode ETHHttps browser port RCP+ portUser name Enter the password you registered at DynDNS.org hereEnter the user name you registered at DynDNS.org here Force registration nowSnmp Advanced Mode AdvancedSnmp host address / 2. Snmp host address AuthenticationSnmp traps IdentityMulticast Address Advanced Mode MulticastEnable Advanced Mode FTP Posting Advanced Mode Maintenance Advanced Mode EncryptionDownload ConfigurationUpload SSL certificate Advanced Mode LicensesMaintenance log Advanced Mode System Overview Function test Operation with Microsoft Internet Explorer OperationVOT-320 Operation en Display stamping 2The LivepageImage selection View Control System Log / Event Log Digital I/OTriggering relay Saving snapshots Image resolutionRecording video sequences Running recording programExporting recordings RecordingsSelecting recordings Slide controls Controlling a playbackButtons Bookmarks ConnectingHardware connections between video servers Closing the connection with a terminal program Connecting on alarmConnecting with a terminal program 8Operation using software decoders Camera reset Maintenance and upgradesTesting the network connection Repairs 3Fuse replacementTransfer and disposal Export limitationsGeneral malfunctions 1Troubleshooting8Appendix Firmware upload failed Repeat firmware upload Flashes red Connect LED4LEDs Malfunctions with iSCSI connectionsConnect opening a Link and ACT opening B7Serial interface 5Processor loadNetwork connection Terminal blocks Power supply upper 2-pin terminal blockWindow defroster lower 2-pin terminal block PT control upper and lower 5-pin terminal blocksSerial interface upper 6-pin terminal block Pin No Contact RS-232 mode RS-422 mode RS-485 modeCommand inputs Configuring the terminalCommunication with terminal program Data terminalAssigning an IP address RebootCopyrights Detector SpecificationsCamera Ntsc 3Protocols/standardsGlossary GOP GbicHttp IcmpLUN LANMAC MIBRtsp RTPSFP SniaSee Wide Area Network WANWfov Wide Field Of View, see FOVEprom IndexRadius VOT-320 Index en En Index Page Bosch Sicherheitssysteme GmbH