Bosch Appliances VOT-320 manual Summary, Https

Page 14

14 en Product description

VOT-320

 

 

Summary

The thermal IP camera VOT-320 provides the following main functions:

Outstanding image quality with 320 × 240 VOx sensor

Video and data transmission over IP data networks

Tri-streaming function for the encoder for simultaneous encoding with three individually definable profiles

Multicast function for simultaneous image transmission to multiple receivers

One analog BNC composite video output for set-up procedure (NTSC)

Video encoding to international standard H.264

Integrated Ethernet port (10/100 Base-T)

SD slot for SD cards for local storage

Transparent, bidirectional data channel via RS-232/RS-422/RS-485 serial interface

Outputs for direct control of Bosch pan/tilts

Configuration and remote control of all internal functions via TCP/IP, also secured via

HTTPS

Pre-installed IVA video content analysis algorithm

Password protection to prevent unauthorized connection or configuration changes

Extensive, flexible storage options

Two alarm inputs and two relay outputs

Built-in video sensor for motion and tamper alarms

Event-controlled automatic connection

Convenient maintenance via uploads

Flexible encryption of control and data channels

Authentication according to international standard 802.1x

TEC-less operation without thermo-electric cooler

Automatic flat-field correction (FFC)

DOC V4.5 2010.09

Installation and Operating Manual

Bosch Sicherheitssysteme GmbH

Image 14
Contents VOT-320 Page Table of Contents Appendix Maintenance and upgradesOperation Glossary 106 Index 111 Specifications 104Camera 104 Detector Protocols/standards 105 Conventions in this manual PrefaceAbout this manual Intended useEU Directives Rating plateElectric shock hazard Safety informationInstallation and operation 3Maintenance and repair Product description Parts includedGeneral requirements Additional configuration requirementsSystem requirements Additional operational requirementsOverview of functions Backup Remote controlTamper detection and video content analysis SnapshotsSummary HttpsControls and displays on the camera module Connections on the camera module 2Mounting 4Installation1Preparations En Installation Pin EIA/TIA-568-A EIA/TIA-568-B 3ConnectionsNetwork Data interfaceRelay outputs Alarm inputsPan/tilt connection SD slot 4Power on/power offPower supply 7Setup using Bosch Video Client Adjusting the lens only Wfov lensesFinal assembly Installing the programAdditional parameters Installing Mpeg ActiveX Configuration using a Web browser1Connecting System requirementsEstablishing the connection Maximum number of connectionsProtected network Configuration menuProtected camera Making changes Starting configurationNavigation Camera name Basic Mode Device AccessPassword Device date / Device time / Device time zone Basic Mode Date/TimeConfirm password Time server IP addressSubnet mask Basic Mode NetworkIP address Gateway addressBasic Mode Encoder Basic Mode Recording Basic Mode System OverviewInitiator extension Advanced Mode IdentificationCamera ID Advanced Mode Password Device date / Device time Advanced Mode Date/TimeDate format Device time zoneTime stamping Advanced Mode Display StampingCamera name stamping Advanced Mode Appearance Advanced Mode Livepage Functions Advanced Mode Logging File for system log Advanced Mode Picture SettingsAdvanced Mode Encoder Profile Maximum bit rate Profile nameTarget bit rate Default Video resolutionExpert Settings Encoding intervalMP SD Advanced Mode Encoder Streams264 BP+ bit-rate-limited Max. frame rate PropertyJpeg stream Picture qualityAdvanced Mode Storage Management Device managerISCSI Media Activating and configuring storage mediaRecording media Local MediaFormatting storage media Deactivating storage mediaAdvanced Mode Recording Profiles Stream profile settingsPost-alarm time Settings for selected streamsPre-alarm time Alarm streamVirtual alarm Advanced Mode Retention TimeAlarm input / Motion/Audio alarm / Video loss alarm Export to FTPAdvanced Mode Recording Scheduler Time periods HolidaysDeleting holidays Activating the recordingCannot change any of these settings Advanced Mode Recording StatusAdvanced Mode Alarm Connections Number of destination IP address Connect on alarmDestination password Destination IP addressDecoder Remote portVideo output SSL encryptionAdvanced Mode VCA Advanced Mode VCA profiles Aggregation time s VCA configurationAlarm status Analysis typeMinimum object size MOTION+ only Motion detector MOTION+ onlySensitivity MOTION+ only Debounce time 1 s MOTION+ onlyAdvanced Mode VCA Scheduled Scene too noisyHolidays Advanced Mode VCA Event triggered TriggerAdvanced Mode Alarm E-Mail Attach Jpeg from camera FormatStandard with Jpeg Destination addressAdvanced Mode Alarm Task Editor You can configure the alarm inputs of the VOT-320 Advanced Mode Alarm InputsAdvanced Mode Relay Alarm inputMotion alarm Operating modeVideo alarm Idle stateAdvanced Mode COM1 Advanced Mode Network Http browser port Automatic IP assignmentDNS server address Https browser port Interface mode ETHEnable DynDNS RCP+ portEnter the user name you registered at DynDNS.org here Enter the password you registered at DynDNS.org hereUser name Force registration nowAdvanced Mode Advanced SnmpSnmp traps AuthenticationSnmp host address / 2. Snmp host address IdentityMulticast Address Advanced Mode MulticastEnable Advanced Mode FTP Posting Advanced Mode Encryption Advanced Mode MaintenanceDownload ConfigurationUpload SSL certificate Advanced Mode LicensesMaintenance log Advanced Mode System Overview Function test Operation Operation with Microsoft Internet ExplorerVOT-320 Operation en Display stamping 2The LivepageImage selection View Control System Log / Event Log Digital I/OTriggering relay Recording video sequences Image resolutionSaving snapshots Running recording programExporting recordings RecordingsSelecting recordings Slide controls Controlling a playbackButtons Bookmarks ConnectingHardware connections between video servers Closing the connection with a terminal program Connecting on alarmConnecting with a terminal program 8Operation using software decoders Camera reset Maintenance and upgradesTesting the network connection Transfer and disposal 3Fuse replacementRepairs Export limitationsGeneral malfunctions 1Troubleshooting8Appendix Connect LED Firmware upload failed Repeat firmware upload Flashes redConnect opening a Malfunctions with iSCSI connections4LEDs Link and ACT opening B7Serial interface 5Processor loadNetwork connection Window defroster lower 2-pin terminal block Power supply upper 2-pin terminal blockTerminal blocks PT control upper and lower 5-pin terminal blocksPin No Contact RS-232 mode RS-422 mode RS-485 mode Serial interface upper 6-pin terminal blockCommunication with terminal program Configuring the terminalCommand inputs Data terminalReboot Assigning an IP addressCopyrights Detector SpecificationsCamera 3Protocols/standards NtscGlossary Http GbicGOP IcmpMAC LANLUN MIBSFP RTPRtsp SniaWfov WANSee Wide Area Network Wide Field Of View, see FOVIndex EpromRadius VOT-320 Index en En Index Page Bosch Sicherheitssysteme GmbH