Attachment A: External Alarm
In addition to the motion detection executed by the internal software application, the product can connect to external infrared detectors, beepers, and smoke detectors. For more information about these external devices, contact to your local retailer, dealer or installation service provider. This product provides a standard Alarm I/O for you.
This product is provided with 2 sets of digital inputs and 1 set of digital outputs. Pin 1 and Pin 2 of the terminal are used for external sensor 1, while Pin 2 and Pin 3 are used for external sensors 2. Please DO NOT connect with any device providing power for these three Pins to avoid burning. Pin 4, 5, and 6 are relays to control the normal open/normal close of external devices. These three Pins are relay output contains no power output.
Pin | Function |
|
|
1 | Alarm Input #1 (A) Dry Contact |
|
|
2 | Alarm Input #1/2 (K) Dry Contact |
|
|
3 | Alarm Input #2 (A) Dry Contact |
|
|
4 | Alarm Output #1 (NC) Dry Contact |
|
|
5 | Alarm Output #1 (COM) Dry Contact |
|
|
6 | Alarm Output #1 (NO) Dry Contact |
|
|
68