8 Object directory

Value description

 

 

Subindex

00h, number of elements

 

 

Meaning

Number of subindexes

 

Access

read-only

 

PDO mapping

 

Value range

 

Default value

4

 

Can be saved

 

 

 

 

 

 

 

Subindex

01h, 1st mapped object T_PDO4

 

Meaning

First object for the mapping in T_PDO4

 

Access

read-only

 

PDO mapping

 

Value range

 

Default value

0x301E0410

 

Can be saved

 

 

 

 

 

 

 

Subindex

02h, 2nd mapped object T_PDO4

 

Meaning

Second object for the mapping in T_PDO4

 

Access

read-only

 

PDO mapping

 

Value range

 

Default value

0x301E0308

 

Can be saved

 

 

 

0198441113586, V2.01, 11.2008

Fieldbus interface

91

Image 91
Contents IL1F CANopen DS301 Important information Table of Contents Table of Contents IL1F CANopen DS301 Object directory Table of Contents IL1F CANopen DS301 Writing conventions and symbols Writing conventions and symbols IL1F CANopen DS301 About this manual IntroductionCAN-Bus Fieldbus devices networked via can bus Operating modes and functions in fieldbus modeCan users and manufacturers organization Documentation and literature referencesIntroduction IL1F CANopen DS301 Before you begin safety information Before you begin safety information IL1F CANopen DS301 Communication layers BasicsCANopen technology CANopen description languageIndex hex Object groups Supported By the drive ObjectsIL1F CANopen DS301 Basics CANopen reference model CANopen profilesObject dictionary Communication profileIndex Subindex Object Meaning Index range Object groups Supported Hex By the drive Communication objects Communication objectsCOB ID with function code and node address TPDO4 Master slave relationships Communication relationshipsClient-server relationship Overview Service data communicationSDO data exchange 11 SDO message, example SDO messageMessage type Data length used Bytes Reading and writing dataMessage type Data length used Byte Bytes 14 Reading a parameter value15 Response with error message error response Process data communication 16 PDO data exchange PDO data exchangeUINT32 18 Requesting a message with RTR = Dynamic and static PDO mappingStructure of RPDO4 Receive PDO RPDO4 master slaveState machine drivectrl JOG Operating modes modeCtrlTransmit PDO TPDO4 product to master @ Warning20 Structure of TPDO4 Structure of TPDO4Bit Name Description Handshake with Mode Toggle BitMaster Slave Xend 22 Mode Toggle Handshake, short movementBasics IL1F CANopen DS301 23 Error message with the Emcy object Emergency service25 Sync message Synchronization27 Cyclic and acyclic transmission NMT services for device control Network management servicesInitialization NMT service Transition MeaningPersistent data memory Command Specifier NMT service Transition NMT services for connection monitoringNode/Life guarding 31 Acknowledgement of the NMT slave 32 Node Guarding and Life Guarding with time intervals Installation Installation IL1F CANopen DS301 Commissioning the device CommissioningAddress and baud rate Starting fieldbus modeCommissioning the fieldbus network Error Error class Cause of error Troubleshooting TroubleshootingCreating a new network SyCon CANopen configuration softwareSelecting the CANopen master Setting the bus parameters Selecting and inserting nodes Overview OperationOperation IL1F CANopen DS301 Receive data Using SDO commandsWriting parameters Transmit dataReading a parameter Synchronous errorsIndex Sub Data Description Changing operating states with PDO4 Operating Name Power Description State StageBit no Value Meaning Triggering a Quick Stop Switching the power stage on and offExample Come to a standstill System is to resume opera Resetting faults Examples for the operating modes with PDO4 Operating mode Profile Position absolute positioning Operating mode Profile Velocity Operating mode Profile Position relative positioningMaster --- Slave Position settingOperating mode Homing Asynchronous errors Error signaling via PDO4Positioning running xerr=0 Operation IL1F CANopen DS301 Fieldbus communication error diagnostics Diagnostics and troubleshootingMessage objects Error diagnostics via fieldbusMessages on the device status Bit Message Meaning CANopen error messagesError register Error code tableError code Meaning SDO error message AbortData type Value range Data length Specifications for the objectsObject directory Object code Meaning CodingObjects, overview Index Subindex Designation Obj. code Data type AccessObjects of the product Error registerDevice type 100Ch Bit coding, subindex 00h1008h Manufacturer device nameIndex 100D h Object name Life time factor Object code Index 1018 h Object name Identity Object Object code Data type PDO Communication parameter Bit Acces Value Meaning Bit assignment subindex 01hBit 30 RTR bit Bit coding, subindex 02h1603h Receive PDO4 mapping Value description BitMeaning 1803h Transmit PDO4 communication parameterSubindex 03 h, inhibit time TPDO4 Meaning IL1F CANopen DS301 Object directory PDO4 mapping 1603h Units and conversion tables GlossaryMoment of inertia TemperatureRotation TorqueTerms and Abbreviations Default value Factory settingPower amplifier See power stage Can IndexIndex IL1F CANopen DS301 IL1F CANopen DS301 Index NMT IL1F CANopen DS301 Index 102 Fieldbus interface