6.4TROUBLESHOOTING THE HEART RATE CHEST STRAP
HEART RATE READING IS ERRATIC OR ABSENT ENTIRELY
Malfunction | Probable Cause | Corrective Action |
Heart rate reading is erratic or | Chest strap transmitter electrodes | Wet the chest strap transmitter |
absent entirely | are not wet enough to pick up | electrodes (see section 3.2). |
| accurate heart rate readings. |
|
| Chest strap transmitter electrodes | Ensure the chest strap transmitter |
| are not laying flat against the skin. | electrodes are laying flat against |
|
| the skin (see section 3.2). |
|
|
|
| Chest strap transmitter needs | Wash the chest strap transmitter |
| cleaning. | with mild soap and water. |
|
|
|
| Chest strap transmitter is not with- | Make sure the chest strap trans- |
| in 3 feet (one meter) of the heart | mitter is within three feet (one |
| rate receiver. | meter) of the heart rate receiver. |
| Chest strap battery is depleted. | Contact Life Fitness Customer |
|
| Support Services* for instructions |
|
| on how to have the chest strap |
|
| replaced. |
Abnormally elevated heart rate | Electromagnetic interference from | Move the treadmill a few inches |
readings | television sets and/or antennas. | away from the probable cause, or |
|
| move the probable cause a few |
| Electromagnetic interference from | |
| inches away from the treadmill, | |
| cell phones. | |
| until the heart rate readings are | |
|
| |
| Electromagnetic interference from | |
| accurate. | |
| CD players. |
|
|
|
|
| Electromagnetic interference from |
|
| computers. |
|
|
|
|
| Electromagnetic interference from |
|
| cars. |
|
| Electromagnetic interference from |
|
| high voltage power lines. |
|
|
|
|
| Electromagnetic interference from |
|
| motor driven exercise equipment. |
|
| Electromagnetic interference from |
|
| another heart rate transmitter with- |
|
| in three feet (one meter). |
|
|
|
|
* See Section 6.6 “How to Obtain Product Service” for contact information.