ResMed S9 VPAP Tx manual S9 Vpap Tx basics, Key Function

Page 10

S9 VPAP Tx basics

Info menu button

LCD screen

Start/Stop button

Setup menu button

Alarm mute

Alarm and

 

button

therapy LEDs

Push dial

 

 

 

 

Key

Function

 

 

Start/Stop button

Starts or stops treatment.

 

 

 

 

Power Save mode—hold for three seconds.

 

 

 

 

 

Info menu button

Allows you to view the device service information or to exit from

 

 

the menu.

 

 

 

 

 

Setup menu button

Allows you to make changes to settings or to exit from the menu.

 

 

 

 

 

Turning the dial allows you to scroll through the menu and change

 

 

Push dial

settings. Pushing the dial allows you to enter into a menu and

 

 

 

confirm your choice.

 

 

 

Press once to mute alarms. Press a second time to un-mute. If

 

 

Alarm mute button

the problem is still present, the alarm will sound again after two

 

 

 

minutes.

 

 

 

Displays the menus, treatment screens and reminders.

 

 

LCD screen

Backlight—when treatment is being delivered, the backlight

 

 

(including the Start/Stop button) automatically turns off after

 

 

 

 

 

 

30 seconds, otherwise it turns off after 3 minutes.

 

 

Alarm LED

Yellow LED—flashes during an alarm.

 

 

 

 

 

 

Therapy LED

Blue LED—always on during therapy (if enabled in the Options

 

 

menu).

 

 

 

 

 

 

 

6

Image 10
Contents S9 Vpap Tx Page S9 Vpap Tx Contents General warnings and cautions S9 Vpap Tx contraindications WelcomeS9 Vpap Tx indications for use S9 Vpap Tx adverse effectsS9 Vpap Tx at a glance Antibacterial filters MasksSupplemental oxygen HumidifierTherapy mode Description Therapy modesS9 Vpap Tx basics Key FunctionSetting up the S9 Vpap Tx Filling the water tub English Mask type Settings Mask and air tubing settingsAir tubing Specifications Settings About the menus Navigating the menusHome menu Climate Control Changing settings via the Home menuHumidity level Mask FitViewing the treatment screens Treatment screen parameters Parameter Modes DescriptionSettings Setup menuSetup menu access ConfigurationRange Description Clinical setup menu parametersParameter Modes Ü ü ü ü ü ü ü üParameter Modes Range Description Ü ü üLED Info menu ServiceParameter Description Mode TemperatureManaging Climate Control Heated tubeDelivering therapy Adding supplemental oxygen To add supplemental oxygenCleaning and maintenance Filter EfficiencyAlarms menu Working with alarmsTesting the alarms No display TroubleshootingProblem/Possible cause Solution Insufficient air delivered from the deviceLeaking water tub Alarm is activated and the LCD screen display disappearsWater splashing on your face from the H5i Air feels too warm/cold in the maskGeneral technical specifications Technical specificationsS9 Vpap Tx technical specifications Pneumatic flow path Displayed values Value Range Display resolutionFlow maximum at set pressures MinSymbols ServicingLimited warranty ProductPage GLO Multi