Installation - venting
Table II
Maximum effective  | Internal duct di-  | 
duct length allowable  | ameter required  | 
10 m with Ring adapter  | 100 mm  | 
20 m without Ring adapter  | 100 mm  | 
40 m without Ring adapter  | 125 mm  | 
100 m without Ring adapter  | 150 mm  | 
3. Calculation example
Installation to the rear, left or right hand side of the machine
At the rear
The dryer is delivered with this connec- tion open.
^Fit one of the venting systems de- scribed on the following pages.
Left or right side of the machine.
A  | Wall pipe, with louvred vent  | 
  | 
  | = 1 x 3.8 m Additional duct  | = 3.8 m  | 
  | length  | 
  | 
B/D  | 2 Elbows, 90°  | 
  | 
  | = 2 x 0.8 m Additional duct  | = 1.6 m  | 
  | length  | 
  | 
C  | 0.5 m plastic piping  | 
  | 
  | = 0.5 x 1 m Additional duct  | = 0.5 m  | 
  | length  | 
  | 
E  | Side connection, left  | 
  | 
  | = 1 m Additional duct length  | = 1.0 m  | 
  | Effective duct length  | = 6.9 m  | 
Result: A duct diameter of 100 mm is adequate as the effective duct length is less than the 20 m specified in Table II.
^Remove the left or right hand side cover cap. Do not remove the frame. Refit it in the rear outlet.
^Ensure it is securely in position so that it cannot fall out when the dryer is in operation.
^Fit one of the venting systems de- scribed on the following pages.