Venting system with plastic piping

Plastic piping is a good option where the vented air has to be ducted for some distance. The smooth walls of the pipe are less resistant to the vented air than the walls of a flexible vent hose, for example. Time and en- ergy consumption are better with plastic piping.

^The following items are required: . .

. . . an adapter* with rib on the inside.

. . . a wall vent kit* or window vent kit*.

* (Miele optional accessory)

. . . Suitable piping available from your dealer or builder’s merchant. Where the pipe diameter is more than 100 mm, additional adapters are nec- essary (e.g. to increase from C 100 to 125 mm) to connect the pipe to the dryer.

AThe ring adapter (1) only needs to be fitted into the Miele adapter (2), if the total duct length is less than 10 m.

If the total duct length is greater than 10 m the ring adapter is not required.

BFit Miele adapter (2) into the vent opening on the dryer.

CAttach the pipe (3).

Example

1.Wall vent kit

(Separate fitting instructions are supplied with the Miele wall vent kit).

2.Adapter

3.Plastic piping, diameter DN 100

33

Image 33
Contents Operating instructions for vented tumble dryer T Contents Consumption data Technical data Correct use Technical safetyOperation Page Using accessories Disposal of the packing material Caring for the environmentDisposal of your old appliance Energy saving tipsProgramme selector Control panelProgramme sequence and check lamps Start button Door buttonWash care labels Tips on dryingProgrammes Fabric type Special notes Low temperatureNormal+ NormalMinimum Iron Programme chartSmoothing Hand careWarm air Cool airHow to dry correctly Load the drum Switch on the dryerPrepare the laundry Start the programme Select a programmeAt the end of a programme To cancel a programmeSelecting a different programme Interrupting a programmeCleaning and care Cleaning the fluff filterTumble dryer Problem solving guide Fluff Problem Possible cause Remedy There is a build upLaundry is not suffi Ciently dryProblem Possible cause Remedy Drying process Even switches offGoes on too long or Programme again Tons or Minimum Iron programme. If the drum isTo change the interior drum lamp After sales service PC indicator lamp Interface for service techniciansRepairs Front view InstallationInstallation Transporting the machine to its installation siteAligning the machine Installation site Replacing the lidWasher-dryer stack Electrical connection Procedure Installation ventingGeneral AvoidCalculating the effective duct length To calculate the effective duct lengthInternal duct diameter Calculation example At the rear Left or right side of the machine Venting system with Flexible ducting hose Venting systems overviewInstallation examples venting sys- tem with flexible hose Example Venting system with plastic pipingConnecting directly to a wall vent Main venting duct Height of venting outlet for washer dryer stack Washer dryer stackCottons Consumption dataTechnical data Programmable functions for changing standard settings Programmable functions Is switched onIncreased drying level in the Cottons programmes To checkIncreased drying level in the Minimum Iron programmes Buzzer