Troubleshooting Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing requires power.
Stack Dryer Diagnostic Code
|
|
| Try to clear the |
|
d9 | diagnostic code by |
| ||
pressing the |
| |||
Voltage Problem |
|
| Delicates keypad |
|
|
| |||
Less Than 90 VAC | for more than 1 |
| ||
|
|
| second while the |
|
|
|
| code is displayed. |
|
|
|
|
|
|
Exit service mode , and pause for 10 seconds, enter service mode.
Did the
diagnostic code Yes cancel?
No
Low voltage was sensed on the power line, but is now ok.
| Check installation |
|
|
|
|
|
|
|
|
|
|
| |
| to insure proper |
|
|
|
|
|
|
|
|
|
| Check installation | |
| power going to this |
|
|
|
|
| Are other machines |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| to insure proper | |||
| dryer. If d9 |
|
| No |
| at this location giving a d9 |
| Yes |
|
| |||
|
|
|
|
|
|
| power going to all | ||||||
| persist, check the |
|
|
|
|
| diagnostic code? |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| of the dryers | |||
| wiring or replace |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| ||
| the transformer |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
If problem persists replace |
|
|
|
|
|
|
|
|
| ||||
| the control board. |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Clear diagnostic |
|
|
|
|
|
|
|
|
| |
|
|
| d12 indicates |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| code by pushing a |
|
|
|
|
|
|
|
|
| ||
d12 or d14 Motor |
|
| lower dryer motor |
|
|
|
|
| Does | |||||||
|
| Delicates keypad |
|
|
| |||||||||||
sense. d14 |
|
|
|
|
| diagnostic code |
|
|
| |||||||
Sensed Problem |
|
| for at least 1 |
|
|
|
|
|
| |||||||
indicates upper |
|
|
|
|
| remain? |
| |||||||||
|
|
|
|
| second while code |
|
|
|
| |||||||
|
|
| dryer motor sense |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| is displayed. |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Yes | |
|
|
|
|
|
|
|
|
| No |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
False indication
control board
Replace control
board
d16
PR Models Only
Is card reader
installed?
No
Check wiring between debit card reader and control board
Power down and
up machine to
reset card reader
Replace card
reader or
control board.
Install reader or use PDA to change mode out of
Gen 2 debit mode
36 | 16022904 Rev. 0 | ©2004 Maytag Appliances Company |