Maytag MLE/MLG23PDF manual Front Shroud Assembly Removal, Outlet Duct, Shroud & Tumbler Front

Page 41

Disassembly Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to unit before servicing.

Front Shroud Assembly Removal

1.Disconnect power supply to unit.

2.Remove Front Panel and Door Assembly.

3.Remove hold down brackets securing Top Cover to the Cabinet.

4.Remove four outer perimeter screws holding Shroud Assembly to cabinet.

NOTE: Remove the lowest outside screws on each corner and then the top outside screws. Leave the four inner screws in place.

Remove these four screws.

Screws

5.Pull Front shroud Assembly out and away from tumbler.

Note: Partially lift the Top Cover.

Note: When reinstalling the Front Shroud Assembly, lift the front inner edge of the tumbler to allow the front of the tumbler to rest on the teflon (Rulon™) bearings on the shroud and tumbler front assembly. Also, check the front felt seal to ensure it is outside the lip of the tumbler.

Outlet Duct, Shroud & Tumbler Front

1.Disconnect power supply to unit.

2.Remove the shroud and tumbler front assembly from the dryer.

3.Remove the two screws securing the shroud to the tumbler front and the two screws securing the shroud to the outlet duct. Pull the shroud free from the assembly.

Remove

Four

Screws

4.Remove the four 1/4" hex head screws and the one cross recess countersunk screw securing the outlet duct to the tumbler front.

Note: Two of the hex head screws are hidden under the felt seal. Pull the outlet duct free from the tumbler front.

Remove

Five Screws

4.When reattaching the outlet duct assembly to the tumbler front, install the center screw (found above the grid area) first, followed by the four outside screws in any order.

Install First

Screws

©2004 Maytag Appliances Company

16022904 Rev. 0

41

Image 41
Contents Commercial Single Stack Dryers Important Information Table of Contents Important Safety Information Proper Grounding and Polarization of 120 Volts Wall Outlets About Ground WiresGeneral Information Related Publications Explanation Grounding InstructionsParts and Accessories ServiceModel Identification Commercial Dryer NomenclatureAir movement measured in cubic feet per minute TERMINOLOGY/DEFINITIONS Term DefinitionsWater 1 o F HOW IT Works GAS Valve AssemblyRadiant Sensor Contact Closed Function of Gas Valve SystemPower Interruptions Safety FeaturesGas Conversions Ignition FailuresGeneral Information Exhaust Ducts General SpecificationsWattage Specifications Drive Motor Check Electrical TroubleshootingAir Shutter Adjustment Centrifugal SwitchMotor Test Cord Drive Motor TestManometers How to UseWill Not Shut-Off Mechanical Troubleshooting Will Not RunWill Not Dry Noisy and/Or VibrationSingle Dryer Troubleshooting Guide Cannot Enter Or Dryer Stopped with Zero Minutes Remaining DisplayExit OperatorDropped Into Machine Credited Are Eventually Lost Display Flashes User ModeKey Inputs Control Does NotRespond To Dryer Drum Will Not Turn To Coin 1 or ResponseWill not Respond to handheld Will Not Keep Time Of Day During Power InterruptionsNo Decimal Point Is UsedDryer Will Not HeatDryer Diagnostic Program Single Dryer Diagnostic ProgramDoor Sense Problem Single Dryer Diagnostic CodeVAC Display Is Blank Stack Dryer Troubleshooting GuideAbnormal Display Or Function Upper or Lower Dryer Has Zero Minutes Remaining DisplayBoard Does ControlNot KeypadsKeep Time Day Response To Coin Or CoinDuring InterruptionCannot Dryer Runs Without Program Selection Drum Will Not Turn Stack Dryer Diagnostic Program D1 or d17 Door Sense Problem Stack Dryer Diagnostic CodeVoltage Problem Control Panel Touch Pad AssemblyMicroprocessor Board TransformerCoin Vault Switch Service Door SwitchDoor Assembly Coin SensorFront Panel Reversing Door AssemblyDoor Disassembly Top Cover Door SwitchOutlet Duct, Shroud & Tumbler Front Front Shroud Assembly RemovalBearing & Pads Lint FilterFront Seal BeltBaffles Rear Shroud AssemblyInstalling Drive Belt Back Seal Roller and Bearing AssemblyThermostats Blower AssemblyCycling Thermostat Low-cycling ThermostatBlower Idler Arm Assembly Exhaust Duct Pipe Assembly BreakdownMotor Switch Drive Motor Assembly Igniter Gas Valve AssemblyCoils Combustion Cone Gas ValveInlet Duct Heater EnclosureStack Dryer Sloped Front Models Service Panel and SwitchAccess Cover Coin Drop MicroprocessorSwing Out Away Remove ScrewsStack DRYER-MN Models Stack Dryer Sloped Front PRTimer Push-To-Start SwitchSelector Switch Machine-In-Use LightStack DRYER-FLAT Front Models Front Shroud AssemblyMotor & Heater Relays Appendix a Pricing Programming ProceduresFixed Vend Pricing SET UP Codes Money Counter Option Steps 3. thru 9. codes are skipped if mode 2.00 is selected00 7.STARTING of Special Pricing Hour Value of Coin 2 Canadian Dollar Drop White & Colors keypad Example Dryer Help Mode Dryer Diagnostic ModeAll Single Load Models Stacked Models Only