Troubleshooting Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing requires power.
Stack Dryer Troubleshooting Guide
Will not
respond to
handheld
PDA
Does PDA
respond to other
machines?
No
Yes
Check optic
window for
obstructions, dirt,
or scratches.
PDA has failed.
If problem still exists replace control board
Control |
| When service door is | |||||
| |||||||
Board Does |
| ||||||
| closed, dryer door | ||||||
Not |
|
|
| must be closed for | |||
|
| ||||||
Respond To |
| corresponding | |||||
Keypads |
| keypads to work. | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Enter operator mode | |||
|
|
|
| ||||
|
|
|
| using service switch. | |||
|
|
|
| Does display contain | |||
|
|
|
| a diagnostic code? | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Yes |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| See diagnostic code | |||
|
|
|
| ||||
|
|
|
| troubleshooting guide | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Does Display |
|
| |||
|
|
|
|
|
|
| show "Select |
|
| |||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| Cycle"? |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Yes |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Does control board |
|
| |||
|
| No |
|
|
|
| respond to |
|
| |||
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| program keys? |
|
| |||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Yes |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Unplug dryers and check |
| ||||||
|
|
|
|
|
| wiring and termination |
| |||||
|
|
|
|
| between door switch and |
| ||||||
|
|
|
|
| control board. Replace |
| ||||||
|
|
|
|
| door switch if necessary |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| If problem |
|
| |||
|
|
|
|
|
|
| persists, initiate |
|
| |||
|
|
|
|
|
|
| reset sequence. |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| If problem |
|
| |||
|
|
|
|
|
|
| persists, replace |
|
| |||
|
|
|
|
|
|
| control board. |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
Cycle price must
No be satisfied before keypads will work.
|
|
| Unplug dyers and | |
|
|
| check problem | |
No |
|
| ||
|
| membrane switch | ||
|
|
| ||
|
|
| ||
|
|
| tail connection. | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Plug in dryer. If problem
persists replace corresponding membrane switch.
30 | 16022904 Rev. 0 | ©2004 Maytag Appliances Company |