!W ARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing requires power.

Stack Dryer Diagnostic Code

d1 or d17

Door Sense Problem

d1 indicates the upper dryer door, d17 indicates the

lower dryer door on control board or due to power line

interference

Try to Clear the

 

 

 

 

 

 

 

diagnostic code by

 

 

 

 

 

 

False

pressing the

 

Did the

 

 

 

 

indication.

Delicates keypad

 

diagnostic code

 

Yes

 

 

Control board

 

 

 

for more than 1

 

clear?

 

 

 

 

is operating

 

 

 

 

 

second while the

 

 

 

 

 

 

normally.

code is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the control board.

No

If diagnostic code still appears, the power line is noisy

and should be

tested.

d4 or d20

Motor Control Circuit

Problem

Try to Clear the

diagnostic code by

pressing the

Delicates keypad

for more than 1 second while the code is displayed.

Push the Perm Press program keypad to start the diagnostic program.

 

 

 

 

 

 

False

Did the

 

 

 

 

indication.

diagnostic code

 

No

 

 

Control board

 

 

reappear?

 

 

 

 

is operating

 

 

 

 

 

 

 

 

 

 

normally.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

Check the wiring between the control board and the motor.

Fix the power line

disturbance.

 

 

Is the power

 

 

Yes

 

line supply to the

 

No

 

 

 

 

machine noisy?

 

 

 

 

 

Replace the

control board.

d5 Blocked Coin 1

(d13 Blocked Coin 2)

Or Coin Drop Circuit

Problem

Unplug dryer and check the wiring and termination between the coin drop and the control board.

Check for an

object blocking the

coin drop optic

sensor. It takes 8 seconds for the control to recognize the blockage.

If the problem still exists, replace the coin drop coin sensor.

If the

problem still exist, replace the control board.

©2004 Maytag Appliances Company

16022904 Rev. 0

35

Image 35
Contents Commercial Single Stack Dryers Important Information Table of Contents Important Safety Information Proper Grounding and Polarization of 120 Volts Wall Outlets About Ground WiresGeneral Information Related Publications Explanation Grounding InstructionsCommercial Dryer Nomenclature ServiceParts and Accessories Model IdentificationAir movement measured in cubic feet per minute TERMINOLOGY/DEFINITIONS Term DefinitionsWater 1 o F HOW IT Works GAS Valve AssemblyRadiant Sensor Contact Closed Function of Gas Valve SystemIgnition Failures Safety FeaturesPower Interruptions Gas ConversionsGeneral Information Exhaust Ducts General SpecificationsWattage Specifications Drive Motor Check Electrical TroubleshootingDrive Motor Test Centrifugal SwitchAir Shutter Adjustment Motor Test CordManometers How to UseNoisy and/Or Vibration Mechanical Troubleshooting Will Not RunWill Not Shut-Off Will Not DrySingle Dryer Troubleshooting Guide Operator Dryer Stopped with Zero Minutes Remaining DisplayCannot Enter Or ExitDropped Into Machine Credited Are Eventually Lost Display Flashes User ModeKey Inputs Control Does NotRespond To Dryer Drum Will Not Turn To Coin 1 or ResponsePoint Is Used Will Not Keep Time Of Day During Power InterruptionsWill not Respond to handheld No DecimalDryer Will Not HeatDryer Diagnostic Program Single Dryer Diagnostic ProgramDoor Sense Problem Single Dryer Diagnostic CodeVAC Lower Dryer Has Zero Minutes Remaining Display Stack Dryer Troubleshooting GuideDisplay Is Blank Abnormal Display Or Function Upper orKeypads ControlBoard Does NotInterruption Response To Coin Or CoinKeep Time Day During Cannot Dryer Runs Without Program Selection Drum Will Not Turn Stack Dryer Diagnostic Program D1 or d17 Door Sense Problem Stack Dryer Diagnostic CodeVoltage Problem Transformer Touch Pad AssemblyControl Panel Microprocessor BoardCoin Sensor Service Door SwitchCoin Vault Switch Door AssemblyFront Panel Reversing Door AssemblyDoor Disassembly Top Cover Door SwitchOutlet Duct, Shroud & Tumbler Front Front Shroud Assembly RemovalBelt Lint FilterBearing & Pads Front SealBaffles Rear Shroud AssemblyInstalling Drive Belt Back Seal Roller and Bearing AssemblyLow-cycling Thermostat Blower AssemblyThermostats Cycling ThermostatBlower Idler Arm Assembly Exhaust Duct Pipe Assembly BreakdownMotor Switch Drive Motor Assembly Igniter Gas Valve AssemblyCoils Heater Enclosure Gas ValveCombustion Cone Inlet DuctStack Dryer Sloped Front Models Service Panel and SwitchAccess Cover Coin Drop MicroprocessorSwing Out Away Remove ScrewsStack DRYER-MN Models Stack Dryer Sloped Front PRMachine-In-Use Light Push-To-Start SwitchTimer Selector SwitchStack DRYER-FLAT Front Models Front Shroud AssemblyMotor & Heater Relays Appendix a Pricing Programming ProceduresFixed Vend Pricing SET UP Codes Money Counter Option Steps 3. thru 9. codes are skipped if mode 2.00 is selected00 7.STARTING of Special Pricing Hour Value of Coin 2 Canadian Dollar Drop White & Colors keypad Example Stacked Models Only Dryer Diagnostic ModeDryer Help Mode All Single Load Models