DRYER DIAGNOSTIC MODE
This mode is entered by depressing DELICATES for one second while in any of the
All Single Load Models:
With all segments flashing, the diagnostic cycle is started by depressing the PERMANENT PRESS key pad. The cycle consists of seven minutes of heat and 1 minute of cooldown. The WHITES & COLORS key pad will increment the diagnostic cycle minutes up to 99, then roll over to 2 minutes. The DELICATES key pad will cancel this cycle and exit the diagnostic mode.
Stacked Models Only:
There are 2 procedures to initiate cycle activity from diagnostic mode for these models:
1.Upper Dryer Field Diagnostic Cycle – With the entire display flashing, the cycle is started by pressing the UPPER DRYER PERMANENT PRESS key pad. The cycle consists of seven minutes of heat and one minute of cool down. The UPPER DRYER WHITES & COLORS key pad will increment the diagnostic cycle minutes up to 99, then roll over to 2 minutes. Pressing the LOWER DRYER DELICATES key pad will cancel this cycle and exit the diagnostic mode.
2.Lower Dryer Field Diagnostic Cycle – With entire display flashing, the cycle is started by pressing the LOWER DRYER PERMANENT PRESS key pad. The cycle consists of seven minutes of heat and one minute of cool down. The LOWER DRYER WHITES & COLORS key pad will increment the diagnostic cycle minutes up to 99, then roll over to 2 minutes. Pressing the LOWER DRYER DELICATES key pad will cancel this cycle and exit the diagnostic mode.
Dryer Help Mode
The Help Mode is entered by pressing the Whites & Colors keypad while in special pricing option, step 2.XX (or while dAS displays if operating with Maytag Data Acquisition set up). In help mode, the software revision is displayed in the digits. Press the Whites & Colors key at anytime to exit help mode.
In help mode, other display symbols and elements are mapped to reflect the state of various input and outputs as follows:
| Single Load Dryers | |
DISPLAY |
| DESCRIPTION |
* |
| Low voltage present (below 90VAC) |
Circle above digit |
| Door closed |
& |
| 140° thermostat closed |
OR |
| Motor sensed running |
AIR |
| Heater/gas valve relay on |
FLUFF |
| Motor relay on |
|
|
|
Stacked Dryer Models
Upper Dryer Only – Upper Half Of Display
| Upper dryer motor sensed running |
Circle above digit | Upper dryer door closed |
COOL | Upper dryer 140° thermostat closed |
OR | Upper dryer heater relay on |
& | Upper dryer motor relay on |
|
|
Lower Dryer Only | – Lower Half Of Display |
* | Low voltage present (below 90VAC) |
| Lower dryer motor sensed running |
Circle above digit | Lower dryer door closed |
COOL | Lower dryer 140° thermostat closed |
OR | Lower dryer heater relay on |
& | Lower dryer motor relay on |
66 | 16022904 Rev. 0 | ©2004 Maytag Appliances Company |