Kenmore 110.9756, 9757, 9758 Optional exhaust installations, Recommended exhaust installations

Page 11

Choose your exhaust installation type

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

B

A.....

................. F

...................................G

A.Dryer

B.Elbow

C.Wall

D.Exhaust hood E, Clamps

F. Rigid metal or flexible metal vent

G. Vent length necessary to connect elbows

H. Exhaust outlet

Optional exhaust installations

Fire Hazard

Cover unused exhaust holes with the following kit:

279818 (white)

Contact your local dealer.

Failure to follow these instructions can result in death, fire, electrical shock, or serious injury.

This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the

dryer converted.

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for

your installation. Two close-clearance installations are shown. Refer to the manufacturer's instructions.

i/

I II

AB

A. Over-No-top installation (also available with one offset elbow)

B. Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase. For further information, please call 1-800-4-MY-HOME® (1-800-469-4663}.

Over-the-Top Installation: Part Number 26-49900

Periscope Installation (For use with dryer vent to wall vent mismatch):

Part Number 26-49901 - Less than 5" (12.7 cm) mismatch

Part Number 26-49908 - 5" (12.7 cm) to 18" (45.72 cm) mismatch

Part Number 26-49904 - 18" (45.72 cm) to 29" (73.66 cm) mismatch

Part Number 26-49905 - 29" (73.66 cm) to 50" (127 cm) mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

AB

A. Standard rear offset exhaust installation

B. Left or right side exhaust installation

C. Bottom exhaust installation (not an option with pedestal installations)

Determine vent path

Select the route that will provide the straightest and most direct path outdoors.

Plan the installation to use the fewest number of elbows and turns.

When using elbows or making turns, allow as much room as possible.

Bend vent gradually to avoid kinking.

Use the fewest 90 ° turns possible.

11

Image 11
Contents Gas Dryer Secadora a Gas Kenmore Appliance and Optional Pedestal Warranty Table of ContentsModel number Dryer SafetyPedestal Product Record Safety Instructions Explosion Hazard Parts suppliedParts needed Stack KitCloset installation Dryer only Installation clearancesDryer Dimensions Custom undercounter installation Dryer onlyRequired spacing Installation spacing for cabinet installationMobile home additional installation requirements Grounding iNSTRUCTiONSGas supply line Gas supply pressure testingGas supply connection requirements Rigid metal vent If using an existing vent systemDryer gas pipe If this is a new vent system Vent materialClamp Special provisions for mobile home installations Optional exhaust installationsRecommended exhaust installations Alternate installations for close clearancesFor mobile home use Number Type Box or Angled Turns Vent Iouvered HoodsHoods Rigid metal Flexible MetalClosed valve Open valve Remove the door assemblyPlug strip cannot be seen from this angle Reverse hingeReverse the strike If the dryer will not start, check the following Fire Hazard Dryer USETo use an Auto Cycle Ust Wrinkle Guard NormalDry Auto Cycles Preset Settings Changing Cycles after pressing Start Cycle SignalWrinkleGuard90 Wrinkle Guard e90Dryer Care Vacation care To clean dryer drumFrom Inside the Dryer Cabinet From the Exhaust VentDryer displaying code message TroubleshootingNo heat UnusualsoundsMaster Protection Agreements Lint on load Is the lint screen clogged?Cuidado Garantia SeguridadInstrucciones USO DE LA SecadoraRegistro DE Producto DEL Pedestal Seguridad DE LA SecadoraSu seguridad y la seguridad de los demas es muy importante Registro DEL ProductoADVERTENClA Peligro de Explosi6n Piezas suministradasPatas niveladoras Piezas para adquirirInstalaci6n en el cl6set S61o secadora Dimensiones de la secadoraEspacios para la Instalacibn Las instalaciones en casas rodantes necesitan 68,6 cmEspacio minimo para la instalacibn en un armario 6 cmGas natural Tipo de gasLa linea de suministro de gas Peligro de E×plosionRequisitos de entrada del quemador Requisitos para la conexibn del suministro de gasDucto de escape de metal flexible Si este es un nuevo sistema de ventilacibnMaterial de ventilaci6n Ducto de escape de metal rigidoInstalaciones recomendadas de escape Instalaciones opcionales de escapeInstalaciones alternas para espacios limitados Seleccione su tipo de instalacibn de ventilacibnMetal Rigido Determinacibn de la via del ducto de escapeCuadro del sistema de ventilacibn Ilamar al 1-800-4-MY-HOME Invierta la bisagra C6mo quitar el ensamblaje de la puertaSi la secadora no funciona, revise Io siguiente PeligroConecte a un contacto de pared de conexion a tierra de Vuelva a instalar la puertaPara usar un ciclo de secado automatico USO DE LA SecadoraPara activar la caracteristica de bloqueo de controles Dryness LevelPara usar un ciclo programado Timed Normal Timed DryHeavyDuty Touch Up Auto CyclesTouch Ropa delicada DelicateAjustes prefijados de ciclos automaticos DRYCambio de ciclos despus de presionar puesta en marcha WrinkleGuard90 YcleSignalCuando use s61o aire Sehal de cicloImportante Sonidos raros Solucion DE ProblemasLa secadora No funciona Sin calor El tiempo del ciclo es demasiado corto La secadora muestra mensajes codificadosContratos Maestros de Proteccibn ProteccionPelusa en la ropa Esta obstruido el filtro de pelusa? Sears