Kenmore 9757, 9758 Dryer gas pipe, If using an existing vent system, Rigid metal vent, Elbows

Page 9

Dryer gas pipe

The gas pipe that comes out through the rear of your dryer has a %" male pipe thread.

B

(15.9 cm)

A. Y2" NPT gas supply line

B. %" NPT dryer pipe

*NOTE: If the dryer is mounted on a pedestal, the gas pipe height must be an additional 10" (25.4 cm) from the floor. For a garage installation, the gas pipe height must be an additional

18" (46 cm) from the floor.

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling or a concealed space of a building.

If using an existing vent system

Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint.

Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.

Review Vent system chart. Modify existing vent system if necessary to achieve the best drying performance.

If this is a new vent system

Vent material

Use a heavy metal vent. Do not use plastic or metal foil vent.

4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFF Mventing products are recommended.

4" (lO.2 cm) heavymetal exhaust vent

DURASAFF Mvent products can be purchased from your dealer. For further information, please call

1-800-4-MY-HOME ® (1-800-469-4863} or visit our website at

www.sears.com.

Rigid metal vent

For best drying performance, rigid metal vents are recommended.

Rigid metal vent is recommended to avoid crushing and kinking.

Flexible metal vent

Flexible metal vents are acceptable only if accessible for cleaning.

Flexible metal vent must be fully extended and supported when the dryer is in its final location.

Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.

Do not install flexible metal vent in enclosed walls, ceilings or floors.

Elbows

45 ° elbows provide better airflow than 90 ° elbows.

GoodBetter

Image 9
Contents Gas Dryer Secadora a Gas Kenmore Appliance and Optional Pedestal Warranty Table of ContentsDryer Safety Pedestal Product RecordModel number Safety Instructions Parts needed Parts suppliedStack Kit Explosion HazardDryer Dimensions Installation clearancesCustom undercounter installation Dryer only Closet installation Dryer onlyMobile home additional installation requirements Installation spacing for cabinet installationGrounding iNSTRUCTiONS Required spacingGas supply pressure testing Gas supply connection requirementsGas supply line Dryer gas pipe If using an existing vent systemIf this is a new vent system Vent material Rigid metal ventClamp Recommended exhaust installations Optional exhaust installationsAlternate installations for close clearances Special provisions for mobile home installationsHoods Rigid metal Number Type Box or Angled Turns Vent Iouvered HoodsFlexible Metal For mobile home useClosed valve Open valve Remove the door assemblyReverse hinge Reverse the strikePlug strip cannot be seen from this angle If the dryer will not start, check the following Dryer USE To use an Auto CycleFire Hazard Ust Normal DryWrinkle Guard Auto Cycles Preset Settings WrinkleGuard90 Cycle SignalWrinkle Guard e90 Changing Cycles after pressing StartDryer Care From Inside the Dryer Cabinet To clean dryer drumFrom the Exhaust Vent Vacation careNo heat TroubleshootingUnusualsounds Dryer displaying code messageMaster Protection Agreements Lint on load Is the lint screen clogged?Instrucciones Garantia SeguridadUSO DE LA Secadora CuidadoSu seguridad y la seguridad de los demas es muy importante Seguridad DE LA SecadoraRegistro DEL Producto Registro DE Producto DEL PedestalADVERTENClA Patas niveladoras Piezas suministradasPiezas para adquirir Peligro de Explosi6nDimensiones de la secadora Espacios para la InstalacibnInstalaci6n en el cl6set S61o secadora Espacio minimo para la instalacibn en un armario 68,6 cm6 cm Las instalaciones en casas rodantes necesitanLa linea de suministro de gas Tipo de gasPeligro de E×plosion Gas naturalRequisitos de entrada del quemador Requisitos para la conexibn del suministro de gasMaterial de ventilaci6n Si este es un nuevo sistema de ventilacibnDucto de escape de metal rigido Ducto de escape de metal flexibleInstalaciones alternas para espacios limitados Instalaciones opcionales de escapeSeleccione su tipo de instalacibn de ventilacibn Instalaciones recomendadas de escapeDeterminacibn de la via del ducto de escape Cuadro del sistema de ventilacibnMetal Rigido Ilamar al 1-800-4-MY-HOME Invierta la bisagra C6mo quitar el ensamblaje de la puertaConecte a un contacto de pared de conexion a tierra de PeligroVuelva a instalar la puerta Si la secadora no funciona, revise Io siguientePara usar un ciclo de secado automatico USO DE LA SecadoraDryness Level Para usar un ciclo programadoPara activar la caracteristica de bloqueo de controles HeavyDuty Touch Up Normal Timed DryAuto Cycles TimedAjustes prefijados de ciclos automaticos Ropa delicada DelicateDRY TouchCuando use s61o aire WrinkleGuard90 YcleSignalSehal de ciclo Cambio de ciclos despus de presionar puesta en marchaImportante Solucion DE Problemas La secadora No funciona Sin calorSonidos raros El tiempo del ciclo es demasiado corto La secadora muestra mensajes codificadosProteccion Pelusa en la ropa Esta obstruido el filtro de pelusa?Contratos Maestros de Proteccibn Sears