Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut=off valve.

Securely tighten all gas connections.

if connected to LP, have a qualified person make sure

gas pressure does not exceed 13" (33 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to de so can result in death, explosion, or fire.

Gas Type

Natural gas:

This dryer is equipped for use with Natural gas. It is design- certified by CSA International for LP (propane or butane) gases with appropriate conversion.

Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not

agree with the type of gas available, contact your local Sears store or Sears Service Center.

LP gas conversion:

Conversion must be made by a qualified technician.

No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company.

Gas supply line

Must include r/s" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer (see illustration).

V2" IPS pipe is recommended.

%" approved aluminum or copper tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit.

If you are using Natural gas, do not use copper tubing.

%" flare x %" NPT adapter fitting between dryer pipe and %" approved tubing.

Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting.

If your dryer has been converted to use LP gas, %" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger pipe.

NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON _t tape.

Must include a shutoff valve:

An individual manual shutoff valve must be installed in

accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual

manual shutoff valve be installed within six (6) feet (1.8 m) of the dryer and the location be easy to reach for opening and closing.

AC E

BD

A. %" flexible gas connector

B. _" pipe to flare adapter fitting

C. _" NPT minimum plugged tapping

D._2"NPT gas supply line E.Gas shutoff valve

Gas supply connection requirements

Use an elbow and a %" flare x %" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking.

Use only pipe-joint compound. Do not use TEFLON _ tape.

This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, CSA 6.10.

Burner input requirements

Elevations above 10,000 ft (3,048 m):

When installed above 10,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation.

Gas supply pressure testing

The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than _/_psi.

_®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

Image 8
Contents Gas Dryer Secadora a Gas Table of Contents Kenmore Appliance and Optional Pedestal WarrantyModel number Dryer SafetyPedestal Product Record Safety Instructions Parts supplied Parts neededStack Kit Explosion HazardInstallation clearances Dryer DimensionsCustom undercounter installation Dryer only Closet installation Dryer onlyInstallation spacing for cabinet installation Mobile home additional installation requirementsGrounding iNSTRUCTiONS Required spacingGas supply line Gas supply pressure testingGas supply connection requirements If using an existing vent system Dryer gas pipeIf this is a new vent system Vent material Rigid metal ventClamp Optional exhaust installations Recommended exhaust installationsAlternate installations for close clearances Special provisions for mobile home installationsNumber Type Box or Angled Turns Vent Iouvered Hoods Hoods Rigid metalFlexible Metal For mobile home useRemove the door assembly Closed valve Open valvePlug strip cannot be seen from this angle Reverse hingeReverse the strike If the dryer will not start, check the following Fire Hazard Dryer USETo use an Auto Cycle Ust Wrinkle Guard NormalDry Auto Cycles Preset Settings Cycle Signal WrinkleGuard90Wrinkle Guard e90 Changing Cycles after pressing StartDryer Care To clean dryer drum From Inside the Dryer CabinetFrom the Exhaust Vent Vacation careTroubleshooting No heatUnusualsounds Dryer displaying code messageLint on load Is the lint screen clogged? Master Protection AgreementsGarantia Seguridad InstruccionesUSO DE LA Secadora CuidadoSeguridad DE LA Secadora Su seguridad y la seguridad de los demas es muy importanteRegistro DEL Producto Registro DE Producto DEL PedestalADVERTENClA Piezas suministradas Patas niveladorasPiezas para adquirir Peligro de Explosi6nInstalaci6n en el cl6set S61o secadora Dimensiones de la secadoraEspacios para la Instalacibn 68,6 cm Espacio minimo para la instalacibn en un armario6 cm Las instalaciones en casas rodantes necesitanTipo de gas La linea de suministro de gasPeligro de E×plosion Gas naturalRequisitos para la conexibn del suministro de gas Requisitos de entrada del quemadorSi este es un nuevo sistema de ventilacibn Material de ventilaci6nDucto de escape de metal rigido Ducto de escape de metal flexibleInstalaciones opcionales de escape Instalaciones alternas para espacios limitadosSeleccione su tipo de instalacibn de ventilacibn Instalaciones recomendadas de escapeMetal Rigido Determinacibn de la via del ducto de escapeCuadro del sistema de ventilacibn Ilamar al 1-800-4-MY-HOME C6mo quitar el ensamblaje de la puerta Invierta la bisagraPeligro Conecte a un contacto de pared de conexion a tierra deVuelva a instalar la puerta Si la secadora no funciona, revise Io siguienteUSO DE LA Secadora Para usar un ciclo de secado automaticoPara activar la caracteristica de bloqueo de controles Dryness LevelPara usar un ciclo programado Normal Timed Dry HeavyDuty Touch UpAuto Cycles TimedRopa delicada Delicate Ajustes prefijados de ciclos automaticosDRY TouchWrinkleGuard90 YcleSignal Cuando use s61o aireSehal de ciclo Cambio de ciclos despus de presionar puesta en marchaImportante Sonidos raros Solucion DE ProblemasLa secadora No funciona Sin calor La secadora muestra mensajes codificados El tiempo del ciclo es demasiado cortoContratos Maestros de Proteccibn ProteccionPelusa en la ropa Esta obstruido el filtro de pelusa? Sears