Kenmore 110.8709, 110.8708 Wire connection Power supply cord, Style 2 Direct wire strain relief

Page 10

Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.

Style 2: Direct wire strain relief

Unscrew the removable conduit connector and any screws from a ³⁄₄" (1.9 cm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief through the hole below the terminal block opening. Reaching inside the terminal block opening, screw the removable conduit connector onto the strain relief threads.

A

B

C

A. Removable conduit connector

B. Hole below terminal block opening

C. Strain relief threads

Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.

4.Now complete installation following instructions for your type of electrical connection:

4-wire(recommended)

3-wire(if 4-wire is not available)

Electrical Connection Options

If your home has:

And you will be

Go to Section

 

connecting to:

 

4-wire receptacle

A UL listed, 120/

4-wire connection:

(NEMA Type 14-30R)

240-volt

Power supply cord

 

minimum,

 

 

30-amp, dryer

 

 

power supply

 

 

cord*

 

4-wire direct

A fused

4-wire connection:

 

disconnect or

Direct Wire

 

circuit breaker

 

5"

box*

 

 

 

(12.7 cm)

 

 

3-wire receptacle

A UL listed, 120/

3-wire connection:

(NEMA type 10-30R)

240-volt

Power supply cord

 

minimum,

 

 

30-amp, dryer

 

 

power supply

 

 

cord*

 

3-wire direct

A fused

3-wire connection:

 

disconnect or

Direct Wire

 

circuit breaker

 

3¹⁄₂"

box*

 

(8.9 cm)

 

 

*If local codes do not permit the connection of a cabinet-ground conductor to the neutral wire, go to “Optional 3-wire connection” section.

4-wire connection: Power supply cord

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

BF

A

C DEG

A.4-wire receptacle (NEMA type 14-30R) B. 4-prong plug

C. Ground prong D. Neutral prong

E. Spade terminals with upturned ends F. ¾" (1.9 cm) UL listed strain relief G. Ring terminals

10

Image 10 Contents
Electric Dryer Table of Contents Protection AgreementsKenmore Elite Appliance Warranty ONE Year Limited WarrantyDryer Safety Your safety and the safety of others are very importantTools and Parts Installation InstructionsOptional Pedestal Custom undercounter installation Dryer only Installation clearancesDryer Dimensions Location RequirementsCloset installation Dryer only Installation spacing for cabinet installationMobile home additional installation requirements Dimensions shown are for the recommended spacingIt is your responsibility Electrical RequirementsElectrical Connection Style 1 Power supply cord strain relief Power Supply Cord Direct WireInstall strain relief Electrical ConnectionWire connection Power supply cord Style 2 Direct wire strain reliefWire connection Direct wire Remove center silver-colored terminal block screwBDE CG F Optional 3-wire connection Venting Requirements If using an existing vent systemIf this is a new vent system Vent material Plan Vent System Optional exhaust installationsAlternate installations for close clearances Angled hood style shown here is acceptableSpecial provisions for mobile home installations Install Vent SystemInstall Leveling Legs Vent system chartReverse Door Swing Connect VentLevel Dryer Remove the doorReverse the door handle Complete InstallationReinstalling the door If the dryer will not start, check the followingTo use an Auto Cycle Dryer USEStarting Your Dryer To make changes during an Auto CycleControl Locked Pausing or RestartingStopping Your Dryer Drying and Cycle TipsStatus Lights CyclesTimed Dry Auto Dry Preset Cycle SettingsTimed Preset Cycle Settings Touch UpOptions Changing Cycles, Options and ModifiersEnd of Cycle Signal End of Cycle SignalChanging the Preset Dryness Level Settings Tumble Free Heated Dryer RackDryer Care Changing the Drum Light TroubleshootingDryer Operation Dryer Results Contratos Maestros de Protección ÍndiceContratos DE Protección Servicio de Instalación de SearsGarantía DE LOS Electrodomésticos Kenmore Elite Garantía Limitada DE UN AÑOSeguridad DE LA Secadora Su seguridad y la seguridad de los demás es muy importantePedestal opcional Instrucciones DE InstalaciónHerramientas y piezas Requisitos de ubicaciónEspacio necesario Dimensiones de la secadoraEspacios para la instalación Instalación en el clóset Sólo secadoraUsted es responsable de Requisitos eléctricosEspacio para la instalación en un armario Las instalaciones en casas rodantes necesitanSi emplea un cable de suministro eléctrico Conexión eléctricaDeberá usarse una conexión con suministro de energía de Si el contacto de pared luce como ésteCable directo Conexión eléctricaCable de suministro eléctrico Instale el protector de cablesEstilo 2 Protector de cables para cable directo Conexión de 4 hilos Cable de suministro eléctricoAprobado de UL Conexión de 4 hilos Cable directo Tornillo conductor de tierra externoConexión de 3 hilos Cable de suministro eléctrico Conexión de 3 hilos Cable directoConexión opcional de 3 hilos Si usa un sistema de ventilación existente Requisitos de ventilaciónSi éste es un nuevo sistema de ventilación Instalaciones opcionales de escape Instalaciones alternas para espacios limitadosDeterminación de la vía del ducto de escape Instalación del sistema de ventilaciónCuadro del sistema de ventilación Nivelación de la secadora Instalación de las patas niveladorasConexión del ducto de escape Inversión del cierre de la puertaInversión de la manija de la puerta Inversión de la bisagraPonga a un lado el conjunto interno de la puerta Reinstalación de la puerta Complete la instalaciónSi la secadora no funciona, revise lo siguiente Para usar un ciclo de secado automático USO DE LA SecadoraPuesta en marcha de la secadora Seleccione las opciones deseadasControl bloqueado Detención de la marcha De la secadoraPausa o reanudación de la marcha Sugerencias de ciclos y secadoLuces de estado CiclosInformal Casual Pantalones de mezclilla JeansArtículos voluminosos/Ropa de cama Bulky/Bedding Ropa ultradelicada Ultra DelicateOpciones ModificadoresSeñal de fin de ciclo Cambio de ciclos, opciones y ModificadoresEstante térmico de la secadora Limpieza del filtro de pelusa Cuidado DE LA SecadoraLimpieza de cada carga Eliminación de pelusa acumulada Limpieza del interior de la secadoraCuidado para las vacaciones y la mudanza Funcionamiento de la secadora Solución DE ProblemasCambio de la luz del tambor Resultados de la secadoraManchas en la carga o en el tambor El tiempo del ciclo es demasiado cortoPelusa en la ropa Ropa arrugadaW10035610