The angled hood style (shown here) is acceptable.

4"

(10.2 cm)

2½" (6.4 cm)

An exhaust hood should cap the vent to keep rodents and insects from entering the home.

Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).

Do not use an exhaust hood with a magnetic latch.

Improper venting can cause moisture and lint to collect indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

Housecleaning problems and health problems.

Plan Vent System

Choose your exhaust installation type

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

 

B

 

C

 

D

A

E

 

F

 

G

 

H

A. Dryer

E. Clamps

B. Elbow

F. Rigid metal or flexible metal vent

C. Wall

G. Vent length necessary to connect elbows

D. Exhaust hood

H. Exhaust outlet

Optional exhaust installations

This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the dryer converted.

WARNING

Fire Hazard

Cover unused exhaust holes with one of the following kits:

279818 (white)

279915 (black diamond)

280102 (pacific blue)

280103 (champagne)

280189 (barolo)

Contact your local dealer.

Failure to follow these instructions can result in death, fire, electrical shock, or serious injury.

ABC

A. Standard rear offset exhaust installation B. Left or right side exhaust installation

C. Bottom exhaust installation (not an option with pedestal installations)

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.

AB

A. Over-the-top installation (also available with one offset elbow) B. Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase. For further information, please call 1-800-4-MY-HOME®(1-800-469-4663).

15

Image 15 Contents
Electric Dryer Protection Agreements Table of ContentsONE Year Limited Warranty Kenmore Elite Appliance WarrantyYour safety and the safety of others are very important Dryer SafetyInstallation Instructions Tools and PartsOptional Pedestal Location Requirements Installation clearancesDryer Dimensions Custom undercounter installation Dryer onlyDimensions shown are for the recommended spacing Installation spacing for cabinet installationMobile home additional installation requirements Closet installation Dryer onlyElectrical Requirements It is your responsibilityElectrical Connection Electrical Connection Power Supply Cord Direct WireInstall strain relief Style 1 Power supply cord strain reliefStyle 2 Direct wire strain relief Wire connection Power supply cordRemove center silver-colored terminal block screw Wire connection Direct wireBDE CG F Optional 3-wire connection If using an existing vent system Venting RequirementsIf this is a new vent system Vent material Angled hood style shown here is acceptable Optional exhaust installationsAlternate installations for close clearances Plan Vent SystemVent system chart Install Vent SystemInstall Leveling Legs Special provisions for mobile home installationsRemove the door Connect VentLevel Dryer Reverse Door SwingIf the dryer will not start, check the following Complete InstallationReinstalling the door Reverse the door handleTo make changes during an Auto Cycle Dryer USEStarting Your Dryer To use an Auto CycleDrying and Cycle Tips Pausing or RestartingStopping Your Dryer Control LockedCycles Status LightsTouch Up Auto Dry Preset Cycle SettingsTimed Preset Cycle Settings Timed DryChanging Cycles, Options and Modifiers OptionsTumble Free Heated Dryer Rack End of Cycle SignalChanging the Preset Dryness Level Settings End of Cycle SignalDryer Care Troubleshooting Changing the Drum LightDryer Operation Dryer Results Servicio de Instalación de Sears ÍndiceContratos DE Protección Contratos Maestros de ProtecciónGarantía Limitada DE UN AÑO Garantía DE LOS Electrodomésticos Kenmore EliteSu seguridad y la seguridad de los demás es muy importante Seguridad DE LA SecadoraRequisitos de ubicación Instrucciones DE InstalaciónHerramientas y piezas Pedestal opcionalInstalación en el clóset Sólo secadora Dimensiones de la secadoraEspacios para la instalación Espacio necesarioLas instalaciones en casas rodantes necesitan Requisitos eléctricosEspacio para la instalación en un armario Usted es responsable deSi el contacto de pared luce como éste Conexión eléctricaDeberá usarse una conexión con suministro de energía de Si emplea un cable de suministro eléctricoInstale el protector de cables Conexión eléctricaCable de suministro eléctrico Cable directoConexión de 4 hilos Cable de suministro eléctrico Estilo 2 Protector de cables para cable directoAprobado de UL Tornillo conductor de tierra externo Conexión de 4 hilos Cable directoConexión de 3 hilos Cable directo Conexión de 3 hilos Cable de suministro eléctricoConexión opcional de 3 hilos Requisitos de ventilación Si usa un sistema de ventilación existenteSi éste es un nuevo sistema de ventilación Instalaciones alternas para espacios limitados Instalaciones opcionales de escapeInstalación del sistema de ventilación Determinación de la vía del ducto de escapeCuadro del sistema de ventilación Inversión del cierre de la puerta Instalación de las patas niveladorasConexión del ducto de escape Nivelación de la secadoraInversión de la bisagra Inversión de la manija de la puertaPonga a un lado el conjunto interno de la puerta Complete la instalación Reinstalación de la puertaSi la secadora no funciona, revise lo siguiente Seleccione las opciones deseadas USO DE LA SecadoraPuesta en marcha de la secadora Para usar un ciclo de secado automáticoSugerencias de ciclos y secado Detención de la marcha De la secadoraPausa o reanudación de la marcha Control bloqueadoCiclos Luces de estadoRopa ultradelicada Ultra Delicate Pantalones de mezclilla JeansArtículos voluminosos/Ropa de cama Bulky/Bedding Informal CasualModificadores OpcionesCambio de ciclos, opciones y Modificadores Señal de fin de cicloEstante térmico de la secadora Cuidado DE LA Secadora Limpieza del filtro de pelusaLimpieza de cada carga Limpieza del interior de la secadora Eliminación de pelusa acumuladaCuidado para las vacaciones y la mudanza Resultados de la secadora Solución DE ProblemasCambio de la luz del tambor Funcionamiento de la secadoraRopa arrugada El tiempo del ciclo es demasiado cortoPelusa en la ropa Manchas en la carga o en el tamborW10035610