Maytag W10160251A Gas Supply Line Gas supply connection requirements, Burner Input Requirements

Page 8

Gas Supply Line:

 

Gas supply connection requirements

Must include ¹⁄₈" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer (see illustration).

¹⁄₂" IPS pipe is recommended.

³⁄₈" approved aluminum or copper tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit.

If you are using Natural gas, do not use copper tubing.

³⁄₈" flare x ³⁄₈" NPT adapter fitting between dryer pipe and ³⁄₈" approved tubing.

Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting.

If your dryer has been converted to use LP gas, ³⁄₈" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger pipe.

NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape.

Must include a shutoff valve:

In the U.S.A.:

An individual manual shutoff valve must be installed within six (6) feet (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1.

In Canada:

An individual manual shutoff valve must be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual manual shutoff valve be installed within six (6) feet (1.8 m) of the dryer.

The location should be easy to reach for opening and closing.

A C E

BD

A. ³⁄₈" flexible gas connector

B. ³⁄₈" pipe to flare adapter fitting

C. ¹⁄₈" NPT minimum plugged tapping

D. ½" NPT gas supply line

E. Gas shutoff valve

Use an elbow and a ³⁄₈" flare x ³⁄₈" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking.

Use only pipe-joint compound. Do not use TEFLON®† tape.

This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.

Burner Input Requirements:

Elevations above 10,000 ft (3,048 m):

When installed above 10,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation.

Gas Supply Pressure Testing

The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than ½ psi.

Dryer Gas Pipe

The gas pipe that comes out through the rear of your dryer has a ³⁄₈" male pipe thread.

2"

(5.1 cm)

A

³⁄₄"

 

(1.9 cm)

A. ³⁄₈" NPT dryer pipe

®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

8

Image 8
Contents Guide D’UTILISATION ET D’ENTRETIEN W10160251ATable of Contents Table DES MatièresDryer Safety Your safety and the safety of others are very importantImportant Safety Instructions Location Requirements Installation InstructionsTools and Parts Installation Clearances Mobile home Additional installation requirementsMobile home installations require Dryer DimensionsElectrical Requirements Gas Supply RequirementsGas Type Natural GasDryer Gas Pipe Gas Supply Line Gas supply connection requirementsBurner Input Requirements If this is a new vent system Vent material If using an existing vent systemVenting Requirements Choose your exhaust installation type Recommended exhaust installationsPlan Vent System ExhaustInstall Vent System Alternate installations for close clearancesVent system chart Special provisions for mobile home installationsFor mobile home use Install Leveling LegsMake Gas Connection Connect Vent Connect Inlet HoseReverse Door Swing Remove the door assemblyLevel Dryer Reinstall the door Reverse the strikeComplete Installation If the dryer will not start, check the followingDryer USE Starting Your DryerTo use a Sensor Dry Cycle To make changes during a Sensor Dry CycleHow the Sensi-Care Drying System Works To use a Timed CycleStatus Lights Stopping, Pausing or RestartingDrying and Cycle Tips Cycles Modifiers Changing Cycles, Modifiers and Options End of Cycle SignalOptions Rack Dry Setting Temp Time Wool Sweaters Drying Rack OptionTo use the drying rack Stuffed toys or pillowsDryer Care Vacation, Storage and Moving Care Changing the Drum LightTroubleshooting Dryer OperationCycle time too short Lint on loadStains on load or drum Loads are wrinkledAssistance or Service AccessoriesU.S.A CanadaMaytag Corporation Major Appliance Warranty ONE Year Limited WarrantySécurité DE LA Sécheuse Votre sécurité et celle des autres est très importanteQUE Faire Dans LE CAS D’UNE Odeur DE GAZ Importantes Instructions DE Sécurité Outillage et pièces Instructions D’INSTALLATIONExigences d’emplacement Dégagements de séparation à respecter Dimensions de la sécheuseLinstallation dans une maison mobile exige Spécifications électriques Alimentation en gazType de gaz Gaz naturelCaractéristiques d’alimentation du brûleur Canalisation d’arrivée de gaz de la sécheuseAltitudes supérieures à 10 000 pi 3 048 m Épreuve sous pression de l’alimentation en gazExigences concernant lévacuation En cas dutilisation du système dévacuation existantConduit métallique rigide Conduit métallique flexibleÉvacuation Planification du système d’évacuationBrides de serrage Autres installations où le dégagement est réduit Déterminer litinéraire dacheminement du conduitTableau des systèmes dévacuation Nombre de Type de Clapets de typeInstallation du système d’évacuation Installation des pieds de nivellementRaccordement au gaz Pour utilisation dans une maison mobileRaccordement du conduit d’évacuation Raccordement des tuyaux dalimentationDépose de la porte Réglage de laplomb de la sécheuseInversion du sens douverture de la porte Réinstallation de la porte Inversion de la gâcheFermer la porte vérifier l’engagement de la gâche Achever l’installation Si la sécheuse ne démarre pas, vérifier ce qui suitUtilisation DE LA Sécheuse Mise en marche de la sécheuseUtilisation dun programme de séchage par détection Fonctionnement du système de séchage Sensi-CareUtilisation dun programme minuté Utilisation d’un programme vapeurTémoins lumineux Arrêt, pause ou remise en marcheConseils pour le séchage et les programmes Programmes Modificateurs Signal de fin de programme Modification des préréglages de niveau de séchage Changement des programmes, modificateurs et optionsChangement des programmes après avoir appuyé sur Start Option de grille de séchage Utilisation de la grille de séchageSéchage sur grille Réglage Temp Durée Chandails en laine Jouets rembourrés ou oreillersNettoyage de lemplacement de la sécheuse Entretien DE LA SécheuseNettoyage du filtre à charpie Nettoyage de l’intérieur de la sécheuseRetrait de la charpie accumulée Tuyaux darrivée deauEntreposage ou un déménagement Changement de l’ampoule d’éclairage du tambourRésultats de la sécheuse DépannageFonctionnement de la sécheuse Temps de programme trop court Charpie sur la chargeTaches sur la charge ou sur le tambour Charges avec faux plisAu Canada Assistance OU ServiceAccessoires Garantie DES Gros Appareils Ménagers Maytag Corporation W10160251A SP PN W10163137A Tous droits réservés