Install Leveling Legs

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.

1.To protect the floor, use a large flat piece of cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer.

2.Firmly grasp the body of the dryer (not the console panel). Gently lay the dryer on the cardboard. See illustration.

Make Gas Connection

1.Remove the red cap from the gas pipe.

2.Using a wrench to tighten, connect the gas supply to the dryer. Use pipe-joint compound on the threads of all non-flared male fittings. If flexible metal tubing is used, be sure there are no kinks.

A B

A. Flared male fitting

B. Non-flared male fitting

NOTE: For LP gas connections, you must use pipe-joint compound resistant to the action of LP gas. Do not use TEFLON®† tape.

A combination of pipe fittings must be used to connect the dryer to the existing gas line. Shown is a recommended connection. Your connection may be different, according to the supply line type, size and location.

3.

Examine the leveling legs. Find the diamond marking.

4.

Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the

A

B

D

C

diamond marking is no longer visible.

5. Place a carton corner post from dryer packaging under each of the 2 dryer back corners.

Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location.

Leave enough room to connect the exhaust vent.

A. 3/8flexible gas connector

B. 3/8dryer pipe

C. 3/8to 3/8pipe elbow

D.3/8pipe-to-flare adapter fitting

®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

14

Image 14
Contents Sécheuse À GAZ W10057354ATable of Contents Table DES MatiéresDryer Safety Your safety and the safety of others are very importantImportant Safety Instructions Optional Pedestal Installation InstructionsTools and Parts Custom undercounter installation Dryer only Installation clearancesDryer Dimensions Location RequirementsRecessed or closet installation Dryer on pedestal Recommended installation spacing for cabinet installationCloset installation Dryer only Electrical Requirements Mobile home Additional installation requirementsMobile home installations require Gas supply line Gas Supply RequirementsGas Type Venting Requirements Exhaust Elbows Clamps Optional exhaust installations Alternate installations for close clearancesSpecial provisions for mobile home installations Install Vent SystemVent system chart Determine vent pathExamine the leveling legs. Find the diamond marking Install Leveling LegsMake Gas Connection Connect Vent Connect Inlet HoseIf the dryer will not start, check the following Complete InstallationLevel Dryer To use a Sensor Cycle Dryer USEStarting Your Dryer How Sensor Cycles Work To use a Timed CycleControl Lock Pausing or RestartingStopping Your Dryer Drying and Cycle TipsStatus Indicator CyclesSteam Preset Cycle Settings Sensor Cycle SettingsManual Preset Cycle Settings Timed CyclesOptional Features Changing Cycles, Options and ModifiersDrying Rack Option Cleaning the Dryer Interior Cleaning the Dryer LocationCleaning the Lint Screen Dryer CareChanging the Drum Light Water Inlet HosesVacation, Storage and Moving Care Troubleshooting Dryer Operation„ Are fabric softener sheets blocking the grille? „ Was the Air Dry temperature setting selected?Dryer Results „ Is the exhaust vent the correct length?Stains on load or drum Cycle time too shortLint on load Loads are wrinkledU.S.A Assistance or ServiceIf you need replacement parts CanadaMaytag Major Appliance Warranty This limited warranty does not coverSécurité DE LA Sécheuse Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Pièces nécessaires Instructions DinstallationPiédestal facultatif Hauteur du piédestal Couleur Pièce n 10 25,4 cmExigences demplacement Espacement recommandé pour linstallation dans un placard Installation dans un placard Sécheuse seulementLinstallation dans une maison mobile exige Spécifications électriquesExigences concernant le raccordement au gaz Type de gazGaz naturel Canalisation d’arrivée de gaz de la sécheuse Exigences concernant lévacuationCaractéristiques d’alimentation du brûleur En cas dutilisation du système dévacuation existantCoudes Conduit métallique rigideConduit métallique flexible Brides de serragePlanification du système d’évacuation Installations d’évacuation facultativesAutres installations où le dégagement est réduit Déterminer litinéraire dacheminement du conduit Tableau des systèmes dévacuationInstallation des pieds de nivellement Raccordement au gazRaccordement du tuyau dalimentation Raccordement du conduit d’évacuationSi la sécheuse ne démarre pas, vérifier ce qui suit Achever l’installationMise à niveau de la sécheuse Utilisation DE LA Sécheuse Utilisation dun programme de détectionUtilisation dun programme minuté Comment fonctionnent les programmes de détectionPause ou remise en marche Verrouillage des commandesArrêt de la sécheuse Conseils pour les programmes Témoins lumineuxProgrammes Caractéristiques supplémentaires Changement des programmes, options et Modificateurs Grille de séchage Utilisation de la grille de séchageNettoyage du filtre à charpie Nettoyage de lemplacement de La sécheuseEntretien DE LA Sécheuse Nettoyage à chaque chargeTuyaux darrivée deau Nettoyage de l’intérieur de la sécheuseRetrait de la charpie accumulée Entreposage ou un déménagementChangement de l’ampoule d’éclairage Du tambour Changement de l’ampoule du tambourRésultats de la sécheuse DépannageFonctionnement de la sécheuse Taches sur la charge ou sur le tambour Assistance OU ServiceCharpie sur la charge Charges froisséesPour plus d’assistance Si vous avez besoin de pièces de rechangePour plus dassistance Nos consultants fournissent de lassistance pourGarantie DES Gros Appareils Ménagers Maytag La présente garantie limitée ne couvre pasW10057354A