Kenwood TS-590S instruction manual 63/$, $5$03/,,5&21752, 81&7,216

Page 61

23(5$725&219(1,(1&(6

',63/$<

%5,*+71(66

The brightness of the LCD display can be selected from OFF, and 1 to 6 .

1Press [MENU], then press [Q-M.IN]/ [Q-MR]or turn the MULTI/CH control to access Menu No. 00.

2Press [M.IN]/ [SCAN (SG.SEL)] to select “oFF”, “1”, “2”, “3”, “4”, “5”, or “6”.

3Press [MENU] to exit Menu mode.

%$&./,*+7&2/25

You can manually change the display illumination to suit the lighting conditions where you are operating.

1Press [MENU], then press [Q-M.IN]/ [Q-MR]or turn the MULTI/CH control to select Menu No. 01.

2Press [M.IN]/ [SCAN (SG.SEL)] to select “1” (amber) or “2” (green).

3Press [MENU] to exit Menu mode.

3$1(/.(<'28%/()81&7,21 5(63216(7,0(

You can set the response time of double function panel keys to normal or fast. The default setting is normal.

1Press [MENU], then press [Q-M.IN]/ [Q-MR]or turn the MULTI/CH control to select Menu No. 02.

2Press [M.IN]/ [SCAN (SG.SEL)] to select “1” (0.2 second), “2” (0.5 second) or “3” (1 second)

3Press [MENU] to exit Menu mode.

/,1($5$03/,),(5&21752/

When you connect an external HF or 50 MHz linear amplifier to the transceiver using the REMOTE connector, select “1”, “2”, or “3” to activate the internal relay and/ or DC output (12 V) so you can interface with the HF/ 50 MHz linear amplifier. The DC output (12 V) works without any annoying chattering sounds (“1”) but the output current is limited to 10 mA. If your linear amplifier control circuit draws more than DC 12 V/ 10 mA, use relay switching (“2” or “3”) instead.

Also, some linear amplifiers require a long transmission delay time because of the slow antenna relay switching time. In this case, select “3” for slow switching (25 ms delay).

1Press [MENU], then press [Q-M.IN]/ [Q-MR]or turn the MULTI/CH control to select Menu No. 53 (HF) or 54 (50 MHz).

2Press [M.IN]/ [SCAN (SG.SEL)] to select “oFF”, “1”, “2”, or “3”.

3Press [MENU] to exit Menu mode.

Parameter

Linear Amp. Control

oFF

All controls

Disabled

 

 

 

 

DC output (12 V)

Enabled

 

 

 

1

Relay

Disabled

 

 

 

 

TX delay

10 ms

 

 

 

 

DC output (12 V)

Enabled

 

 

 

2

Relay

Enabled

 

 

 

 

TX delay

10 ms

 

 

 

 

DC output (12 V)

Enabled

 

 

 

3

Relay

Enabled

 

 

 

 

TX delay

25 ms

 

 

 

Note: If CW Full Break-in is enabled, 10 ms transmission delay is applied regardless of the settings in Menu Nos. 53 and 54.

/2&.)81&7,216

)5(48(1&</2&.)81&7,21

Frequency Lock disables some keys and controls to prevent you from accidentally activating a function or changing the current settings.

Press and hold [FINE (F.LOCK)] to turn the Frequency Lock function ON or OFF.

” appears while this function is ON.

The following keys and controls are disabled by Frequency Lock:

Key

Comments

Tuning control

Still operates in TF-SET mode.

 

 

MULTI/CH

Still operates for changing setting

control

modes.

 

 

[ENT]

 

 

 

[M.IN]

Still operates for character

selection and for changing setting

 

modes.

 

Still operates for character

[SCAN]

selection and for changing setting

modes. Also still operates for

 

setting up scan groups (press

 

and hold).

 

 

 

Still operates in TF-SET mode

Mic [UP]

(in VFO mode) during Menu

mode when the mic key paddle

 

 

operation is ON.

 

 

 

Still operates in TF-SET mode

Mic [DWN]

(in VFO mode) during Menu

mode when the mic key paddle

 

 

operation is ON.

 

 

[A/B]

 

 

 

[M/V]

 

 

 

[SPLIT]

 

 

 

53

Image 61
Contents Notification TS-590SPage $7856 +$1.28127,&727+865 2567$57,11*&21917,2162//2 Accessory Comment Quantity Type6833/,$&&6625,6 Instruction Action35&$87,216 217176 217176 Memory FeaturesData Communications Rejecting InterferenceTroubleshooting Installing OptionsOptional Accessories Specifications$1711$&211&7,21 167$//$7,215281&211&7,21 +71,1*3527&7,21$&&6625&211&7,216 87,/,=,1*7+%$53/$&,1*866 GND Stby MIC GND MIC PTT Down 77,1*$&48$,17 KEY Delay52173$1 Meter DRV*77,1*$&48$,17 CH2 REC CH1 RECCH3 REC RX/4 RECAbcd ,63/$*77,1*$&48$,17 523+21 $53$1+,1*325212 235$7,1*%$6,&6$-867,1*7+92/80 1*92$2592%1*$02 1*$%$1235$7,1*%$6,&6 Gene08/7,81&7,21075 $-867,1*7+648/&+781,1*$5481 Meter Name Parameters Measured1*75$160,66,21325 75$160,77,1523+21*$,1 Press PWR TX Moni+$7,6$018 0186783018$018% 018$&&660186783 018&21,*85$7,21AM MULTI/CH Control ON/ OFF Auto Mode OperationFM MULTI/CH Control Number of Quick Memory ChannelsTIME-OUT Timer CW WeightingCW Rise Time BUG KEY FunctionTX Inhibit Constant RecordingCOM Port Baudrate USB Port BaudratePower on Message Auto Power OFFUSB VOX Gain ACC2 VOX GainAvailable alphanumeric characters +$5$&7517566%75$160,66,21 $6,&&20081,&$7,21675$160,66,21 $552%$1,7+250 $075$160,66,21%$6,&&20081,&$7,216 32521066$ $55,5/9%$6,&&20081,&$7,216 $872=52%$7 6,72153,7&+548163/,75481&235$7,21 +$1&&20081,&$7,21667 75$160,66,215481&67 1+$1&&20081,&$7,216 53$75235$7,2175$160,77,1*$721 7215481&,6&$1 &7&66235$7,21 6HOHFWLQJD7RQHUHTXHQF\ Press AGC/T SEL665481&,6&$1 526672137,21 20081,&$7,1*$,61*2855481  LUHFWUHTXHQF\QWU\ 5&,9,1&5017$/781,1* &20081,&$7,1*$,6$*& $8720$7,&*$,1&21752/ 92 92,&235$775$160,66,21 75$160,66,21 0LFURSKRQH,QSXW/HYHO  HOD\7LPH63&+352&6625 Press M.IN/ Scan SG.SEL to set your desired delay time 75$160,7,1&5017$/781,1*  6SHHFK3URFHVVRUIIHFW86/2&.287 75$160,7,1+,%,7+$1*,1*5481&+,/75$160,77,1  UHTXHQF\5HVSRQVH&XUYHV7521,&.5 %5$.,186,1*60,%5$.,1258//%5$.,1 7521,&.502$872,*+7,1 &20081,&$7,1*$,6 7,02066$*0025 .81&7,21 7UDQVPLWWLQJ&0HVVDJHV 5481&&255&7,2125 &KDQJLQJWKH&6LGHWRQH9ROXPH  ,QVHUW.H\LQJ831.3$/02 &20081,&$7,1*$,6 $872&7,166%02$327$1$6+3$/326,7,216 $,27/73 577 $7$&20081,&$7,216+$66+,7.,1*%$8 36. A./ Canada Iaru Region Europe/ Africa63,/756 1*,17551+$1*,1*7+63,/75%$1,7+  DWD0RGH$872127&+,/75 66% 5-&7,1*,17551$18$/127&+,/75 66%&6. $7&$1&/ 66%$0 35$03/,,5 12,6%/$1.5$7718$725 5956 5&37,21 0025&+$11/6 0025$78566725,1*$7$,10025  6LPSOH&KDQQHOV002575$165 0025$7856 00255&$//$16&52 0HPRU\5HFDOO  0HPRU\6FUROO6725,1*5481&5$1*6 0025$78560025&+$11//2&.287 48,&.0025$6,1*0025&+$11/6 0025&+$11/1$06725,1*,17248,&.0025 0025$7856 180%5248,&.0025&+$11/6$//,1*48,&.0025&+$11/6 70325$55481&&+$1*6926&$1 1250$/6&$1352*5$06&$1 Press and hold Scan SG.SEL352*5$06&$13$57,$//6/2 6&$16&$1 $1+2 00256&$1$15680 $//&+$11/6&$16&$1 52836&$1 48,&.00256&$1 0HPRU\*URXS  6FDQ*URXS6HOHFW$1711$6 235$725&2191,1&6$32 $XWR3RZHU2 $8720$7,&$1711$7815$87202 Internal Antenna Tuner Preset Frequency Range MHz235$725&2191,1&6 35677,181&7,21 Mode Morse Code OutputBeep Type Meaning $5$03/,,5&21752 63/$81&7,216 75$16&,9552173$1 352*5$00$%/81&7,21.6523+21.6 2877,05 63548$/,=575$169575 325 021,725781 48,&.$7$75$165235$725&2191,1&6 86,1*48,&.75$165 203875&2175220081,&$7,213$5$0756  7UDQVIHUULQJDWD+$1*,1*7+6,*1$/257+&20750,1$ 235$725&2191,1&6 751$/$8,2677,1*621752//,1*7+766520$3  $XGLR/HYHO6HWWLQJV066$*3/$%$ 235$725&2191,1&6 25,1*066$*6 &KHFNLQJ0HVVDJHV  6HQGLQJ0HVVDJHV2167$175&25,1 Operations using VOICE1 Announcement92,&*8  &KDQJLQJ0HVVDJH3OD\EDFN9ROXPHSET FSK REV/ FM/AM 9RLFH*XLGH$QQRXQFHPHQW9ROXPH 05*1&&$// .7321/  9RLFH*XLGH$QQRXQFHPHQW6SHHG  9RLFH*XLGH$QQRXQFHPHQW/DQJXDJH3$&.7&/8675781 5266%$153$75235$7,21 &200$1,,,$*5$0 &200$1353$5$7,21 6WDUWLQJ6N\&RPPDQG,,RSHUDWLRQ750,1$/6&5,37,216 211&7,1*35,3+5$/48,301720&211&725 $&&&211&725&211&725 $7&211&725 IRU$7 203$7,%/75$16&,95 203875&211&7,1*35,3+5$/48,3017 +0+/,1$5$03/,,5 577235$7,2171&$10&3 $1711$78155266%$153$75 5029,1*7+%27720&$6 167$//,1*237,21692,&*8, 6725$*81,7 551&5481&&$/,%5$7,21 627&2,167$//,1*237,216 TS-590S transceiver without SO-335&$87,216 02%,/%5$&.715$/,1250$7,21 7528%/6+227,1659 659,&1277528%/6+227,1 Problem Probable Cause Corrective Action7528%/6+227,1 Followed7528%/6+227,1 MCP $/677,1*6 52352&662556792567 5673256833 235$7,21127,&61751$/&22/,1*$1 1751$/%$76VGS-1 237,21$/$&&6625,663&,,&$7,216 SSB/ CW/ FSK/ AM 63&,,&$7,216 TransmitterCW/ FSK $XGLRRXWSXW ŸGLVWRUWLRQ