Graco 249881, 246008 Meter Operation, Asleep / Awake Mode, High/Low Flow Rate Indicator

Page 10

Meter Operation

Meter Operation

Asleep / Awake Mode

Asleep is a battery-saving mode in which the display goes blank after two minutes of inactivity during normal operation. The display comes Awake from sleep mode when any button is pressed.

High/Low Flow Rate Indicator

The electronic meter dispenses fluids at two different rates.

As the trigger is partially engaged, the flow rate is low and is indicated by two bars on the display. See FIG. 9.

FIG. 9

When the trigger is fully engaged, the flow rate is high and is indicated by four bars on the display. See FIG. 10.

Battery Life Indicator

On the right side of the display is a series of four bars located under the word BATT. See FIG. 11. The pres- ence of all four bars indicates a fully charged battery.

The bars decline in number as the meter is used and the battery discharges. All Matrix meter batteries should be re-charged at the end of the working day to assure good performance the next work day.

Batteries can be recharged at anytime without battery damage.

At one bar on the display you will have about 20-40% of the charge remaining.

If a meter is removed from service for an extended time the battery should be removed and recharged.

If you see the message “Remove Low Battery - Wait 30 Seconds Then Replace”, remove the battery, wait 30 seconds, and then replace it with a charged battery.

Even when a meter is idle (asleep), the meter is still functioning and the battery will be used.

FIG. 11

FIG. 10

10

309497L

Image 10
Contents Matrix Meter Contents Manual ConventionsSkin Injection Hazard Programming the Meter Meter ProgrammingProgramming the Meter Meter Installation DESCRIPTION, See F IGMounting Brackets DESCRIPTION, See FIGPre-installation Procedure Pressure Relief ProcedureGrounding Meter Installation to Hose Installing Nozzle ExtensionPressurizing the System Battery Life Indicator Asleep / Awake ModeHigh/Low Flow Rate Indicator Meter OperationSystem Monitoring Parts Room AuthorizationSecurity Modes PIN CodeAssigning Work Orders and Job Numbers at the Meter Work Orders and Job NumbersAssigning Work Orders and Job Numbers from the PC 32567 IC9 2AC03 458A1 2233APlacing a Meter in the Emergency Mode Emergency Mode1222 Manual Dispense Mode Preset Dispense ModeDispense Options Quick-LockNozzle Restricted Preset Dispense ModeRemoving and Replacing the Battery Nozzle opens and closes with Less than one turnFications TroubleshootingProblem Cause Solution Flow. Warning do not exceed the maximum workingPressure of the meter 1500 psi 103 bar. If flushing Problem Cause Solution Metric Measurement Calculating the Calibration FactorMeasurement 309497L Follow the Pressure Relief Procedure, page 8, whenever you ServiceReplacing or Cleaning Filter Replacing Quick-lockNozzleReplacing the Bezel Service Replacing the Trigger Relieve the Pressure Ti4323 Service Replacing the Meter Electronics Service Service Service Parts Drawing for the 246008 and 249881 Electronic Meters Parts List for the 246008 and 249881 Electronic Meters Description QtyQty Nozzle Extension AccessoriesKit DescriptionTechnical Specifications 309497L Dimensions Graco Standard Warranty Graco Phone Numbers