Graco instruction manual Parts Drawing for the 246008 and 249881 Electronic Meters

Page 32

Parts Drawing for the 246008 and 249881 Electronic Meters

Parts Drawing for the 246008 and 249881 Electronic Meters

 

31†

 

 

 

3†

23 †6

40

 

37

7

 

 

 

13

 

22 †

36 †

41†

8

 

14 †

 

 

4†

18†

 

44†

123 4

43†meter housing

(not available for sale)

5 8 42

19†

1torque to 20 - 25 ft. lbs

2apply thread sealant when reassembling

3torque to 7 - 10 in. lbs

4remove screws with a T-10 torx driver

5remove screws with a Phillips screw driver

29

1

2

24

11

9 6

ti4307

6plunger must be inserted fully shouldered against the end of the spring.

7spring must be inserted firmly into trigger with a clockwise screwing motion. When fully assembled

plunger should sit level with the underside surface of the trigger.

8torque to 3 - 4 in. lbs

32

309497L

Image 32
Contents Matrix Meter Contents Manual ConventionsSkin Injection Hazard Programming the Meter Meter ProgrammingProgramming the Meter Meter Installation DESCRIPTION, See F IGMounting Brackets DESCRIPTION, See FIGGrounding Pressure Relief ProcedurePre-installation Procedure Pressurizing the System Installing Nozzle ExtensionMeter Installation to Hose Asleep / Awake Mode High/Low Flow Rate IndicatorBattery Life Indicator Meter OperationParts Room Authorization Security ModesSystem Monitoring PIN CodeWork Orders and Job Numbers Assigning Work Orders and Job Numbers from the PCAssigning Work Orders and Job Numbers at the Meter 32567 IC9 2AC03 458A1 2233A1222 Emergency ModePlacing a Meter in the Emergency Mode Dispense Options Preset Dispense ModeManual Dispense Mode Restricted Preset Dispense Mode Removing and Replacing the BatteryQuick-LockNozzle Nozzle opens and closes with Less than one turnTroubleshooting Problem Cause SolutionFications Flow. Warning do not exceed the maximum workingPressure of the meter 1500 psi 103 bar. If flushing Problem Cause Solution Measurement Calculating the Calibration FactorMetric Measurement 309497L Service Replacing or Cleaning FilterFollow the Pressure Relief Procedure, page 8, whenever you Replacing Quick-lockNozzleReplacing the Bezel Service Replacing the Trigger Relieve the Pressure Ti4323 Service Replacing the Meter Electronics Service Service Service Parts Drawing for the 246008 and 249881 Electronic Meters Parts List for the 246008 and 249881 Electronic Meters Description QtyNozzle Extension Accessories KitQty DescriptionTechnical Specifications 309497L Dimensions Graco Standard Warranty Graco Phone Numbers