Make sure that the trigger plunger (23) is centered with the circular trigger switch. Also ensure that the trig- ger spring (37) is slid fully into position. Make sure that all other meter parts are positioned securely and in the correct location. See FIG. 50.

37 23

FIG. 50

20.Replace the bezel (31) onto the right meter cover half (18).

Service

21.Assemble the covers (18 & 19). Insert several of the screws (12) to hold the cover halves (18 & 19) together. Test the display and trigger by inserting a battery (11) and powering on the unit. It may take a minute or so before the display starts.

22.If the display appears test the trigger to be sure that both dispense settings work correctly. If the display does not appear or the trigger does not function:

make sure that a charged battery (11) is being used.

check that the connections from the new bezel (31) to the circuit board (41) are fastened cor- rectly and securely.

check that all parts are repositioned securely and in the correct location.

check that the trigger connection to the RF board (3) is fastened correctly and securely.

check that the trigger switch is centered prop- erly and that no gaps have formed between the switch and circular indent.

23.Replace the remaining screws (12) and (42) that hold the cover halves together. Torque all screws to 7 - 10 in. lbs.

309497L

31

Image 31
Contents Matrix Meter Manual Conventions ContentsSkin Injection Hazard Meter Programming Programming the MeterProgramming the Meter DESCRIPTION, See F IG Meter InstallationDESCRIPTION, See FIG Mounting BracketsPre-installation Procedure Pressure Relief ProcedureGrounding Meter Installation to Hose Installing Nozzle ExtensionPressurizing the System Meter Operation Asleep / Awake ModeHigh/Low Flow Rate Indicator Battery Life IndicatorPIN Code Parts Room AuthorizationSecurity Modes System Monitoring32567 IC9 2AC03 458A1 2233A Work Orders and Job NumbersAssigning Work Orders and Job Numbers from the PC Assigning Work Orders and Job Numbers at the MeterPlacing a Meter in the Emergency Mode Emergency Mode1222 Manual Dispense Mode Preset Dispense ModeDispense Options Nozzle opens and closes with Less than one turn Restricted Preset Dispense ModeRemoving and Replacing the Battery Quick-LockNozzleFlow. Warning do not exceed the maximum working TroubleshootingProblem Cause Solution FicationsPressure of the meter 1500 psi 103 bar. If flushing Problem Cause Solution Metric Measurement Calculating the Calibration FactorMeasurement 309497L Replacing Quick-lockNozzle ServiceReplacing or Cleaning Filter Follow the Pressure Relief Procedure, page 8, whenever youReplacing the Bezel Service Replacing the Trigger Relieve the Pressure Ti4323 Service Replacing the Meter Electronics Service Service Service Parts Drawing for the 246008 and 249881 Electronic Meters Description Qty Parts List for the 246008 and 249881 Electronic MetersDescription Nozzle Extension AccessoriesKit QtyTechnical Specifications 309497L Dimensions Graco Phone Numbers Graco Standard Warranty