Make sure that the trigger plunger (23) is centered with the circular trigger switch. Also ensure that the trig- ger spring (37) is slid fully into position. Make sure that all other meter parts are positioned securely and in the correct location. See FIG. 50.
37 23
FIG. 50
20.Replace the bezel (31) onto the right meter cover half (18).
Service
21.Assemble the covers (18 & 19). Insert several of the screws (12) to hold the cover halves (18 & 19) together. Test the display and trigger by inserting a battery (11) and powering on the unit. It may take a minute or so before the display starts.
22.If the display appears test the trigger to be sure that both dispense settings work correctly. If the display does not appear or the trigger does not function:
•make sure that a charged battery (11) is being used.
•check that the connections from the new bezel (31) to the circuit board (41) are fastened cor- rectly and securely.
•check that all parts are repositioned securely and in the correct location.
•check that the trigger connection to the RF board (3) is fastened correctly and securely.
•check that the trigger switch is centered prop- erly and that no gaps have formed between the switch and circular indent.
23.Replace the remaining screws (12) and (42) that hold the cover halves together. Torque all screws to 7 - 10 in. lbs.
309497L | 31 |