Graco Parts List for the 246008 and 249881 Electronic Meters, Description Qty

Page 33

Parts List for the 246008 and 249881 Electronic Meters

Parts List for the 246008 and 249881 Electronic Meters

Ref.

 

 

 

No.

Part No.

Description

Qty.

3†

 

MODULE, control, elec

1

4†

 

SWITCH, PSM, two position

1

6

109018

PACKING, o-ring

1

9

114017

FILTER, 80 mesh

1

11

117310

BATTERY, 9.6V NMH rechargable 1

12†★✓

 

SCREW, mach, torx, 5-20x1/2

11

13†

 

SPRING, plunger

1

14†

 

SPRING, return

1

18†

 

COVER, valve right

1

19†

 

COVER, valve left

1

22†

 

TRIGGER

1

23†

 

PLUNGER, trigger

1

Ref.

 

 

 

No.

Part No.

Description

Qty.

24

15D587

BOOT, rear

1

29

240416

SWIVEL, straight

1

31†

 

BEZEL

1

36†

 

PLUNGER, inside trigger

1

37†

 

SPRING, inside plunger

1

40†★✓15D618

GUARD, impact

1

41†

 

SCREW, mach, HD, cross

3

42†★✓

 

SCREW, phillips

4

43†

 

RING, quad

1

44†

 

WASHER

3

A grounding strap part no. 112190 is included with each of the following kits.

CAUTION

Static electricity can damage the electronic compo- nents within the meter if the grounding wrist strap pro- vided is not used during repair kit service.

Included in Bezel Repair Kit 246438.

Included in Trigger Repair Kit 246439 for meter 246008 or kit 249883 for meter 249881.

Included in Electronics Repair Kit 246675 for meter 246008 or kit 249882 for meter 249881.

309497L

33

Image 33
Contents Matrix Meter Manual Conventions ContentsSkin Injection Hazard Meter Programming Programming the MeterProgramming the Meter DESCRIPTION, See F IG Meter InstallationDESCRIPTION, See FIG Mounting BracketsPressure Relief Procedure Pre-installation ProcedureGrounding Installing Nozzle Extension Meter Installation to HosePressurizing the System High/Low Flow Rate Indicator Asleep / Awake ModeBattery Life Indicator Meter OperationSecurity Modes Parts Room AuthorizationSystem Monitoring PIN CodeAssigning Work Orders and Job Numbers from the PC Work Orders and Job NumbersAssigning Work Orders and Job Numbers at the Meter 32567 IC9 2AC03 458A1 2233AEmergency Mode Placing a Meter in the Emergency Mode1222 Preset Dispense Mode Manual Dispense ModeDispense Options Removing and Replacing the Battery Restricted Preset Dispense ModeQuick-LockNozzle Nozzle opens and closes with Less than one turnProblem Cause Solution TroubleshootingFications Flow. Warning do not exceed the maximum workingPressure of the meter 1500 psi 103 bar. If flushing Problem Cause Solution Calculating the Calibration Factor Metric MeasurementMeasurement 309497L Replacing or Cleaning Filter ServiceFollow the Pressure Relief Procedure, page 8, whenever you Replacing Quick-lockNozzleReplacing the Bezel Service Replacing the Trigger Relieve the Pressure Ti4323 Service Replacing the Meter Electronics Service Service Service Parts Drawing for the 246008 and 249881 Electronic Meters Description Qty Parts List for the 246008 and 249881 Electronic MetersKit Nozzle Extension AccessoriesQty DescriptionTechnical Specifications 309497L Dimensions Graco Phone Numbers Graco Standard Warranty