Graco 249881, 246008 Dispense Options, Preset Dispense Mode, Manual Dispense Mode

Page 14

Meter Operation

Dispense Options

The meter dispense options are determined by the sys- tem administrator at the time the meter is programmed. Meter dispense options include:

Manual Dispense Mode

Preset Dispense Mode

Restricted Preset Dispense Mode

To change the meter from one mode to another, you must reprogram the meter. See Programming the Meter on page 4.

Preset Dispense Mode

Meters programmed in preset mode count down from a specified value to zero and shut off automatically. The preset value can be increased or decreased from the ini- tial value using the up and down keypad buttons.

1.If necessary, enter the PIN code, Parts Room Authorization request and/or work order request.

2.Press ACTIVATE to enter the dispense mode. The preset default amount entered into the PC will appear on the meter. See FIG. 17.

Manual Dispense Mode

To dispense fluids in this mode:

1.If necessary, enter the PIN code, Parts Room Authorization request and/or the Work Order request.

2.Press the left or right keypad button under ACTI- VATE to begin communication with the PC. Both ACTIVATE words on the display screen will change to END.

3.Pull the meter trigger to dispense. The meter counts up to the desired amount.

4.Release the trigger when the desired amount is obtained. Then press the right or left keypad button to end the dispense. This logs the dispense amount to the PC and returns the meter to its programmed entry screen.

If END is not pressed, after five minutes the meter will automatically end the job and log the dispense to the PC.

Once the preset amount is dispensed, the meter display automatically changes to read TOP OFF MODE. This allows the operator to add additional fluid after the pre- set amount is dispensed. The Top Off amount to be dis- pensed can be limited during meter programming. See FIG. 18.

FIG. 17

3.If desired press the arrow up or arrow down keypad button to change the preset amount.

OR

4.Press the right keypad button under the word CLEAR to zero out the preset amount. The arrow up and arrow down keypad buttons are used to enter a new amount of fluid to dispense.

5.Pull and release the meter trigger to start the dis- pense. The meter dispenses the preset amount and shuts off.

Flow can be stopped at any time during the dispense by pressing the meter trigger or any button on the meter display.

An appropriate preset amount can be set for each work order when entering work orders at the PC.

14

309497L

Image 14
Contents Matrix Meter Contents Manual ConventionsSkin Injection Hazard Programming the Meter Meter ProgrammingProgramming the Meter Meter Installation DESCRIPTION, See F IGMounting Brackets DESCRIPTION, See FIGGrounding Pressure Relief ProcedurePre-installation Procedure Pressurizing the System Installing Nozzle ExtensionMeter Installation to Hose Battery Life Indicator Asleep / Awake ModeHigh/Low Flow Rate Indicator Meter OperationSystem Monitoring Parts Room AuthorizationSecurity Modes PIN CodeAssigning Work Orders and Job Numbers at the Meter Work Orders and Job NumbersAssigning Work Orders and Job Numbers from the PC 32567 IC9 2AC03 458A1 2233A1222 Emergency ModePlacing a Meter in the Emergency Mode Dispense Options Preset Dispense ModeManual Dispense Mode Quick-LockNozzle Restricted Preset Dispense ModeRemoving and Replacing the Battery Nozzle opens and closes with Less than one turnFications TroubleshootingProblem Cause Solution Flow. Warning do not exceed the maximum workingPressure of the meter 1500 psi 103 bar. If flushing Problem Cause Solution Measurement Calculating the Calibration FactorMetric Measurement 309497L Follow the Pressure Relief Procedure, page 8, whenever you ServiceReplacing or Cleaning Filter Replacing Quick-lockNozzleReplacing the Bezel Service Replacing the Trigger Relieve the Pressure Ti4323 Service Replacing the Meter Electronics Service Service Service Parts Drawing for the 246008 and 249881 Electronic Meters Parts List for the 246008 and 249881 Electronic Meters Description QtyQty Nozzle Extension AccessoriesKit DescriptionTechnical Specifications 309497L Dimensions Graco Standard Warranty Graco Phone Numbers