Graco 246008, 249881 Security Modes, System Monitoring, PIN Code, 2122, Parts Room Authorization

Page 11

Security Modes

When the meters were originally programmed by the system administrator, one of the following security choices was entered:

System Monitoring

PIN Code

Parts Room Authorization

Prior to dispensing, it may be necessary to complete one of the following security procedures, depending on the security mode selected.

System Monitoring

When set for system monitoring, no security authoriza- tion is required by the operator. However, any amount of fluid dispensed is automatically sent by the meter to the PC where it is recorded for future reference.

PIN Code

PIN Code (personal identification number) means that a four digit PIN code must be entered at the meter to obtain dispense authorization. To use a meter with PIN code security:

1.Use the up and down arrow keypad buttons to select the first number of the PIN code.

2.Press the right keypad button to move the cursor to the next position.

3.Use the up and down keypad buttons to select the desired number. Continue this process until the PIN code number is completed. See FIG. 12.

Meter Operation

PIN CODE

ENTER

2122

LEFTRIGHT

FIG. 12

4.When the pin code is complete, press the right key- pad button until the cursor underlines the Enter option. Press the up arrow on the meter keypad. This action will enter the PIN code and send it to the PC.

5.The PC recognizes the PIN code and authorizes the meter to dispense.

Parts Room Authorization

This mode provides high level security and requires a Parts Room Administrator to authorize each dispense.

AUTHORIZATION

REQUIRED

REQUESTREQUEST

APPROVALAPPROVAL

FIG. 13

1.Press either the left keypad or right keypad button under REQUEST APPROVAL. This sends the request to the parts room administrator’s PC for dis- pense authorization. See FIG. 13.

2.The administrator grants authorization at the PC, which then authorizes the meter to dispense.

309497L

11

Image 11
Contents Matrix Meter Manual Conventions ContentsSkin Injection Hazard Meter Programming Programming the MeterProgramming the Meter DESCRIPTION, See F IG Meter InstallationDESCRIPTION, See FIG Mounting BracketsGrounding Pressure Relief ProcedurePre-installation Procedure Pressurizing the System Installing Nozzle ExtensionMeter Installation to Hose Meter Operation Asleep / Awake ModeHigh/Low Flow Rate Indicator Battery Life IndicatorPIN Code Parts Room AuthorizationSecurity Modes System Monitoring32567 IC9 2AC03 458A1 2233A Work Orders and Job NumbersAssigning Work Orders and Job Numbers from the PC Assigning Work Orders and Job Numbers at the Meter1222 Emergency ModePlacing a Meter in the Emergency Mode Dispense Options Preset Dispense ModeManual Dispense Mode Nozzle opens and closes with Less than one turn Restricted Preset Dispense ModeRemoving and Replacing the Battery Quick-LockNozzleFlow. Warning do not exceed the maximum working TroubleshootingProblem Cause Solution FicationsPressure of the meter 1500 psi 103 bar. If flushing Problem Cause Solution Measurement Calculating the Calibration FactorMetric Measurement 309497L Replacing Quick-lockNozzle ServiceReplacing or Cleaning Filter Follow the Pressure Relief Procedure, page 8, whenever youReplacing the Bezel Service Replacing the Trigger Relieve the Pressure Ti4323 Service Replacing the Meter Electronics Service Service Service Parts Drawing for the 246008 and 249881 Electronic Meters Description Qty Parts List for the 246008 and 249881 Electronic MetersDescription Nozzle Extension AccessoriesKit QtyTechnical Specifications 309497L Dimensions Graco Phone Numbers Graco Standard Warranty