Service

D

F

F

E

E

FIG. 34

14.Insert the RF Board (103) into the new right meter half (18). See FIG. 35.

Ensure that the RF Board (103) is positioned securely in the slots (A) of the new right meter half (18). See FIG. 35.

101 A

103

FIG. 35

15.Slide the trigger assembly (13, 14, 22, 23, 36, & 37) back onto the mounting peg on the right half of the meter (18). See FIG. 36.

Ensure that the circular trigger plunger (23) is cen- tered with the trigger switch. Also ensure that the trigger spring (37) is securely slid into position. See FIG. 36.

37 23

ti4323

FIG. 36

16.Make sure that all other meter parts are positioned securely and in the correct location. See FIG. 37.

FIG. 37

17. Attach the bezel (31) to the right meter housing (18).

Ensure that all meter parts are positioned securely and in the correct location. Ensure that all cables are routed correctly throughout the meter and will not be pinched or kinked when the halves are reas- sembled See FIG. 38 and FIG. 39.

26

309497L

Image 26
Contents Matrix Meter Contents Manual ConventionsSkin Injection Hazard Programming the Meter Meter ProgrammingProgramming the Meter Meter Installation DESCRIPTION, See F IGMounting Brackets DESCRIPTION, See FIGGrounding Pressure Relief ProcedurePre-installation Procedure Pressurizing the System Installing Nozzle ExtensionMeter Installation to Hose Battery Life Indicator Asleep / Awake ModeHigh/Low Flow Rate Indicator Meter OperationSystem Monitoring Parts Room AuthorizationSecurity Modes PIN CodeAssigning Work Orders and Job Numbers at the Meter Work Orders and Job NumbersAssigning Work Orders and Job Numbers from the PC 32567 IC9 2AC03 458A1 2233A1222 Emergency ModePlacing a Meter in the Emergency Mode Dispense Options Preset Dispense ModeManual Dispense Mode Quick-LockNozzle Restricted Preset Dispense ModeRemoving and Replacing the Battery Nozzle opens and closes with Less than one turnFications TroubleshootingProblem Cause Solution Flow. Warning do not exceed the maximum workingPressure of the meter 1500 psi 103 bar. If flushing Problem Cause Solution Measurement Calculating the Calibration FactorMetric Measurement 309497L Follow the Pressure Relief Procedure, page 8, whenever you ServiceReplacing or Cleaning Filter Replacing Quick-lockNozzleReplacing the Bezel Service Replacing the Trigger Relieve the Pressure Ti4323 Service Replacing the Meter Electronics Service Service Service Parts Drawing for the 246008 and 249881 Electronic Meters Parts List for the 246008 and 249881 Electronic Meters Description QtyQty Nozzle Extension AccessoriesKit DescriptionTechnical Specifications 309497L Dimensions Graco Standard Warranty Graco Phone Numbers