Graco 249881, 246008 instruction manual Problem Cause Solution

Page 18

Troubleshooting

Problem

Cause

Solution

 

 

 

Meter has been in

E-Prom on meter board has reached

Attempt to reprogram the meter. If you see a pop-up

service for an

the end of its life.

screen on the PC that says, “Memory Failure” and/or the

extended period of

 

meter screen defaults to the ACTIVATE/ACTIVATE

time and begins to

 

screen, the E-Prom on the meter board must be

work erratically

 

changed. Install the Electronics Repair Kit (246675).

such as loss of

 

The Electronics Repair Kit includes a new meter board

Work Orders or

 

with E-Prom. The meter then can be reprogrammed to

Security settings.

 

the features desired.

 

 

 

Meter leaks.

Extension may be loose from meter

Tighten seal nut using two wrenches.

 

fluid housing.

 

 

 

 

 

Swivel connection at hose may be

Clean, seal, and tighten joint.

 

leaking.

 

 

 

 

Meter cuts on and

The trigger is being held during pre-

Release the trigger during preset dispense.

off during preset

set dispense.

 

dispense.

 

 

Trigger or trigger membrane switch is

Replace the trigger and trigger membrane using the

 

 

damaged - flow bars DO show on the

Trigger Repair Kit (246439 N. A., 249883 Australia). See

 

meter display when the trigger IS

page 33. Do not use clamps or wire ties to hold trigger

 

NOT actuated.

during dispense, doing so voids the warranty.

 

 

 

Meter displays

Trigger or trigger membrane switch is

Replace the trigger and trigger membrane using the

“active trig”

damaged - flow bars DO show on the

Trigger Repair Kit (246439). See page 33. Do not use

 

meter display when the trigger IS

clamps or wire ties to hold trigger during dispense, doing

 

NOT actuated.

so voids the warranty.

 

 

 

 

Trigger is being held before activating

Release trigger to activate meter.

 

meter for dispense.

 

 

 

 

* To use the Matrix Emergency Mode contact the Matrix System Administrator in your facility.

18

309497L

Image 18
Contents Matrix Meter Contents Manual ConventionsSkin Injection Hazard Programming the Meter Meter ProgrammingProgramming the Meter Meter Installation DESCRIPTION, See F IGMounting Brackets DESCRIPTION, See FIGPressure Relief Procedure Pre-installation ProcedureGrounding Installing Nozzle Extension Meter Installation to HosePressurizing the System Battery Life Indicator Asleep / Awake ModeHigh/Low Flow Rate Indicator Meter OperationSystem Monitoring Parts Room AuthorizationSecurity Modes PIN CodeAssigning Work Orders and Job Numbers at the Meter Work Orders and Job NumbersAssigning Work Orders and Job Numbers from the PC 32567 IC9 2AC03 458A1 2233AEmergency Mode Placing a Meter in the Emergency Mode1222 Preset Dispense Mode Manual Dispense ModeDispense Options Quick-LockNozzle Restricted Preset Dispense ModeRemoving and Replacing the Battery Nozzle opens and closes with Less than one turnFications TroubleshootingProblem Cause Solution Flow. Warning do not exceed the maximum workingPressure of the meter 1500 psi 103 bar. If flushing Problem Cause Solution Calculating the Calibration Factor Metric MeasurementMeasurement 309497L Follow the Pressure Relief Procedure, page 8, whenever you ServiceReplacing or Cleaning Filter Replacing Quick-lockNozzleReplacing the Bezel Service Replacing the Trigger Relieve the Pressure Ti4323 Service Replacing the Meter Electronics Service Service Service Parts Drawing for the 246008 and 249881 Electronic Meters Parts List for the 246008 and 249881 Electronic Meters Description QtyQty Nozzle Extension AccessoriesKit DescriptionTechnical Specifications 309497L Dimensions Graco Standard Warranty Graco Phone Numbers