| Technical Specifications |
Technical Specifications |
|
|
|
Maximum Fluid Working Pressure | 1500 psi (10.3 MPa, 103 bar) |
|
|
Operating pressure range (* ◆) | 100 to 1500 psi (0.7 to 10.3 MPa) (7 bar to 103 bar) |
|
|
Maximum Dynamic Working Pressure | 600 psi (4.1 MPa, 41.4 bar) |
(while dispensing) (★) |
|
|
|
Flow Range | 0.26 to 5 gpm (1 to 18.9 lpm) |
|
|
Weight (with battery and rigid nozzle extension | 4.5 lb (2.0 kg) |
|
|
Units of measurement | user selectable, pints, quarts, gallons or liters |
|
|
Maximum recorded dispense volume | 999.00 units |
|
|
Maximum preset volume | 900.0 |
|
|
Inlet size | 1/2” npt(f) |
|
|
Outlet size | 3/8” npt(f) |
|
|
Operating temperature range | 32° F to 120° F (0° C to 49° C) |
|
|
Storage temperature range | |
|
|
Battery | rechargeable |
|
|
Battery Warranty | 6 months |
|
|
Battery storage temperature range | 50° F to 86° F (10° C to 30° C) |
|
|
Wetted parts | zinc, stainless steel, carbon steel, polyurethane, nitrile rubber |
|
|
Fluid compatibility | lubricating oils, antifreeze mixtures |
|
|
Accuracy (†) | +/- 0.5 percent |
|
|
Repeatability (‡) | +/- 0.15 percent |
|
|
RF Communication | |
| |
|
|
Unobstructed RF Communication Range (based on | |
building construction and RF environment) |
|
|
|
Obstructed RF Communication Range (based on | |
building construction and RF environment) |
|
|
|
Approvals (for RF device contained in meter | FCC, Industry Canada (IC) |
246008) |
|
|
|
Conformity (for RF device contained in meter | ACMA (Australia) |
249881) |
|
|
|
*Minimum pressure loss at 1.5 gpm (5.7 lpm) with
†At 2.5 gpm (9.5 lpm), at 70° F (21° C) with
‡ At 2.5 gpm (9.5 lpm), at 70° F (21° C) with
◆Specification based on 30W oil. Lighter viscosity fluid (i.e.,
★Using 30W oil at 70°F (21°C). Maximum pressure will be slightly lower with higher viscosity fluids (i.e., gear oil). A lower ratio pump may be required to reduce system pressure and maintain sufficient flow.
309497L | 35 |