Graco 246008, 249881 instruction manual Technical Specifications

Page 35

 

Technical Specifications

Technical Specifications

 

 

 

Maximum Fluid Working Pressure

1500 psi (10.3 MPa, 103 bar)

 

 

Operating pressure range (* )

100 to 1500 psi (0.7 to 10.3 MPa) (7 bar to 103 bar)

 

 

Maximum Dynamic Working Pressure

600 psi (4.1 MPa, 41.4 bar)

(while dispensing) ()

 

 

 

Flow Range

0.26 to 5 gpm (1 to 18.9 lpm)

 

 

Weight (with battery and rigid nozzle extension

4.5 lb (2.0 kg)

 

 

Units of measurement

user selectable, pints, quarts, gallons or liters

 

 

Maximum recorded dispense volume

999.00 units

 

 

Maximum preset volume

900.0

 

 

Inlet size

1/2” npt(f)

 

 

Outlet size

3/8” npt(f)

 

 

Operating temperature range

32° F to 120° F (0° C to 49° C)

 

 

Storage temperature range

-30° F to 120° F (-34° C to 49° C)

 

 

Battery

rechargeable nickel-metal hydride 9.6 VDC

 

 

Battery Warranty

6 months

 

 

Battery storage temperature range

50° F to 86° F (10° C to 30° C)

 

 

Wetted parts

zinc, stainless steel, carbon steel, polyurethane, nitrile rubber

 

 

Fluid compatibility

lubricating oils, antifreeze mixtures

 

 

Accuracy (†)

+/- 0.5 percent

 

 

Repeatability (‡)

+/- 0.15 percent

 

 

RF Communication

902-928 MHz frequency hopping, spread-spectrum - N. A.

 

915-928 MHz frequency hopping, spread-spectrum - Australia

 

 

Unobstructed RF Communication Range (based on

300-500 ft. (91.0-152.0 m)

building construction and RF environment)

 

 

 

Obstructed RF Communication Range (based on

250-300 ft. (76.2-91.0 m)

building construction and RF environment)

 

 

 

Approvals (for RF device contained in meter

FCC, Industry Canada (IC)

246008)

 

 

 

Conformity (for RF device contained in meter

ACMA (Australia)

249881)

 

 

 

*Minimum pressure loss at 1.5 gpm (5.7 lpm) with 30-weight oil at 70° F (21° C) is 70 psi.

At 2.5 gpm (9.5 lpm), at 70° F (21° C) with 10-weight oil, and 1 gallon dispensed. May require calibration.

‡ At 2.5 gpm (9.5 lpm), at 70° F (21° C) with 10-weight oil, and 1 gallon dispensed.

Specification based on 30W oil. Lighter viscosity fluid (i.e., anti-freeze) will require a slightly higher inlet fluid pressure to open the Matrix valve.

Using 30W oil at 70°F (21°C). Maximum pressure will be slightly lower with higher viscosity fluids (i.e., gear oil). A lower ratio pump may be required to reduce system pressure and maintain sufficient flow.

309497L

35

Image 35
Contents Matrix Meter Manual Conventions ContentsSkin Injection Hazard Meter Programming Programming the MeterProgramming the Meter DESCRIPTION, See F IG Meter InstallationDESCRIPTION, See FIG Mounting BracketsGrounding Pressure Relief ProcedurePre-installation Procedure Pressurizing the System Installing Nozzle ExtensionMeter Installation to Hose Meter Operation Asleep / Awake ModeHigh/Low Flow Rate Indicator Battery Life IndicatorPIN Code Parts Room AuthorizationSecurity Modes System Monitoring32567 IC9 2AC03 458A1 2233A Work Orders and Job NumbersAssigning Work Orders and Job Numbers from the PC Assigning Work Orders and Job Numbers at the Meter1222 Emergency ModePlacing a Meter in the Emergency Mode Dispense Options Preset Dispense ModeManual Dispense Mode Nozzle opens and closes with Less than one turn Restricted Preset Dispense ModeRemoving and Replacing the Battery Quick-LockNozzleFlow. Warning do not exceed the maximum working TroubleshootingProblem Cause Solution FicationsPressure of the meter 1500 psi 103 bar. If flushing Problem Cause Solution Measurement Calculating the Calibration FactorMetric Measurement 309497L Replacing Quick-lockNozzle ServiceReplacing or Cleaning Filter Follow the Pressure Relief Procedure, page 8, whenever youReplacing the Bezel Service Replacing the Trigger Relieve the Pressure Ti4323 Service Replacing the Meter Electronics Service Service Service Parts Drawing for the 246008 and 249881 Electronic Meters Description Qty Parts List for the 246008 and 249881 Electronic MetersDescription Nozzle Extension AccessoriesKit QtyTechnical Specifications 309497L Dimensions Graco Phone Numbers Graco Standard Warranty