Graco 246008 Installing Nozzle Extension, Meter Installation to Hose, Pressurizing the System

Page 9

Installing Nozzle Extension

1.Slide the impact guard (40) onto the tube or hose of the nozzle extension assembly. See FIG. 7.

2.Thread the sealing nut (101, 204, or 303) onto the spout (102, 202, or 302).

3.Thread the tube or hose in at least three full turns, position it for proper alignment, and wrench tighten the sealing nut. The PTFE seal on the sealing nut must face the valve housing. See FIG. 7.

4.Slide the impact guard (40) over the meter body.

101, 204, or 303

Programming the Meter

CAUTION

Graco recommends using PTFE tape on hose threads prior to installing the Matrix meter. PTFE tape should be after the leading thread and clockwise (same direc- tion as meter installs on hose fitting). Caution should be taken not to get tape into the meter during installa- tion as this can cause the meter to malfunction. Should the tape be the cause of the malfunction, Graco warranty will be denied.

2.Apply PTFE tape to the male threads of the hose fit- ting (P). See caution above. Leave a minimum of two engaged threads bare to maintain grounding continuity.

102, 202, or 302

wrench tighten to 40 prevent leakage

P

24 1

29

FIG. 7

Meter Installation to Hose

1. Slide the rear boot (24) onto the hose. See FIG. 8.

WARNING

Improper grounding can cause a hazardous condition and result in fire or explosion. Follow instructions in step 2 to maintain grounding continuity.

1 Slide boot onto

 

hose before connecting hose

ti64317

FIG. 8

3.Thread the hose fitting into the swivel (29) of the meter, and tighten it firmly. See FIG. 8.

4.Slide the rear boot (24) over the fittings and onto the end of the Matrix meter.

Pressurizing the System

1.Open all dispense position shut-off valves. Start the pump to pressurize the system. See the Operation section, page 14, for proper operation of meter.

2.To ensure dispensing accuracy, purge all air from the fluid lines and dispense valve before using it.

3.Set the system flow to the desired flow rate, which is typically 1.5-gpm. Do not exceed a 5-gpm flow rate.

309497L

9

Image 9
Contents Matrix Meter Manual Conventions ContentsSkin Injection Hazard Meter Programming Programming the MeterProgramming the Meter DESCRIPTION, See F IG Meter InstallationDESCRIPTION, See FIG Mounting BracketsPressure Relief Procedure Pre-installation ProcedureGrounding Installing Nozzle Extension Meter Installation to HosePressurizing the System High/Low Flow Rate Indicator Asleep / Awake ModeBattery Life Indicator Meter OperationSecurity Modes Parts Room AuthorizationSystem Monitoring PIN CodeAssigning Work Orders and Job Numbers from the PC Work Orders and Job NumbersAssigning Work Orders and Job Numbers at the Meter 32567 IC9 2AC03 458A1 2233AEmergency Mode Placing a Meter in the Emergency Mode1222 Preset Dispense Mode Manual Dispense ModeDispense Options Removing and Replacing the Battery Restricted Preset Dispense ModeQuick-LockNozzle Nozzle opens and closes with Less than one turnProblem Cause Solution TroubleshootingFications Flow. Warning do not exceed the maximum workingPressure of the meter 1500 psi 103 bar. If flushing Problem Cause Solution Calculating the Calibration Factor Metric MeasurementMeasurement 309497L Replacing or Cleaning Filter ServiceFollow the Pressure Relief Procedure, page 8, whenever you Replacing Quick-lockNozzleReplacing the Bezel Service Replacing the Trigger Relieve the Pressure Ti4323 Service Replacing the Meter Electronics Service Service Service Parts Drawing for the 246008 and 249881 Electronic Meters Description Qty Parts List for the 246008 and 249881 Electronic MetersKit Nozzle Extension AccessoriesQty DescriptionTechnical Specifications 309497L Dimensions Graco Phone Numbers Graco Standard Warranty