Graco 246008, 249881 Service, Replacing or Cleaning Filter, Replacing Quick-lockNozzle

Page 21

Service

WARNING

Read warnings, page 3.

Follow the Pressure Relief Procedure, page 8, whenever you:

are instructed to relieve pressure

stop operation

check, clean, or service any of the equipment

The low-battery and dead-battery displays are explained in the Troubleshooting chart on page 16.

To change the battery see Removing and Replacing the Battery on page 15.

Replacing or Cleaning Filter

To replace or clean the filter, do the following:

1.Relieve the pressure.

2.Unscrew the hose from the swivel (29). See FIG. 22.

3.Remove the o-ring (6), and remove the filter (9) from its seat in the swivel (29) with an o-ring pick.

4.Thoroughly clean the filter with solvent, or replace with the new filter.

5.Push the new or cleaned filter (9) into the swivel (29), and make sure it’s properly seated. Replace the o-ring (6).

Be sure to position the new filter (9) so the concave side of the screen points downstream. See FIG. 22.

6. Screw the hose back into the swivel (29).

Service

29

6 9

 

 

 

 

m

 

 

 

a

 

 

e

 

 

r

 

 

 

t

 

 

s

 

 

 

n

 

 

 

 

w

 

 

 

 

o

 

 

 

 

D

 

 

 

 

ti64320

FIG. 22

Replacing Quick-lockNozzle

The quick-lock nozzle (101, 201, or 301) is not service- able. If the nozzle leaks, replace it as follows. See FIG. 23.

1.Remove the old nozzle from the extension with an open-end adjustable wrench on the flats (A) of the nozzle stem.

2.Thread the new nozzle (101, 201, or 301) onto the extension. With an open-end adjustable wrench on the flats (A) of the nozzle stem, firmly tighten the nozzle. the flats (A) of the nozzle stem, firmly tighten the nozzle.

101

ti64328A

A

201 ti64329

A

301

ti64330

FIG. 23

309497L

21

Image 21
Contents Matrix Meter Manual Conventions ContentsSkin Injection Hazard Meter Programming Programming the MeterProgramming the Meter DESCRIPTION, See F IG Meter InstallationDESCRIPTION, See FIG Mounting BracketsPressure Relief Procedure Pre-installation ProcedureGrounding Installing Nozzle Extension Meter Installation to HosePressurizing the System High/Low Flow Rate Indicator Asleep / Awake ModeBattery Life Indicator Meter OperationSecurity Modes Parts Room AuthorizationSystem Monitoring PIN CodeAssigning Work Orders and Job Numbers from the PC Work Orders and Job NumbersAssigning Work Orders and Job Numbers at the Meter 32567 IC9 2AC03 458A1 2233AEmergency Mode Placing a Meter in the Emergency Mode1222 Preset Dispense Mode Manual Dispense ModeDispense Options Removing and Replacing the Battery Restricted Preset Dispense ModeQuick-LockNozzle Nozzle opens and closes with Less than one turnProblem Cause Solution TroubleshootingFications Flow. Warning do not exceed the maximum workingPressure of the meter 1500 psi 103 bar. If flushing Problem Cause Solution Calculating the Calibration Factor Metric MeasurementMeasurement 309497L Replacing or Cleaning Filter ServiceFollow the Pressure Relief Procedure, page 8, whenever you Replacing Quick-lockNozzleReplacing the Bezel Service Replacing the Trigger Relieve the Pressure Ti4323 Service Replacing the Meter Electronics Service Service Service Parts Drawing for the 246008 and 249881 Electronic Meters Description Qty Parts List for the 246008 and 249881 Electronic MetersKit Nozzle Extension AccessoriesQty DescriptionTechnical Specifications 309497L Dimensions Graco Phone Numbers Graco Standard Warranty