Hoshizaki MRH KM-600MAH KM-650MAH, MWH KM-515MAH, MRH/3, MRH KM-901MAH, MWH(-M), KM-320MAH

Models: KM-320MAH MRH KM-600MAH KM-650MAH MWH(-M) MRH KM-901MAH MRH/3 MWH KM-515MAH MWH

1 94
Download 94 pages 41.69 Kb
Page 75
Image 75

3. KM-515MAH

APPROXIMATE ICE

AMBIENT TEMP.

 

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

 

70/21

 

 

90/32

 

 

 

 

70/21

 

501

227

 

482

218

 

447

203

 

 

 

 

80/27

 

486

221

 

456

207

 

416

189

lbs./day

 

kg./day

90/32

 

482

218

 

435

197

 

396

180

 

100/38

 

472

214

 

426

193

 

361

164

 

 

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

980

 

 

 

1012

 

 

1038

CONSUMPTION

80/27

 

1005

 

 

 

1055

 

 

1071

 

 

 

 

90/32

 

1012

 

 

 

1090

 

 

1111

watts

 

 

 

100/38

 

1011

 

 

 

1095

 

 

1130

APPROXIMATE WATER

70/21

 

188

0.71

 

162

0.61

 

147

0.56

CONSUMPTION PER 24 HR.

80/27

 

168

0.64

 

128

0.48

 

124

0.47

 

 

m3/day

90/32

 

162

0.61

 

99

0.38

 

90

0.34

gal./day

 

100/38

 

132

0.50

 

97

0.37

 

82

0.31

FREEZING CYCLE TIME

70/21

 

26

 

 

 

27

 

 

30

 

 

 

 

80/27

 

27

 

 

 

30

 

 

33

 

 

 

 

90/32

 

27

 

 

 

32

 

 

35

min.

 

 

 

100/38

 

28

 

 

 

33

 

 

37

HARVEST CYCLE TIME

70/21

 

4.4

 

 

 

3.9

 

 

3.8

 

 

 

 

80/27

 

4.0

 

 

 

3.2

 

 

3.4

 

 

 

 

90/32

 

3.9

 

 

 

2.7

 

 

2.7

min.

 

 

 

100/38

 

3.4

 

 

 

2.7

 

 

2.7

HEAD PRESSURE

70/21

 

226

15.9

 

250

17.6

 

278

19.5

 

 

 

 

80/27

 

244

17.2

 

282

19.8

 

306

21.5

 

 

 

 

90/32

 

250

17.6

 

308

21.7

 

335

23.5

PSIG

kg/cm2G

100/38

 

254

17.8

 

314

22.1

 

359

25.2

SUCTION PRESSURE

70/21

 

45

3.2

 

49

3.5

 

54

3.8

 

 

 

 

80/27

 

48

3.4

 

55

3.8

 

60

4.2

 

 

 

 

90/32

 

49

3.5

 

59

4.1

 

64

4.5

PSIG

kg/cm2G

100/38

 

50

3.5

 

60

4.2

 

69

4.9

TOTAL HEAT OF REJECTION FROM CONDENSER

 

9,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

Note:

1.Pressure data is recorded at 5 min. into freezing cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.

75