2. "G" Control Board

At startup, a 5-second delay occurs while the control board conducts an internal timer check. A beep occurs when the control switch is moved to the "ICE" position. The red "POWER OK" LED indicates proper control voltage and remains on unless a control voltage problem occurs. The green LEDs 1 through 4 energize and sequence from initial startup as listed in the table below. Note that the order of the LEDs from the outer edge of the control board is 1, 4, 3, 2.

 

Sequence Step

 

 

LED

 

 

Energized

 

 

 

 

 

Time LEDs are On

 

 

 

 

 

Components

 

 

Min.

 

 

Max.

 

 

Avg.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-Minute Fill Cycle

 

4

 

 

WV

 

 

 

 

 

 

 

 

1 minute

 

Harvest Cycle

 

 

1, 4, 2

 

 

Comp, FMR, HGV, WV

 

 

2 minutes

 

 

20 minutes

 

 

3 to 5 minutes

 

 

Harvest Pump Timer

 

1, 3, 2

 

 

Comp, FMR, HGV, PM

 

 

0 seconds

 

 

50 seconds

 

 

harvest pump timer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

setting

 

Freeze Cycle

 

1

 

 

Comp, FM/FMR, PM,

 

 

5 minutes

 

 

freeze timer

 

 

30 to 35 minutes

 

 

 

 

 

 

 

LLV

 

 

 

 

 

setting

 

 

 

 

 

Pump-Out Cycle

 

 

1, 4*, 3, 2

Comp, FMR, HGV, PM,

 

 

10 seconds

20 seconds

 

 

*pump‑out timer

 

 

 

 

 

 

 

WV*

 

 

 

 

 

 

 

 

setting

The built-in safeties shut down the icemaker and have alarms as listed below.

No. of Beeps

Type of Alarm

Notes

(every 3 sec.)

 

 

1

High Evaporator Temp.

Check for harvest problem (stuck HGV or relay), hot

 

(temperature > 127°F) (53°C)

water entering icemaker, or shorted thermistor.

2

Harvest Backup Timer

Check for open thermistor, HGV not opening, TXV or

 

(harvest > 20 min. for two

LLV leaking by, low charge, or inefficient Comp, or WRV

 

cycles in a row)

leaking by.

3

Freeze Timer

Check for FS stuck closed (up), WV leaking by, HGV

 

(freeze > freeze timer setting

leaking by, PM not pumping, TXV not feeding properly,

 

for two cycles in a row)

LLV not opening, low charge, HM not bypassing, or

 

 

inefficient Comp.

To reset the above safeties, press the "ALARM RESET" button with the power supply on.

6

Low Voltage

Red LED turns off if voltage protection operates.

 

(92Vac±5% or less)

The control voltage safeties automatically reset when

7

High Voltage

voltage is corrected.

 

(147Vac±5% or more)

 

Legend: Comp–compressor; FM–fan motor; FMR–fan motor remote; FS–float switch; HGV–hot gas valve; HM–headmaster (C.P.R.); LLV–liquid line valve; PM–pump motor; TXV–thermostatic expansion valve; WRV–water regulating valve; WV–inlet water valve

45

Page 45
Image 45
Hoshizaki MRH KM-901MAH, MWH KM-515MAH, MRH/3, MWH(-M), MRH KM-600MAH KM-650MAH, KM-320MAH service manual G Control Board