Hoshizaki MRH KM-600MAH KM-650MAH, MWH Low Ice Production - Possible Cause, Long Freeze Cycle

Models: KM-320MAH MRH KM-600MAH KM-650MAH MWH(-M) MRH KM-901MAH MRH/3 MWH KM-515MAH MWH

1 94
Download 94 pages 41.69 Kb
Page 40
Image 40
Long Freeze Cycle

Low Ice Production - Possible Cause

 

 

Long Freeze Cycle

 

 

 

1.

Evaporator

a) Scaled up, dirty.

2.

Float Switch

a) Scaled up, dirty.

 

See "II.E. Float Switch Check

 

 

b) Float sticking.

 

and Cleaning"

 

 

 

c) Defective switch.

 

 

 

 

3. Inlet Water Valve

a) Leaking by.

4. Hot Gas Valve

a) Erratic or open.

 

 

5. Condenser

a) Clogged.

 

 

6. Control Board

a) Float switch connection loose (K5).

 

See "II.C. Control Board Check"

 

 

b) Defective.

7. Refrigerant Charge

a) Low.

 

 

8. Thermostatic Expansion Valve

a) Bulb loose.

 

 

 

 

 

b) Defective.

 

 

 

9.

Compressor

a) Inefficient or off.

10. Pump Motor

a) RPM too slow.

 

 

 

11.

Liquid Line Valve

a) Erratic or restricted.

 

 

12. Headmaster (C.P.R.)

a) Not bypassing.

 

(remote models)

 

 

 

 

40

Page 40
Image 40
Hoshizaki MRH KM-600MAH KM-650MAH, MWH KM-515MAH, MRH/3, MWH(-M) Low Ice Production - Possible Cause, Long Freeze Cycle