C. Settings and Adjustments

C. Settings and Adjustments

NOTICE

Dip switches are factory set. Failure to maintain factory settings may adversely affect performance and warranty coverage. For more information, contact your Hoshizaki Service Center.

1. Default Dip Switch Settings

The dip switches are factory-adjusted to the following positions for both the "E" and "G" control boards:

a) "E" and "G" Control Board without Harvest Pump Timer Operation

"E" Control Board S4 Dip Switch No.

1

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

KM-320MAH, KM-320MWH

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

KM-515MAH, KM-515MWH, KM-515MRH

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

KM-600MAH, KM-650MAH, KM-650MWH

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

KM-650MRH

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

KM-901MAH, KM-901MWH, KM-901MRH/3

ON

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

b) "G" Control Board with Harvest Pump Timer Operation

S4 Dip Switch No.

 

 

 

 

 

1

 

2

3

4

5

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KM-515MAH

 

 

 

 

 

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KM-650MAH, KM-650MRH

ON

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

KM-650MWH(-M)

 

 

 

 

 

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KM-901MAH

 

 

 

 

 

OFF

OFF

ON

OFF

ON

ON

ON

OFF

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S5 Dip Switch (Do Not Adjust)

 

 

 

 

 

 

 

 

 

 

 

"G" Control Board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dip Switch No.

 

1

2

3

4

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All Models

 

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S4 Dip Switch

"E" and "G" Control Boards

 

 

 

 

 

 

 

Freeze Timer (9 & 10)

 

 

 

 

 

 

10

 

 

 

 

Factory Use (8)

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bin Control Selector (7) "E" Control Board

 

 

 

 

 

 

8

 

 

 

 

 

 

 

Harvest Pump Timer (7) "G" Control Board

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

6

(Do Not Adjust)

 

 

 

 

 

5

 

 

 

 

 

Pump-Out Frequency Control (5 & 6)

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Pump-Out Timer (3 & 4)

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

1

Harvest Timer (1 & 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S5 Dip Switch

"G" Control Board Only

Do Not Adjust

 

 

 

 

 

 

5

Refill Counter

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

3

(2 through 5)

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

1

Float Switch

 

 

 

 

 

 

 

 

 

 

 

Selector (1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 