Hoshizaki KM-320MAH, MWH KM-515MAH, MRH/3, MWH(-M) Pump-Out Frequency Control S4 dip switch 5

Models: KM-320MAH MRH KM-600MAH KM-650MAH MWH(-M) MRH KM-901MAH MRH/3 MWH KM-515MAH MWH

1 94
Download 94 pages 41.69 Kb
Page 48
Image 48
4. Pump-Out Frequency Control (S4 dip switch 5 & 6)

4. Pump-Out Frequency Control (S4 dip switch 5 & 6)

NOTICE

Do not adjust on KM-515M_H without harvest pump timer. Adjustments to this setting on KM-515M_H without harvest pump timer may adversely affect performance and warranty coverage.

The pump-out frequency control is factory set to drain the water tank every 10 cycles on all KM-320M_H, KM-600MAH, KM-650M_H, KM-901M_H/3 and on KM-515MAH with harvest pump timer, and every cycle on KM-515M_H without harvest pump timer. Generally no adjustment is required. However, where water quality is bad and the icemaker needs a pump-out more often, the pump‑out frequency can be adjusted. The pump-out frequency control can be set to have a pump‑out occur every cycle, or every 2, 5, or 10 cycles.

Timing of the first pump-out is dependent on the control board. On "E" control boards, the first pump‑out is after the first freeze cycle. On "G" control boards, the first pump-out is dependent on S4 dip switch 5 & 6. See the table below.

 

"E" & "G" Control Board

1st Pump-Out

 

 

 

 

 

S4 Dip Switch Setting

Pump-Out

"E" Control Board

"G" Control Board

No. 5

 

No. 6

Frequency

 

 

 

OFF

 

OFF

Every cycle

After 1st freeze cycle

After 2nd freeze cycle

 

 

 

 

 

 

ON

 

OFF

Every 2 cycles

 

After 3rd freeze cycle

 

 

 

 

 

 

OFF

 

ON

Every 5 cycles

 

After 6th freeze cycle

 

 

 

 

 

 

ON

 

ON

Every 10 cycles

 

After 11th freeze cycle

5.Bin Control Selector or Harvest Pump Timer Operation (S4 dip switch 7) Depending on the control board, S4 dip switch 7 is used for either bin control selection or harvest pump timer operation.

(1) Bin Control Selector, "E" Control Board

NOTICE

Do not adjust. This dip switch must be left in the factory default position or the icemaker will not operate correctly.

When set to on position on an icemaker with a thermostatic bin control, a 5-beep alarm sounds (open circuit) and the icemaker does not operate.

 

"E" Control Board

S4 Dip Switch Setting

Bin Control

 

No. 7

 

 

 

ON

Mechanical (requires resistor wire harness)

 

 

OFF

Thermostatic

48

Page 48
Image 48
Hoshizaki KM-320MAH, MWH KM-515MAH Pump-Out Frequency Control S4 dip switch 5, Bin Control Selector, E Control Board