Furuno FSV-30S Control Unit, Mounting procedure, Processor unit, Rubber feet

Page 15

Mounting procedure

1.Unfasten two bolts from the bottom of the front side of the processor unit. Pull the unit toward you to separate it from the mounting base.

2.Use six bolts (M620, supplied as installation material) to fix the mounting base.

3.Place the processor unit in front of the mounting base.

4.Push the unit forward until it touches the end of the mounting base.

5.Refasten two bolts removed at step 1 to fix the unit to the mounting base.

504

5.5477

160+1

 

34

8

 

200+1 195+1

Front view

Top view

Processor unit

1.3 Control Unit

The control unit may be mounted on a tabletop with or without the KB (keyboard) fixing plate (supplied), which mounts the control unit at an angle. If the control unit is not to be fixed permanently, lay it atop the rubber feet (supplied as accessories). Be sure to observe the compass safe distances noted on page ii to prevent interference to a magnetic compass.

(1) Rubber feet

Attach four rubber feet to the bottom of the control unit if it is not going to be permanently fixed.

1-9

Image 15
Contents Color Scanning Sonar 00014857415 Safety Instructions Projected Raising Lowering Mm stroke Max kt Iii System ConfigurationOptional Equipment Standard supplyHull Unit Mounting considerationsHull unit mounting location Maintenance space, example sonar compartment Guidelines for shortening the retraction tank Shortening the retraction tankHow to install reinforcement ribs Remarks for installation of retraction tankInstalling hull unit on retraction tank Installation of hull unit Installing stays anti-vibration measure Proper installation of staysProper and improper stay installation methods Processor Unit Mounting considerationsProcessor unit, rear view Rubber feet Mounting procedureControl Unit Processor unitMounting with KB fixing plate How to attach KB fixing plateMounting without KB fixing plate Control unitControl unit, side view Control unit, cover removedTransceiver unit, junction box Use copper strap supplied Transceiver UnitGrounding the Equipment Transceiver unitInstalling the Attachment Flange option ProcedureAttachment flange Type OP10-27, Code no Junction box Cable Extension Kit optionAttachment kit Type OP10-24, Code no Installing the Attachment Kit optionInstallation of attachment kit Crimping tool, contact pin, pin extractor How to Use the Crimping Tool, Pin ExtractorHow to use the crimping tool How to use the pin extractorWiring WiringTransceiver unit side Cable type 10S1258-1, sectional view 1 10S1258-1 cablePositioning guide pins Fabrication of connector 00-8016-038-313761HV CN-A101Fabrication of cable for connector 00-8016-038-313761HV Assembling 38P connectorPower cable Assembling connector NCS-253-PControl cable Sectional view of cables Cable listGyro For voltage driven KP 12 V input Menu settingSynchronizing with echo sounder or other sonar For current driven KP inputFabrication of cable for 00-8016-038-313761HV Fabrication of connector 00-8016-038-313761HV CN-B101CN-B101 CN-B102 Transceiver unit, inside viewFabrication of power cable type DPYCYS-2.5 TB-B101 Hull control cable 10S2078Fabrication of cable type DPYCYS-2.5 Transceiver unit, top view Wiring in transceiver unitCable Extension Kit Junction boxJunction box, cover removed Signal cable 10S2240 connects to Junction BOX display side Raise/lower control box, cover removed Raise/Lower control boxPower cable fabrication Marking the label Input Voltage and FusesInput voltage FusesHull Unit Check Main menuOthers menu Test menu Initial Setting menuHow to check the hull unit Transducer switches of the control unitControl unit in hull unit Page Heading Adjustment Heading adjustmentSystem menu Others menu, Heading Adjust Configuring Own Ship Mark OWN Ship Mark menu, setting windowOWN Ship Mark menu Ship shape description Interface Setting menu Interface Setting menuOther System Menu Items EXT Data Setting menu EXT Data Setting menuData sentences Nmea 0183, Furuno proprietary ES Draft Offset Others menuCone Board Setting in the Processor Unit Adjustment of signal level echo sounder connectedAdjusting the volume of the audio alarm Ifes Board 10P6983 DIP Switch Setting1 CIF2/NMEA2 connector interface selection Processor unit, inside viewChoosing echosounder signal This page intentionally left blank Processor unit, front view Name Type Code No Qty RemarksGND Wiring between processor unit and CS-120ADcon Board 10P6984 or 10P6984A This page intentionally left blank Packing List FSV-301 58 58 58 58 58 付属品表 52#42#465.+5614 52 Page Page Page Hatai Hatai Hatai Hatai Hatai Page Page This page is intentionally left blank Color Scanning Sonar Miyosi